Infinity

Not logged in
Home

❯

Reference Examples

❯

Q 31108 Tecnicas Riyas

❯

Wiring Diagram Marjan

CONTRACTOR PROJECT No.

10230

PO No. 1023009110

CONTRACTOR Doc. Code

ESQ-0007

CONTRACTOR Document Number

V-1023009110-0009

REV. F MARJAN INCREMENT PROGRAM - TANAJIB GAS PLANT PROJECT, PK-09 & 11

VENDOR NAME / LOGO

DOCUMENT TITLE

WIRING DIAGRAM

NMR Code

602

UNIT / EQUIPMENT No.

VENDOR DOCUMENT No.

VENDOR REV. F

111962-D01

REVIEW RESPONSE BY CONTRACTOR:

CONTRACTOR review comments do not indicate either responsibility or liability for accuracy and completeness of this Document or alter any contractual terms and conditions.

A - REJECTED

     C - REVI EWED WITH COMMENTS

    F - REVIEWED  WITHOUT COMMENTS

B - COMMENTS AS NOTED

R - REVIEWED AS BUILT

I - FOR INFORMATION

REVIEW DATE :

FOR INFORMATION ONLY PROVIDED AS A REFERENCE FOR RIYAS RFQ: 106510911

10230-00-082-PD-0003-TMP01

This document is property of UTE TR Marjan and TR Saudia for Services and Contracting Co Ltd. Its reproduction without previous permission in writing is strictly forbidden.

0 5

2 6 9 1 1 1

: .

O N

.

G W D

JUNCTION BOX FOR LOCAL & REMOTE ALARM WITH TAGGING BELOW, TXX-SSEW-LP-XXXX TXX-EW-LP-XXXX WHERE “XX” AND “XXXX” SHALL MATCH WITH SAFETY SHOWER OR EYE WASH TAG NUMBER. DETAIL PLEASE REFER TO TAGGING LIST

JUNCTION BOX FOR PHOTOCELL LIGHT CONTROL WITH TAGGING BELOW, TXX-SSEW-XXXX-JB TXX-EW-XXXX-JB WHERE “XX” AND “XXXX” SHALL MATCH WITH SAFETY SHOWER OR EYE WASH TAG NUMBER. DETAIL PLEASE REFER TO TAGGING LIST

M20 EX CERTIFIED STOPPING PLUG (SPARE)

M20 EX CERTIFIED STOPPING PLUG (SPARE)

ENCAPSULATED CONTROL CIRCUIT

E N

GL

NY

Ls E

EARTH

PHOTOCELL HEAD

REFERENCE DRAWING

DWG. NO.

NOTES:

JUNCTION BOX 1 TYPE: ABTECH BPG 9 &, GRP ENCLOSURE ATEX/IECEx CERTIFIED, II 2G EXe II T5, IP66 AMBINET TEMPERATURE: -65C TO +130C SUPPLY WITH LOOSE 2 X M20(MALE) TO NPT 3 / 4”(FEMALE) ADAPTOR FOR CLIENT CONNECTION. M20 EX CERTIFIED STOPPING PLUG FITTED AT L.H.S. & R.H.S. ALL TERMINAL BLOCKS ARE SUITABLE FOR 6mmsq CABLE

JUNCTION BOX 2 TYPE: ABTECH BPG &, GRP ENCLOSURE ATEX/IECEx CERTIFIED, II 3 GD Ex nA mc IIC T6 Gc, Ex tc IIIC T80ºC Dc, IP66 AMBINET TEMPERATURE: -40°C to 55°C

JUNCTION BOX 3 TYPE:

The Ex Zone ATEX/IECEx CERTIFIED, II3 G Ex ec nC IIC T4, IP66 AMBINET TEMPERATURE: -20°C to 55°C

FLOW SWITCH TYPE:

Type FF61 ‘Perseus’ Series Flameproof 1-1/4 INCH NPT FF60 STAINLESS STEEL FLOW SWITCH WITH M20X1.5 TERMINAL BOX, DPDT CONTACTS FF62SB/AT020012/41XB ATEX/IECEx CERTIFIED, II 2G Ex db IIC T6….T5 Gb (Tamb -50 to +75°C T6 / -50°C to +90°C T5)

LOCAL ALARM TYPE:

24 VDC E2S BEXCS11005DPRDC024AB1A1R/R AUDIBLE/VISUAL ALARM IP66 ATEX/IECEx CERTIFIED, II 2G Ex db IIB T5 Gb Ta. -50°C to +40°C

TAGGING:

PLEASE REFER TO THE TAGGING LIST

  1. CABLE GLAND

7.1.

7.2.

M20 NICKEL PLATED BRASS CCH CAPRI ADE 5F-20-5 CABLE GLAND WITH PVC SHROUD(UNLESS SPECIFIED, OTHERWISE ALL CABLE GLANDS PROVIDE WITH THIS TYPE) M20 HAWKE NICKEL PLATED BRASS ICG/653/0S UNIVERSAL BARRIER GLAND WITH PVC SHROUD

M20(MALE) TO 3/4NPT(FEMALE) ADAPTORS

3/4NPT CABLE GLAND BY CLIENT

EARTH

1

2 3

4

5

6

7

E

E E E E

8 9 10 11

12

13

1 0

S T

2 0

S T

M20

M20

M20

M20

M20

M20

5CX1.5mm²

3CX1.5mm²

M20 BREATHER AND DRAIN

M20

M20

3CX1.5mm²

L A R T U E N

H T R A E

E V I L

3/4NPT CABLE GLAND BY CLIENT

230VAC-1P-60HZ FROM CLIENTS POWER SUPPLY CABLE&GLAND BY CLIENT LIVE NEUTRAL EARTH

M20(MALE) TO 3/4NPT(FEMALE) ADAPTORS

JUNCTION BOX FOR STEP DOWN TRANSFORMER WITH TAGGING BELOW, TXX-SSEW-JB1-XXXX TXX-EW-JB1-XXXX WHERE “XX” AND “XXXX” SHALL MATCH WITH SAFETY SHOWER OR EYE WASH TAG NUMBER. DETAIL PLEASE REFER TO TAGGING LIST

E +V

-V

M20

L A R T U E N

H T R A E

E V I L

L A R T U E N

H T R A E

E V I L

N W O R B

H T R A E

E U L B

N W O R B

H T R A E

E U L B

M20

)

D E S O L C N

/

(

6

)

N O M M O C

(

5

)

D E S O L C N

/

(

3

)

N E P O N

/

(

4

)

N O M M O C

(

2

)

N E P O N

/

(

1

)

H T R A E

(

FOR DCS ALARM

FOR LOCAL ALARM

FLOW SWITCH

FF-WD-A3.DWG

N R U T E R

H T R A E

D E E F

230VAC TO 24VDC STEP DOWN TRANSFORMER

EARTH

E N L

    • E

M20

M20

M20 BREATHER AND DRAIN

F

E

D

C

B

A

16.01.24

AS BUILT

03.11.23

ISSUED FOR COMMENT

05.09.23

ISSUED FOR COMMENT

02.08.23

ISSUED FOR COMMENT

22.05.23

ISSUED FOR COMMENT

31.01.23

ISSUED FOR APPROVAL

T.C A.L A.L J.H

T.C A.L A.L J.H

T.C A.L A.L J.H

T.C A.L A.L J.H

T.C P.H P.H J.H

T.C P.H J.H J.H

REV.

ISSUE

DATE

OWNER :

PROJECT :

DESCRIPTION

DWN. BY

APPR. BY

CHKD. BY DISCIPLINE

APPR. BY

PROJ.

Whitefield Road, Bredbury Stockport, Cheshire, SK6 2SS

T: +44(0)161-430-6618 F: +44(0)161-430-7928 E: info@hughes-safety-showers.co.uk

E L O H W E H T R E H T E N

I

.

R E N W O E H T O T D E V R E S E R S T H G R L L A D N A L A T N E D F N O C S

I

I

I

TITLE :

WIRING DIAGRAM FOR SAFETY SHOWER EXP-SD-18GS/85G & EXP-SD-85GS/P SUITABLE FOR HAZARDOUS AREAS

SCALE :

N.T.S

SHEET :

1

OF

1

OWNER PROJECT NO.:

PROJECT NO.:

111962

DRAWING NO.:

111962-50

CAD REF. :

\DRAWINGS\AMENDED

I

T

I

.

S E H G U H F O Y T R E P O P E H T S

I

T N E M U C O D S H T

I

REV.

F

R O M E T S Y S L A V E R T E R Y N A N

I

I

D E R O T S

,

D E C U D O R P E R

,

I

I

Y T R A P D R H T Y N A O T D E S O L C S D E B Y A M T N E M U C O D S H T F O T R A P Y N A R O N

I

.

S E H G U H F O T N E S N O C N E T T R W R O R P E H T T U O H T W

I

I

I

,

S N A E M Y N A R O F M R O F Y N A N

I

I

D E T T M S N A R T

Project: Q-31108 - Tecnicas - Riyas Folder: Project Root


Loading authentication...

Graph View

Backlinks

  • Index - Q-31108 - Tecnicas - Riyas

Created with Infinity Constructor © 2025

  • Elynox | Go Further