Infinity

Not logged in
Home

❯

Reference Examples

❯

Q 32705 Saipem COMP3

❯

RFQ Files

❯

265 83 SH PLN 00002_A

Classification: Internal

1

PLATFORM NORTH

30°

A

N

B

E H U T R R T O N

E H U T R R T O N

PREVAILING WIND

C

D

E

F

G

N. 100000

265-XZ8365

XXX-FEXXXX (HOLD-1)

1

BC 56.7 kg

H

265-XZ8315

9 Kg

XXX-FEXXXX (HOLD-1)

I

J

K

SPACE FOR MEG FILLING TOTE TANK-A

SPACE FOR MEG FILLING TOTE TANK-B

SPACE FOR TEMPORARY COMPRESSOR

BOOM TIP MAINTENANCE PLATFORM 3000(L) x 3000(W)

DROP ZONE FROM CRANE BOOM TIP MAINTENANCE PLATFORM 1500(L) x 1000(W)

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

A

0 0 0 0 0 1

.

E

B

0 0 0 5 1 1

.

E

(HOLD-1) XXX-FEXXXX

9 Kg

MIN. CRANE RADIUS 6.7m (22.5 MT)

15000

15000

0 0 7 6 R

C

0 0 0 0 3 1

.

E

265-XZ8301

(HOLD-1) XXX-XZXXXX

(HOLD-1) XXX-FEXXXX

BAM 12

9 Kg

20222

T.O.S. EL. +25900

NO GO ZONE LIMITS

EMERGENCY LADDER FROM HELIDECK

NOTES:

  1. ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS

UNLESS STATED OTHERWISE.

  1. BREATHING AIR MANIFOLD 6 PERSON IS PROVIDED, AS PER TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).

  2. BREATHING AIR MANIFOLD 12 PERSON IS PROVIDED, AS PER TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).

  3. THIS LAYOUT SHALL BE USED ONLY FOR QUANTITY AND

LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENT AND DIRECTION OF ESCAPE ROUTES.

A

  1. PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT,

SECONDARY ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.)

  1. THE MINIMUM HEADROOM HEIGHT SHALL BE PROVIDED IN ALL PARTS, MEASURED VERTICALLY FROM DECK SURFACE OF LANDING OR PLATFORM.

  2. THE PORTABLE EXTINGUISHERS LOCATED OUTDOOR SHALL

B

BE PROVIDED WITH WEATHER-PROOF CABINET.

  1. WHEELED EXTINGUISHERS LOCATED OUTDOOR SHALL BE

PROVIDED WITH A UV-RESISTANT RED-VINYL COVER. 9. ARROWS SHOWN ON THE ESCAPE ROUTE INDICATE THE

PREFERRED DIRECTION OF EGRESS TOWARDS THE PRIMARY MUSTER AREA.

10.LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING

EQUIPMENT AND DIRECTIONAL ARROWS INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION.

11.STAIRCASES SHOULD ALLOW TRANSPORTATION OF AN

C

INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.

  1. ALL FIRE & SAFETY EQUIPMENT SHALL BE LOCATED IN SUCH

A WAY THAT THEY ARE EASILY ACCESSIBLE.

  1. ALL ESCAPE ROUTES SHALL BE MARKED WITH ESCAPE MARKER PAINTED ON THE FLOOR IN OIL RESISTANT PHOTOLUMINESCENT PAINT THAT IS VISIBLE, DURABLE AND ANTI-SLIP.

  2. AS PER TECHNICAL SAFETY BASIS OF DESIGN

(200-20-SH-DEC-00013) – FOR OUTDOOR AREAS, THE DEAD END SHALL NOT EXCEED 6 M OF TRAVEL DISTANCE. 15.INTERNATIONAL SHIP/SHORE CONNECTION (4 NO’S x 2.5” MALE BS 336 INSTANTANEOUS COUPLING WITH 6” PIPING CONNECTION) SHALL BE PROVIDED FOR FLEXIBLE HOSE CONNECTION FROM JACK-UP RIG (JUR) FOR FIRE WATER SUPPLY TO DRY DELUGE SYSTEM PROVIDED FOR WELLHEAD AREA.

D

QTY

E

LEGENDS:

LEGEND

9 Kg

BC 56.7 kg

BAM 6

BAM 12

DESCRIPTIONS PRIMARY ESCAPE ROUTE 1.12m(WIDTH) X 2.286m(HEAD CLEARANCE) SECONDARY ESCAPE ROUTE 0.76m(WIDTH) X 2.286m(HEAD CLEARANCE) 135L AFFF FOAM WHEELED FIRE EXTINGUISHER

9 kg POTASSIUM BICARBONATE DRY CHEMICAL POWDER (BC) PORTABLE FIRE EXTINGUISHER

56.7kg DRY CHEMICAL POWDER (BC) WHEELED FIRE EXTINGUISHER

LIFEBUOY WITH LIFELINE

BREATHING AIR MANIFOLD CABINET WITH 6 NUMBERS OF HOSE UNIT (NOTE 2)

BREATHING AIR MANIFOLD CABINET WITH 12 NUMBERS OF HOSE UNIT (NOTE 3)

DECK INTEGRATED FIRE FIGHTING SYSTEM

INTERNATIONAL SHIP/SHORE CONNECTION (NOTE-15)

1

6

1

4

1

2

1

1

EDGE OF HELIDECK

265-XZ8317

BAM 12

XXX-XZXXXX (HOLD-1)

SECONDARY BOAT LANDING APPROACH

265-XZ8316

N. 122250

3

265-XZ8314

(HOLD-1) XXX-FEXXXX

0 5 2 8

DROP ZONE TO LAYDOWN ‘C’ PRODUCTION DECK 6000(L) x 2500(W) 10T

DN

TO PRODUCTION DECK

LAYDOWN’B’ 11000(L) x 2500(W) 20T

UP UP

TO HELI TO HELI DECK DECK

EMERGENCY DIESEL GENERATOR (TEMPORARY)

RESERVE FOR FUTURE AREA 6800(L) X 4150(W)

265-XZ8301

9 Kg

(HOLD-1) XXX-FEXXXX

2

N. 114000

DRILLING RIG FOOT PRINT

WELLSLOT#1

WELLSLOT#2

WELLSLOT#3

REMOVABLE HATCH (TYP.)

265-XP96100142D/E

WELLSLOT#4

WELLSLOT#5

WELLSLOT#6

T.O.S. EL. +25900

265-XP96100142A/B/C

(SPARE)

265-US-02

NO GO ZONE LIMITS

265-T9402

0 0 0 4 1

(SPARE)

(SPARE)

WELLSLOT#7

WELLSLOT#8

WELLSLOT#9

RESERVE FOR FUTURE AREA

18350(L) X5800(W)

WELLSLOT#10

WELLSLOT#11

WELLSLOT#12

(SPARE)

(SPARE)

TEMPORARY CRANE BOOM REST

1 0

S U

5 6 2

265-XP9601D/E/F

265-XP9601A/B/C

A 1 0 U H A 1 0 2 4 H Y

5 6 2

UP

TO HELI DECK

B 1 0 U H A 1 0 2 4 H Y

5 6 2

K C E D F O E G D E

REFER DETAIL-2

265-YH4201ACCU01A

265-YH4201ACCU01B

XXX-FEXXXX (HOLD-1)

9 Kg

HOLDS:

  1. TAG NOS.

CRANE BOOM REST

REFER DETAIL-1

ANTENNA

RESERVE FOR FUTURE PLATFORM 5300(L) X2700(W)

DROP ZONE TO LAYDOWN ‘A’ AT PRODUCTION DECK 3800(L) x 3000(W)

UP

DROP ZONE TO LAYDOWN ‘D’ ATCELLAR DECK 3000(L) x 2100(W) 2T

TOS EL.23960

DN

DROP ZONE TO LAYDOWN ‘F’ 3000(L) x 2000(W) 5T

28.5m CRANE NO-GO ZONE RADIUS

1 6 5 D E G

DN

TO PRODUCTION DECK

LAYDOWN AREA FOR LER LEVEL-2 1500(L) x 1500(W)

XXX-XZXXXX (HOLD-1)

BAM 6

XXX-FEXXXX (HOLD-1)

9 Kg

DRILL DECK (T.O.S. EL. +25900)

EDGE OF DECK

MAX. CRANE RADIUS 35m (22.5MT)

200-20-SH-DEC-00013

265-23-PI-PLP-00005

REFERENCE No.

TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT EQUIPMENT ARRANGEMENT PLAN DRILL DECK FOR WHP13N

TITLE

REFERENCES

A

A1

No.

ISSUED FOR REVIEW

ISSUED FOR IDC

DESCRIPTION

DP

MTA

JB

JB

BPB

09/04/25

BPB

24/03/25

BY

CHKD

APVD

DATE

REVISIONS

PROJECT TITLE :

COMP3 - NFPS OFFSHORE RISER / WELLHEAD PLATFORM & INTRAFIELD PIPELINES PROJECT

Qatar Energy LNG

Qatar Energy LNG

THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.

CONSULTANT / CONTRACTOR :

Saipem S.p.A.

CONTRACTOR DRAWING No. :

033764-M-D00-15-SPM-LP-D-00042-0001

100

0 0 2

100

0 0 2

400

400

TITLE :

FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - DRILL DECK - WHP13N

SCALE :

1:100

PROJECT No. :

LTC/C/NFP/5129/20

PROJECT

033764

DRAWING No.

SHT

SIZE REVISION

265-83-SH-PLN-00002

0001

A1

A

1M

0

1M

2M

3M

4M

5M

EQUIPMENT LIST

EQUIPMENT LIST

EQUIPMENT NO.

DESCRIPTION

SIZE (MM)

EQUIPMENT NO.

DESCRIPTION

SIZE (MM)

265-Y9101

EMERGENCY DIESEL ENGINE GENERATOR 12000(L) X 4200(W) X 6000(H) (TEMPORARY)

265-YH4201ACCU01A 265-YH4201ACCU01B

AIR COOLED CONDENSING UNIT (DUTY) AIR COOLED CONDENSING UNIT (STANDBY)

3000(L) X 2000(W) X 2400(H) 3000(L) X 2000(W) X 2400(H)

265-XP96100142 A/E

TEMPORARY NITROGEN CYLINDER RACK 2100(L) x 1940(W) X 1940(H)

265-XP9601 A/B

NITROGEN CYLINDER RACK

265-XZ8301

L

265-YH4201AHU01A

DECK INTEGRATED FIRE FIGHTING SYSTEM

(DIFFS) FOR HELIDECK AIR HANDLING UNIT (DUTY)

9000(L) X 2875(W) X 2699(H)

265-XP9601 C/D

NITROGEN CYLINDER RACK

265-XP9601 E/F

NITROGEN CYLINDER RACK

4500(L) X 2000(W) X 2400(H)

265-XC9301

PEDESTAL CRANE

265-YH4201AHU01B

AIR HANDLING UNIT (STANDBY)

4500(L) X 2000(W) X 2400(H)

265-US-01

265-T9402

GRP-WATER TANK

1000(L) X 1000(W) X 1160(H)

265-US-01

UTILITY STATION

UTILITY STATION

1507(L) x 1452(W) X 2200(H)

1507(L) x 1452(W) X 2200(H)

1507(L) x 1452(W) X 2200(H)

4456(L) X 6927(W) X 16535(H)

1

2

3

4

5

6

7

10

11

12

13

14

15

16

F

G

H

I

J

K

L

Project: Q-32705 - Saipem COMP3 Folder: RFQ Files


Loading authentication...

Graph View

Backlinks

  • 00 Index

Created with Infinity Constructor © 2025