Decision Table — Q-21699 (Saipem COMP2)

Req_IDRequirement (verbatim or paraphrase with citation)StatusOffer_Evidence_DocOffer_Page_or_LineEP Item_IDNotes
R-IP-001Outdoor equipment shall be IP66; splash zone IP67 (200-51-IN-SPC-00021_00, lines 1721–1725)RFIEP‑009RFI‑IP issued to request IP certificates for JB/sign box/chiller
R-HAZ-001ATEX Zone 1/2, IIA/IIB T3; IIC available; non‑flameproof models available (Datasheets and CoCs.md, lines 212–218; 468–471)Partially CompliantDatasheet with GA - EXP‑MH‑14KS-1500212–218; 468–471EP‑002Variant locked: FLP, Protection Concept Ex d per spec 6.4 (200-51-IN-SPC-00021_00, lines 1771–1780). Certificates pending (RFI‑FLP/BOM).
R-PWR-001Electrical supply 240 V 1Ph 50/60 Hz; heater 3 kW @ 230 V (Datasheets and CoCs.md, lines 216–219); Spec packages 230 Vac UPS (200-51-IN-SPC-00021_00, lines 2020–2049)Decision: Include TransformerDatasheet with GA - EXP‑MH‑14KS-1500216–219Decision (b): Include FLP Ex d step‑down transformer 240→230 Vac sized for 3 kW heater; feed from 230 Vac UPS per spec (lines 2020–2049). Link CPQ row to Req_ID R‑PWR‑001.
R-FLOW-001Shower 76 L/min; Eye/face wash 12 L/min; EN/ANSI (Datasheets and CoCs.md, lines 224–227)CompliantDatasheet with GA - EXP‑MH‑14KS-1500224–227EP‑002Meets EN/ANSI minima
R-EMC-001Provide EMC/EMI declaration; ATEX/IECEx equipment register referenced not attached (Quality Documents.md, lines 741–742; 751–752)RFIEP‑007; EP‑008RFI‑EMC issued to request declarations and registers