Classification: Internal
1
PLATFORM NORTH
30°
A
N
B
E H U T R R T O N
E H U T R R T O N
PREVAILING WIND
C
D
E
F
G
N. 100000
265-XZ8365
XXX-FEXXXX (HOLD-1)
1
BC 56.7 kg
H
265-XZ8315
9 Kg
XXX-FEXXXX (HOLD-1)
I
J
K
SPACE FOR MEG FILLING TOTE TANK-A
SPACE FOR MEG FILLING TOTE TANK-B
SPACE FOR TEMPORARY COMPRESSOR
BOOM TIP MAINTENANCE PLATFORM 3000(L) x 3000(W)
DROP ZONE FROM CRANE BOOM TIP MAINTENANCE PLATFORM 1500(L) x 1000(W)
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
0 0 0 0 0 1
.
E
B
0 0 0 5 1 1
.
E
(HOLD-1) XXX-FEXXXX
9 Kg
MIN. CRANE RADIUS 6.7m (22.5 MT)
15000
15000
0 0 7 6 R
C
0 0 0 0 3 1
.
E
265-XZ8301
(HOLD-1) XXX-XZXXXX
(HOLD-1) XXX-FEXXXX
BAM 12
9 Kg
20222
T.O.S. EL. +25900
NO GO ZONE LIMITS
EMERGENCY LADDER FROM HELIDECK
NOTES:
- ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS
UNLESS STATED OTHERWISE.
-
BREATHING AIR MANIFOLD 6 PERSON IS PROVIDED, AS PER TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).
-
BREATHING AIR MANIFOLD 12 PERSON IS PROVIDED, AS PER TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).
-
THIS LAYOUT SHALL BE USED ONLY FOR QUANTITY AND
LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENT AND DIRECTION OF ESCAPE ROUTES.
A
- PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT,
SECONDARY ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.)
-
THE MINIMUM HEADROOM HEIGHT SHALL BE PROVIDED IN ALL PARTS, MEASURED VERTICALLY FROM DECK SURFACE OF LANDING OR PLATFORM.
-
THE PORTABLE EXTINGUISHERS LOCATED OUTDOOR SHALL
B
BE PROVIDED WITH WEATHER-PROOF CABINET.
- WHEELED EXTINGUISHERS LOCATED OUTDOOR SHALL BE
PROVIDED WITH A UV-RESISTANT RED-VINYL COVER. 9. ARROWS SHOWN ON THE ESCAPE ROUTE INDICATE THE
PREFERRED DIRECTION OF EGRESS TOWARDS THE PRIMARY MUSTER AREA.
10.LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING
EQUIPMENT AND DIRECTIONAL ARROWS INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION.
11.STAIRCASES SHOULD ALLOW TRANSPORTATION OF AN
C
INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.
- ALL FIRE & SAFETY EQUIPMENT SHALL BE LOCATED IN SUCH
A WAY THAT THEY ARE EASILY ACCESSIBLE.
-
ALL ESCAPE ROUTES SHALL BE MARKED WITH ESCAPE MARKER PAINTED ON THE FLOOR IN OIL RESISTANT PHOTOLUMINESCENT PAINT THAT IS VISIBLE, DURABLE AND ANTI-SLIP.
-
AS PER TECHNICAL SAFETY BASIS OF DESIGN
(200-20-SH-DEC-00013) – FOR OUTDOOR AREAS, THE DEAD END SHALL NOT EXCEED 6 M OF TRAVEL DISTANCE. 15.INTERNATIONAL SHIP/SHORE CONNECTION (4 NO’S x 2.5” MALE BS 336 INSTANTANEOUS COUPLING WITH 6” PIPING CONNECTION) SHALL BE PROVIDED FOR FLEXIBLE HOSE CONNECTION FROM JACK-UP RIG (JUR) FOR FIRE WATER SUPPLY TO DRY DELUGE SYSTEM PROVIDED FOR WELLHEAD AREA.
D
QTY
E
LEGENDS:
LEGEND
9 Kg
BC 56.7 kg
BAM 6
BAM 12
DESCRIPTIONS PRIMARY ESCAPE ROUTE 1.12m(WIDTH) X 2.286m(HEAD CLEARANCE) SECONDARY ESCAPE ROUTE 0.76m(WIDTH) X 2.286m(HEAD CLEARANCE) 135L AFFF FOAM WHEELED FIRE EXTINGUISHER
9 kg POTASSIUM BICARBONATE DRY CHEMICAL POWDER (BC) PORTABLE FIRE EXTINGUISHER
56.7kg DRY CHEMICAL POWDER (BC) WHEELED FIRE EXTINGUISHER
LIFEBUOY WITH LIFELINE
BREATHING AIR MANIFOLD CABINET WITH 6 NUMBERS OF HOSE UNIT (NOTE 2)
BREATHING AIR MANIFOLD CABINET WITH 12 NUMBERS OF HOSE UNIT (NOTE 3)
DECK INTEGRATED FIRE FIGHTING SYSTEM
INTERNATIONAL SHIP/SHORE CONNECTION (NOTE-15)
1
6
1
4
1
2
1
1
EDGE OF HELIDECK
265-XZ8317
BAM 12
XXX-XZXXXX (HOLD-1)
SECONDARY BOAT LANDING APPROACH
265-XZ8316
N. 122250
3
265-XZ8314
(HOLD-1) XXX-FEXXXX
0 5 2 8
DROP ZONE TO LAYDOWN ‘C’ PRODUCTION DECK 6000(L) x 2500(W) 10T
DN
TO PRODUCTION DECK
LAYDOWN’B’ 11000(L) x 2500(W) 20T
UP UP
TO HELI TO HELI DECK DECK
EMERGENCY DIESEL GENERATOR (TEMPORARY)
RESERVE FOR FUTURE AREA 6800(L) X 4150(W)
265-XZ8301
9 Kg
(HOLD-1) XXX-FEXXXX
2
N. 114000
DRILLING RIG FOOT PRINT
WELLSLOT#1
WELLSLOT#2
WELLSLOT#3
REMOVABLE HATCH (TYP.)
265-XP96100142D/E
WELLSLOT#4
WELLSLOT#5
WELLSLOT#6
T.O.S. EL. +25900
265-XP96100142A/B/C
(SPARE)
265-US-02
NO GO ZONE LIMITS
265-T9402
0 0 0 4 1
(SPARE)
(SPARE)
WELLSLOT#7
WELLSLOT#8
WELLSLOT#9
RESERVE FOR FUTURE AREA
18350(L) X5800(W)
WELLSLOT#10
WELLSLOT#11
WELLSLOT#12
(SPARE)
(SPARE)
TEMPORARY CRANE BOOM REST
1 0
S U
5 6 2
265-XP9601D/E/F
265-XP9601A/B/C
A 1 0 U H A 1 0 2 4 H Y
5 6 2
UP
TO HELI DECK
B 1 0 U H A 1 0 2 4 H Y
5 6 2
K C E D F O E G D E
REFER DETAIL-2
265-YH4201ACCU01A
265-YH4201ACCU01B
XXX-FEXXXX (HOLD-1)
9 Kg
HOLDS:
- TAG NOS.
CRANE BOOM REST
REFER DETAIL-1
ANTENNA
RESERVE FOR FUTURE PLATFORM 5300(L) X2700(W)
DROP ZONE TO LAYDOWN ‘A’ AT PRODUCTION DECK 3800(L) x 3000(W)
UP
DROP ZONE TO LAYDOWN ‘D’ ATCELLAR DECK 3000(L) x 2100(W) 2T
TOS EL.23960
DN
DROP ZONE TO LAYDOWN ‘F’ 3000(L) x 2000(W) 5T
28.5m CRANE NO-GO ZONE RADIUS
1 6 5 D E G
DN
TO PRODUCTION DECK
LAYDOWN AREA FOR LER LEVEL-2 1500(L) x 1500(W)
XXX-XZXXXX (HOLD-1)
BAM 6
XXX-FEXXXX (HOLD-1)
9 Kg
DRILL DECK (T.O.S. EL. +25900)
EDGE OF DECK
MAX. CRANE RADIUS 35m (22.5MT)
200-20-SH-DEC-00013
265-23-PI-PLP-00005
REFERENCE No.
TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT EQUIPMENT ARRANGEMENT PLAN DRILL DECK FOR WHP13N
TITLE
REFERENCES
A
A1
No.
ISSUED FOR REVIEW
ISSUED FOR IDC
DESCRIPTION
DP
MTA
JB
JB
BPB
09/04/25
BPB
24/03/25
BY
CHKD
APVD
DATE
REVISIONS
PROJECT TITLE :
COMP3 - NFPS OFFSHORE RISER / WELLHEAD PLATFORM & INTRAFIELD PIPELINES PROJECT
Qatar Energy LNG
Qatar Energy LNG
THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.
CONSULTANT / CONTRACTOR :
Saipem S.p.A.
CONTRACTOR DRAWING No. :
033764-M-D00-15-SPM-LP-D-00042-0001
100
0 0 2
100
0 0 2
400
400
TITLE :
FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - DRILL DECK - WHP13N
SCALE :
1:100
PROJECT No. :
LTC/C/NFP/5129/20
PROJECT
033764
DRAWING No.
SHT
SIZE REVISION
265-83-SH-PLN-00002
0001
A1
A
1M
0
1M
2M
3M
4M
5M
EQUIPMENT LIST
EQUIPMENT LIST
EQUIPMENT NO.
DESCRIPTION
SIZE (MM)
EQUIPMENT NO.
DESCRIPTION
SIZE (MM)
265-Y9101
EMERGENCY DIESEL ENGINE GENERATOR 12000(L) X 4200(W) X 6000(H) (TEMPORARY)
265-YH4201ACCU01A 265-YH4201ACCU01B
AIR COOLED CONDENSING UNIT (DUTY) AIR COOLED CONDENSING UNIT (STANDBY)
3000(L) X 2000(W) X 2400(H) 3000(L) X 2000(W) X 2400(H)
265-XP96100142 A/E
TEMPORARY NITROGEN CYLINDER RACK 2100(L) x 1940(W) X 1940(H)
265-XP9601 A/B
NITROGEN CYLINDER RACK
265-XZ8301
L
265-YH4201AHU01A
DECK INTEGRATED FIRE FIGHTING SYSTEM
(DIFFS) FOR HELIDECK AIR HANDLING UNIT (DUTY)
9000(L) X 2875(W) X 2699(H)
265-XP9601 C/D
NITROGEN CYLINDER RACK
265-XP9601 E/F
NITROGEN CYLINDER RACK
4500(L) X 2000(W) X 2400(H)
265-XC9301
PEDESTAL CRANE
265-YH4201AHU01B
AIR HANDLING UNIT (STANDBY)
4500(L) X 2000(W) X 2400(H)
265-US-01
265-T9402
GRP-WATER TANK
1000(L) X 1000(W) X 1160(H)
265-US-01
UTILITY STATION
UTILITY STATION
1507(L) x 1452(W) X 2200(H)
1507(L) x 1452(W) X 2200(H)
1507(L) x 1452(W) X 2200(H)
4456(L) X 6927(W) X 16535(H)
1
2
3
4
5
6
7
10
11
12
13
14
15
16
F
G
H
I
J
K
L
Project: Q-32705 - Saipem COMP3 Folder: RFQ Files