Infinity

Not logged in
Home

❯

Reference Examples

❯

Q 32705 Saipem COMP3

❯

RFQ Files

❯

265 83 SH PLN 00001_A

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Classification: Internal

1

PLATFORM NORTH

30°

30°

N

E H U T R R T O N

E H U T R R T O N

PREVAILING WIND

N. 122,250

3

0 5 2 8

265-XZ8311

XXX-XZXXXX (HOLD-1)

BAM 6

N. 114,000

2

XXX-FEXXXX (HOLD-1)

9 Kg

A

0 0 0 0 0 1

,

.

E

B

0 0 0 5 1 1

,

.

E

265-XZ8310

15000

T.O.S. EL.+12700

15000

TO PRODUCTION DECK

) T 1 (

8 2 0 2 B X

5 6 2

0 0 9 3 1 + . L E S O B

.

.

) T 1 (

7 2 0 2 B X

5 6 2

UP

UP

)

N 3 1 L P

(

N 6 P R O T R E S R

I

” 8 2

I

E T S O P M O C R O F E B U T

J

” 2 1

M O R F E L B A C

3 1 P H W O T N 6 P R

E R U T U F O T

M R O F T A L P N O S S E R P M O C

I

I

E N I L E P P D L E F A R T N

I

I

” 8 2

0 0 9 3 1 + . L E S O B

.

.

T.O.S. EL.+9500

DN

TO JACKET LEVEL

265-P9301B

265-P9301A

265-US-06

T.O.S. EL.+12400

265-T8701

SSJB-265601

WELLSLOT#01 WELLSLOT#02 WELLSLOT#03

(SPARE)

265-S9301

C

0 0 0 0 3 1

,

.

E

1 0 4 9 P

5 6 2

0 0 0 4 1

WELLSLOT#04 WELLSLOT#05

(SPARE)

WELLSLOT#06 (SPARE)

265-H8701

A 2 0 7 8 P

5 6 2

B 2 0 7 8 P

5 6 2

1 0 7 8 Y

5 6 2

265-V8701

4 0 7 8 P

5 6 2

3 0 7 8 P

5 6 2

N. 100,000

1

MAX.CRANE RADIUS 35m

WELLSLOT#07 WELLSLOT#08 WELLSLOT#09

(SPARE)

WELLSLOT#10 WELLSLOT#11 WELLSLOT#12

(SPARE)

SSJB-XXX (SPARE)

265-XB2020 (2T) B.O.S EL.+ 14920

265-XB2021 (2T) B.O.S EL.+ 14920

I

G N D N A L T A O B

H C A O R P P A

Y R A M R P

I

)

E R A P S

(

E B U T

J

” 2 1 :

D O

N 2 1 P H W M O R F

(1T) 265-XB2026 B.O.S EL.+ 13900

TO JACKET LEVEL

T.O.S. EL.+9700

LAYDOWN “D” 3000(L) x 2000(W)

T.O.P. EL.+11010

T.O.S. EL.+12800

UP

UP

TO PRODUCTION DECK

AFFF 135 L

XXX-FEXXXX (HOLD-1)

9 Kg

XXX-FEXXXX (HOLD-1)

265-XZ8313

NOTES:

  1. ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS

UNLESS STATED OTHERWISE.

  1. PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT,

SECONDARY ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.)

  1. THE MINIMUM HEADROOM HEIGHT SHALL BE PROVIDED IN

ALL PARTS, MEASURED VERTICALLY FROM DECK SURFACE OF LANDING OR PLATFORM.

  1. THIS LAYOUT SHALL BE USED ONLY FOR QUANTITY AND

LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENT AND DIRECTION OF ESCAPE ROUTES.

  1. AS PER TECHNICAL SAFETY BASIS OF DESIGN

(200-20-SH-DEC-00013) – FOR OUTDOOR AREAS, THE DEAD END SHALL NOT EXCEED 6 M OF TRAVEL DISTANCE.

  1. THE PORTABLE EXTINGUISHERS LOCATED OUTDOOR SHALL

BE PROVIDED WITH WEATHER-PROOF CABINET.

  1. WHEELED EXTINGUISHERS LOCATED OUTDOOR SHALL BE

PROVIDED WITH A UV-RESISTANT RED-VINYL COVER. 8. ARROWS SHOWN ON THE ESCAPE ROUTE INDICATE THE

PREFERRED DIRECTION OF EGRESS TOWARDS THE PRIMARY MUSTER AREA.

  1. LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING

EQUIPMENT AND DIRECTIONAL ARROWS INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION.

A

B

10.STAIRCASES SHOULD ALLOW TRANSPORTATION OF AN

INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.

C

  1. ALL FIRE & SAFETY EQUIPMENT SHALL BE LOCATED IN SUCH

A WAY THAT THEY ARE EASILY ACCESSIBLE.

12.BREATHING AIR MANIFOLD 6 PERSON IS PROVIDED, AS PER TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).

  1. ALL ESCAPE ROUTES SHALL BE MARKED WITH ESCAPE MARKER PAINTED ON THE FLOOR IN OIL RESISTANT PHOTOLUMINESCENT PAINT THAT IS VISIBLE, DURABLE AND ANTI-SLIP.

15379

3190

REFER DETAIL-1

REFER DETAIL-2

265-P8701B

(1T) 265-XB2022 B.O.S EL.+ 13660

(1T) 265-XB2023 B.O.S EL.+ 13660

265-P8701A

T.O.S. EL.+9500

LEGENDS:

LEGEND

AFFF 135 L

9 Kg

DESCRIPTIONS PRIMARY ESCAPE ROUTE 1.12m(WIDTH) X 2.286m(HEAD CLEARANCE) SECONDARY ESCAPE ROUTE 0.76m(WIDTH) X 2.286m(HEAD CLEARANCE) 135L AFFF FOAM WHEELED FIRE EXTINGUISHER

9 kg POTASSIUM BICARBONATE DRY CHEMICAL POWDER (BC) PORTABLE FIRE EXTINGUISHER

LIFEBUOY WITH LIFELINE

BAM 6

BREATHING AIR MANIFOLD CABINET WITH 6 NUMBERS OF HOSE UNIT (NOTE-12)

QTY

1

3

4

1

9 Kg

XXX-FEXXXX (HOLD-1)

TEMPSC DROP ZONE 7550(L) X 3190(W)

HOLDS:

  1. TAG NOS.

265-XB2024

(1T)

B.O.S EL.+ 13900

265-XZ8312

1M

0

1M

2M

3M

4M

5M

200-20-SH-DEC-00013

265-23-PI-PLP-00002

REFERENCE No.

TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT EQUIPMENT ARRANGEMENT PLAN CELLAR DECK FOR WHP13N

TITLE

REFERENCES

A

A1

No.

ISSUED FOR REVIEW

ISSUED FOR IDC

DESCRIPTION

DP

MTA

JB

JB

BPB

09/04/25

BPB

24/03/25

BY

CHKD

APVD

DATE

REVISIONS

PROJECT TITLE :

COMP3 - NFPS OFFSHORE RISER / WELLHEAD PLATFORM & INTRAFIELD PIPELINES PROJECT

100

0 0 2

100

0 0 2

400

400

Qatar Energy LNG

D

E

F

G

H

I

J

K

L

EQUIPMENT NO.

DESCRIPTION

SIZE (MM)

EQUIPMENT NO.

DESCRIPTION

SIZE (MM)

EQUIPMENT NO.

DESCRIPTION

SIZE (MM)

EQUIPMENT NO.

DESCRIPTION

SIZE (MM)

EQUIPMENT LIST

EQUIPMENT LIST

EQUIPMENT LIST

EQUIPMENT LIST

CELLAR DECK (T.O.S EL.+11000)

TYPICAL DETAIL-1

TYPICAL DETAIL-2

N.T.S

N.T.S

265-H8701 265-P8701A

265-P8701B 265-T8701

265-V8701 265-Y8701

265-P8702A

265-P8702B

1

FLARE KO/CLOSED DRAIN DRUM HEATER LIQUID RETURN BOOSTER PUMP LIQUID RETURN BOOSTER PUMP

OPEN DRAIN TANK

OPEN FLARE KO DRUM/CLOSED DRAIN DRUM

SEWAGE MACERATOR

LIQUID RETURN PUMP LIQUID RETURN PUMP

2

PART OF KO DRUM

2200 (L) X 1000 (W) X 1105 (H)

2200 (L) X 1000 (W) X 1105 (H) 3800 (L) X 2400 (W) X 1500 (H) 1850 (ID) X 4100 (T/T)

494 (L) X 226 (W) X 333 (H)

3500 (L) X 1845 (W) X 1840 (H) 3500 (L) X 1845 (W) X 1840 (H) 4

3

265-P8703 265-P8704

265-P9301A 265-P9301B 265-S9301 265-P9401

SSJB-265601 SSJB-XXX(SPARE)

OPEN DRAIN WATER PUMP OPEN DRAIN OIL PUMP DIESEL TRANSFER PUMP

DIESEL TRANSFER PUMP

DIESEL FILTER COALESTER

WASHDOWN WATER PUMP J-TUBE SPLITTER BOX

J-TUBE SPLITTER BOX

2674(L) X 618 (W) X 764 (H)

1219(L) X 483(W) X 480(H)

1848(L) X 610(W) X 502(H) 1848(L) X 610(W) X 502(H) 406(ID) X 2301(H)

600(L) X 600(W) X 991(H) 1350(L) X 450(W) X 2200(H)

1350(L) X 450(W) X 2200(H)

265-XB2020

265-XB2021 265-XB2022

265-XB2023 265-XB2024

265-XB2025

265-XB2026 265-XB2027

MONORAIL 2T MONORAIL 2T MONORAIL 1T

MONORAIL 1T MONORAIL 1T

MONORAIL 1T

MONORAIL 1T MONORAIL 1T

265-XB2028 265-US-06

MONORAIL 1T UTILITY STATION

Qatar Energy LNG

THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.

CONSULTANT / CONTRACTOR :

Saipem S.p.A.

CONTRACTOR DRAWING No. :

033764-M-D00-11-SPM-LP-D-00045-0001

TITLE :

FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - CELLAR DECK - WHP13N

SCALE :

1:100

PROJECT No. :

LTC/C/NFP/5129/20

PROJECT

033764

DRAWING No.

SHT

SIZE REVISION

265-83-SH-PLN-00001

0001

A1

A

5

6

7

10

11

12

13

14

15

16

A

B

C

D

E

F

G

H

I

J

K

L

Project: Q-32705 - Saipem COMP3 Folder: RFQ Files


Loading authentication...

Graph View

Backlinks

  • 00 Index

Created with Infinity Constructor © 2025

  • Elynox | Go Further