Classification: Internal
1
2
3
4
5
6
7
8
9
11
12
13
14
15
16
A
B
C
D
E
F
G
H
I
J
K
L
B
2
7500
B
3550
HVAC DUCTING (300x200) TO FLOOR VOID
9150
61
12
13
3
1
DH
16
17
5
6
7
8
132
2
152
151
150
14
141
140
211
82 101
EXIT
95
94
F B
92
ELECTRICAL & INSTRUMENT ROOM
56
131
130
R O F E C A P S D E T A C O L L A
L O O T F O E G A R O T S
R O F E C A P S D E T A C O L L A
Y A R T E L B A C L A C R T C E L E
I
153
154
155
156
157
158
159
160
200
I
T X E
92
100
81
112
ESK
161
162
15
134
133
62
102
ALLOCATED SPACE FOR INST. / TELE. CABLE TRAY
A
L L A W T S A L B E R F
I
/
A
0 0 0 4 1
0 0 3 4
CO2 4.5 kg
265-FEXXXX (HOLD-1)
FB
265-XZ8343
1
265-XZ8356
182
72
209
163
TEMPORARY REFUGE AREA (0.6 SQM x 30 POB )
71
75
80
79
73
93
90
94
57
92
EXIT
B
BAM 10
265-XZXXXX (HOLD-1)
BA
265-XZ8306
BAM 10
265-XZXXXX (HOLD-1)
AIR LOCK ROOM
EXIT
103
0 0 8 1
7 4 3
FLOOR PLAN VIEW EL.+17253 T.O.F (FIRST FLOOR)
347
2700
350
PRODUCTION DECK EL. +16350 T.O.S
10
QTY
3
3
1
2
1
2
1
1
LEGEND
DESCRIPTIONS
CO2 4.5 kg
BAM 10
BA
4.5kg CO2 PORTABLE FIRE EXTINGUISHER
BREATHING AIR MANIFOLD CABINET WITH 10 NUMBERS OF HOSE UNIT (NOTE-2)
BREATHING APPARATUS ESCAPE SET (15 MINUTES AND 3L CYLINDER)
STRETCHER
FB
FIRE BLANKET
FIRST AID KIT
ESK
ELECTRICAL SAFETY KIT
OXYGEN
FULL CYLINDER
OXYGEN CYLINDER WITH THE MASK
CO2 4.5 kg
265-FEXXXX (HOLD-1)
ESK 265-XZ8348
BAM 10
265-XZXXXX (HOLD-1)
X2
265-XZ8352 265-XZ8353
OXYGEN
FULL CYLINDER
265-XZ8362
265-XZ8355
265-FEXXXX (HOLD-1)
CO2 4.5 kg
EQUIPMENT LIST FOR ELECTRICAL & INSTRUMENT ROOM (LER 1ST FLOOR)
SI.NO.
TAG NUMBER
DESCRIPTION
DIMENSIONS (MM)
LENGTH
WIDTH
HEIGHT
WEIGHT (KG)
TYPE OF MOUNTING
ELECTRICAL EQUIPMENT LIST
1
2
3
5
6
7
8
12
13
14
15
16
17
56
61
62
150
151
152
153
154
155
156
157
158
159
160
161
162
211
140
141
81
82
92
94
95
100
101
102
112
130
131
132
133
134
265-SB-91601
MEDIUM VOLTAGE SWITCHBOARD (11KV)
265-MCC-91301
LV MOTOR CONTROL CENTER
265-TR-91301
TRANSFORMER
265-LP-91301
LIGHTING & SMALL POWER DISTRIBUTION PANEL
265-PDB-91301
AC POWER DISTRIBUTION BOARD
265-PDB-91303
AC POWER DISTRIBUTION BOARD
265-PDB-91304
AC POWER DISTRIBUTION BOARD
CP-260101
SUBSEA CABLE MONITORING
PD MONITORING PANEL
IMCS PANEL
KEY ONLINE DIAGRAM FRAME
265-CBT-4101-01
LIFTING TRUCK FOR ACB
265-CBT-4101-02
LIFTING TRUCK FOR VCB
PADLOCK KEY BOX
1670
8850
1800
1000
800
800
800
600
300
800
1000
1000
1000
250
HVAC EQUIPMENT LIST
265-ACP-42301
HVAC CONTROL PANEL
1200
600
HVAC PURGE PANEL FOR ELECTRICAL ROOM - LER 1ST FLOOR
INSTRUMENT EQUIPMENT LIST
IRP
ICSS PDB
FUTURE CABINET-1
ESD SYSTEM CABINET-1
ESD MARSHALLING CABINET-1
ESD SYSTEM CABINET-2
ESD MARSHALLING CABINET-2
F&G SYSTEM CABINET-1
F&G MARSHALLING CABINET-1
F&G SYSTEM CABINET-2
F&G MARSHALLING CABINET-2
HSSD PANEL-1
HSSD PANEL-2
800
800
800
800
800
800
800
800
800
800
800
600
600
TELECOM EQUIPMENT LIST
ACS ENCLOSURE
616
MECHANICAL EQUIPMENT LIST
MEG PUMP VFD A
265-TCP-8701
THYRISTOR CONTROL PANEL
800
1000
LOSPE EQUIPMENT LIST
NOVEC LOCAL STATUS PANEL 1
NOVEC LOCAL STATUS PANEL 2
6.8KG CO2 EXTINGUISHER (2 NO.)
FIRST AID KIT
FIRE BLANKET
NOVEC INDOOR PUSH BUTTON & LAMP PANEL
NOVEC INDOOR PUSH BUTTON & LAMP PANEL
NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL
ELECTRICAL SAFETY KIT
300
300
178 DIA
448
300
450
450
450
1000
ARCHITECTURAL EQUIPMENT LIST
FILE CABINET-1
FILE CABINET-2
FILE CABINET-3
TABLE WITH CHAIRS
REFRIGERATOR
600
600
800
650
1765
1600
1300
500
500
500
500
600
200
800
50
750
750
100
800
500
800
800
800
800
800
800
800
800
800
800
800
300
300
300
800
400
150
150
213
500
300
300
300
400
450
450
500
600
2800
2300
2200
1200
1400
1400
1400
2000
500
2200
700
1800
1158
350
2100
1000
2100
2100
2100
2100
2100
2100
2100
2100
2100
2100
2100
600
600
2332
FLOOR MOUNTED
13560
FLOOR MOUNTED
2050
FLOOR MOUNTED
300
125
125
125
450
150
300
10
110
90
10
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
FLOOR MOUNTED
WALL MOUNTED
FLOOR MOUNTED
WALL MOUNTED
PORTABLE
PORTABLE
WALL MOUNTED
1000
FLOOR MOUNTED
200
WALL MOUNTED
450
450
450
450
450
450
450
450
450
450
150
150
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
WALL MOUNTED
616
80
WALL MOUNTED
2100
2200
300
300
1225
425
1200
450
450
450
350
450
FLOOR MOUNTED
FLOOR MOUNTED
15
15
23
15
10
40
40
40
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
1800
145
FLOOR MOUNTED
1880
1880
1200
1200
100
100
100
150
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
EQUIPMENT LIST FOR TEMPORARY REFUGE (LER 1ST FLOOR)
SI.NO.
TAG NUMBER
DESCRIPTION
DIMENSIONS (MM)
LENGTH
WIDTH
HEIGHT
WEIGHT (KG)
TYPE OF MOUNTING
163
182
209
71
72
73
75
79
80
90
92
93
94
103
57
INSTRUMENT EQUIPMENT LIST
DCS CONSOLE (OWS )
MULTI -GAS DETECTOR
1000
455
800
450
770
640
200
FLOOR MOUNTED
FLOOR MOUNTED
TELECOM EQUIPMENT LIST
TELECOM CONSOLE - 2
800
600
1690
150
FLOOR MOUNTED
LOSPE EQUIPMENT LIST
BREATHING AIR MANIFOLD A
BREATHING AIR MANIFOLD B
BREATHING AIR MANIFOLD C
ESCAPE BREATHING APPARATUS CABINET
NOVEC MAIN JB
NOVEC CONTROL PANEL
OXYGEN CYLINDER WITH MASK
6.8KG CO2 EXTINGUISHER
STRETCHER 2 NO’S
FIRST AID KIT
NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL
1500
1500
1500
750
800
600
300
178 DIA
300
448
450
GENERAL EQUIPMENT LIST
610
610
610
600
450
450
300
500
213
300
960
960
960
857
1500
1200
1000
1225
1200
425
450
150
150
150
224
120
120
20
23
50
15
40
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
PORTABLE
NOTES: 1.
ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS UNLESS STATED OTHERWISE.
BREATHING AIR MANIFOLD 30 PERSON IS PROVIDED, AS PER TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).
A
THIS LAYOUT SHALL BE USED ONLY FOR QUANTITY AND LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENT AND DIRECTION OF ESCAPE ROUTES.
PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT, SECONDARY ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.)
NOVEC 1230 (FK-5-1-12) CLEAN AGENT SYSTEM PROTECTION SHALL BE PROVIDED FOR ELECTRICAL & INSTRUMENT ROOM AND UPS, INSTRUMENT AND TELECOM ROOM IN THE LER.
B
LOCATION OF FIREFIGHTING, SAFETY & LIFESAVING EQUIPMENT INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION.
ALL FIRE & SAFETY EQUIPMENT SHALL BE LOCATED IN SUCH A WAY THAT THEY ARE EASILY ACCESSIBLE.
OXYGEN CYLINDER WITH FACE MASK FOR CPR PURPOSE SHALL BE PROVIDED INSIDE BUILDING (IN TEMPORARY REFUGE).
FOR TEMPORARY REFUGE, AN OVERALL FREE FLOOR SPACE OF 18 M² (0.6 M2 /PERSON x POB (30 NOS.)) FOR PERSONNEL MUSTERING SHALL BE MAINTAINED IN THE TR.
- AIR LOCK ROOM SHOULD ALLOW SAFE MANEUVERING OF AN
INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.
HOLDS: 1.
TAG NOS.
KEY PLAN
0 5 7 3
0 0 0 2 1
0 0 5 5
1225
HOLD-1
0 0 0 4 1
6500
0 0 5 2
4000
4000
0 0 2 2
2225
16000
17000
6210
FUTRE DECK EXTENSION
16 Mx 3.75 M
14.5, x 2M
MIN. CRANE RADIUS 6.7M
2200
0 0 5 3
8 1 7 5
2000
2000
R O T A L U M U C C A
X X X
5 6 2
I
D K S
0 0 3 3
HPU PLC PANEL
800
0 0 8
265-XXX HOLD-1
4000
0 0 0 2
0 0 0 2 1
0 7 5 1
0 0 0 8
0 5 6 7
BOS.EL.20850 MONORAIL CAP. 2 T
2800mmx2300mm LAYDOWN AREA CAP. 2T
5 3 1 5 1
HOLD-2
4860
THIS DRAWING
200-20-SH-DEC-00013
265-91-EL-PLN-00001
REFERENCE No.
TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT ELECTRICAL EQUIPMENT LAYOUT LOCAL EQUIPMENT ROOM (LER) FOR WHP13N
TITLE
REFERENCES
A
A1
NO.
ISSUED FOR REVIEW
ISSUED FOR IDC
DESCRIPTION
DP
MTA
JB
JB
BPB
09/04/25
BPB
24/03/25
BY
CHKD
APVD
DATE
REVISIONS
C
D
E
F
G
H
I
J
K
L
WALL MOUNTED
PROJECT TITLE :
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
NFPS Offshore Riser Platforms & Intrafield Pipelines Project - COMP3
Qatar Energy LNG
PORTABLE HANDLAMP
300
200
350
3
WALL MOUNTED
Qatar Energy LNG
THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.
CONSULTANT / CONTRACTOR :
Saipem S.p.A.
CONTRACTOR DRAWING NO:
033764-M-D00-18-SPM-LP-D-00046-0001
TITLE :
FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - LOCAL EQUIPMENT ROOM - WHP13N
SCALE :
1:50
PROJECT NO. :
LTC/C/NFP/5129/20
PROJECT
033764
DRAWING NO.
SHT
SIZE REVISION
265-83-SH-PLN-00004
0001
A1
A
1
2
3
4
5
6
7
10
11
12
13
14
15
16
Classification: Internal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
2
A
1
CO2 4.5 kg
265-FEXXXX (HOLD-1)
A
B
C
D
E
F
G
H
I
J
K
L
B
1200
I
D O V R O O L F O T
) 0 0 2 x 0 0 3 (
I
G N T C U D C A V H
40
39
35
37
36
L L A W T S A L B E R F
/
I
0 0 0 4 1
Y A R T E L B A C L A C R T C E L E
I
R O F E C A P S D E T A C O L L A
(HOLD-1) 265-FEXXXX
CO2 4.5 kg
B 9900
9200
EXIT
32
92
31
34
BATTERY ROOM
26
33
24
I
T X E
109
92
213
65
25
23
41
HVAC DUCTING (350x250) TO FLOOR LEVEL
EYE WASH 265-EW8301
CO2 4.5 kg
265-FEXXXX (HOLD-1)
18
21
29
27
28
44
UPS, INST. & TELE. ROOM
180
43
42
19
170
171
172
173
174
175
206
205
204
203
201
202
207
20
22
30
208
105
84
107
64
I
T X E
92
38
181
210
A
CO2 4.5 kg
265-FEXXXX (HOLD-1)
1 7 3
I
D O V R O O L F O T
) 0 0 2 x 0 0 3 (
I
G N T C U D C A V H
0 0 3 4
TOILET
AIR LOCK
EXIT
106
176
177
178
I
T X E
92
95
94
FB
104
83
212
179
113
B
FB 265-XZ8344
265-XZ8357
ESK
265-XZ8349
FLOOR PLAN VIEW EL.+22160 T.O.F (SECOND FLOOR)
EQUIPMENT LIST FOR UPS / INSTRUMENT / TELECOM ROOM (LER 2ND FLOOR)
SI.NO.
TAG NUMBER
DESCRIPTION
DIMENSIONS (MM)
LENGTH
WIDTH
HEIGHT
WEIGHT (KG)
TYPE OF MOUNTING
ELECTRICAL EQUIPMENT LIST
18
19
20
21
22
27
28
29
30
35
36
37
38
42
43
44
83
84
92
94
95
104
105
106
107
113
64
170
171
172
173
174
175
176
177
178
179
180
181
201
202
203
204
205
206
207
208
210
212
AC UPS SYSTEM A
AC UPS SYSTEM B
AC UPS DISTRIBUTION BOARD A
AC UPS DISTRIBUTION BOARD B
AC UPS BATTERY MONITORING SYSTEM
DC UPS BATTERY CHARGER
DC UPS DISTRIBUTION BOARD A
DC UPS DISTRIBUTION BOARD B
DC UPS BATTERY MONITORING SYSTEM
NAVIGATIONAL AIDS UPS A
NAVIGATIONAL AIDS UPS B
MAIN DISTRIBUTION BOARD NAV - AID UPS
NAV AID BATTERY MONITORING SYSTEM
LIGHTING & SMALL POWER DB
POWER DISTRIBUTION BOARD
HELIDECK LIGHTING MAIN CONTROL PANEL
3000
3000
1600
1600
600
2940
1200
1200
600
1200
1600
800
600
1000
800
800
LOSPE EQUIPMENT LIST
NOVEC LOCAL STATUS PANEL 3
NOVEC LOCAL STATUS PANEL 4
6.8KG CO2 EXTINGUISHER 2 NO’S
FIRST AID KIT
FIRE BLANKET
NOVEC INDOOR PUSH BUTTON & LAMP PANEL
NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL
NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL
NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL
ELECTRICAL SAFETY KIT
300
300
178 DIA
448
300
450
450
450
450
1000
HVAC EQUIPMENT LIST
1000
1000
800
800
400
1000
800
800
400
800
800
800
400
500
500
800
150
150
213
500
300
300
300
300
400
2200
2200
2000
2000
1000
2200
2000
2000
1000
2200
2200
2450
1000
1200
1400
1000
300
300
1225
425
1200
450
450
450
450
3750
3750
500
500
100
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
2000
FLOOR MOUNTED
400
400
100
550
550
100
100
300
125
160
15
15
23
15
10
40
40
40
40
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
1800
145
FLOOR MOUNTED
HVAC PURGE PANEL FOR UPS, INSTRUMENT ADN TELECOM ROOM - LER 2ND FLOOR
600
500
1000
200
WALL MOUNTED
INSTRUMENT EQUIPMENT LIST
DCS MARSHALLING CABINET-1
DCS SYSTEM CABINET-1
DCS MARSHALLING CABINET-2
DCS MARSHALLING CABINET-3
DCS SYSTEM CABINET-2
DCS MARSHALLING CABINET-4
FUTURE CABINET-1
ICSS NETWORK CABINET
ICSS SERVER CABINET
HSSD PANEL-3
HSSD PANEL-4
DCS CONSOLE (OWS / EWS / AUX)
TELECOM CABINET -1
TELECOM CABINET -2
TELECOM CABINET -3
TELECOM CABINET -4
PROCESS CCTV CABINET
PA/GA SYSTEM CABINET
FUTURE TELECOM CABINET
TELECOM PDB
TELECOM CONSOLE - 1
ACS ENCLOSURE
800
800
800
800
800
800
800
800
800
600
600
2200
TELECOM EQUIPMENT LIST
800
800
800
800
800
800
800
1400
1900
616
800
800
800
800
800
800
800
1000
1000
300
300
800
800
1000
800
800
800
800
800
400
600
300
2100
2100
2100
2100
2100
2100
2100
2100
2100
600
600
770
2100
2100
2100
2100
2100
2100
2100
1500
1690
616
450
450
450
450
450
450
450
450
150
150
300
350
400
350
350
250
350
200
300
80
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
WALL MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
FLOOR MOUNTED
WALL MOUNTED
SI.NO.
TAG NUMBER
DESCRIPTION
DIMENSIONS (MM)
LENGTH
WIDTH
HEIGHT
WEIGHT (KG)
TYPE OF MOUNTING
EQUIPMENT LIST FOR BATTERY ROOM (LER 2ND FLOOR)
ELECTRICAL EQUIPMENT LIST
23
24
25
26
31
32
33
34
39
40
41
213
92
109
65
AC UPS A MCCB BOX
AC UPS B MCCB BOX
AC UPS A BATTERY BANK
AC UPS B BATTERY BANK
DC UPS A MCCB BOX
DC UPS B MCCB BOX
DC UPS A BATTERY BANK
DC UPS B BATTERY BANK
NAV - AID UPS ISOLATION SWITCH (Ex’de”)
NAV - AID UPS BATTERY BANK
BATTERY LIFTING TROLLEY
500
500
3920
3920
500
500
1700
1700
500
1500
1050
300
300
800
800
300
300
800
800
300
900
650
600
600
1540
1540
600
600
1400
1400
600
1130
1600
TELECOM EQUIPMENT LIST
ACS ENCLOSURE
616
300
616
LOSPE EQUIPMENT LIST
6.8KG CO2 EXTINGUISHER 2 NO’S
PORTABLE EYE WASH
178 DIA
300
250
1225
300
HVAC EQUIPMENT LIST
100
100
6200
6200
100
100
1140
1140
125
1220
100
80
23
10
WALL MOUNTED
WALL MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
WALL MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
FLOOR MOUNTED
PORTABLE
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
HVAC PURGE PANEL FOR INSTRUMENT ROOM - LER 2ND FLOOR
600
500
1000
200
WALL MOUNTED
NOTES: 1.
ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS UNLESS STATED OTHERWISE.
THIS LAYOUT SHALL BE USED ONLY FOR QUANTITY AND LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENT AND DIRECTION OF ESCAPE ROUTES.
A
PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT, SECONDARY ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.)
NOVEC 1230 (FK-5-1-12) CLEAN AGENT SYSTEM PROTECTION SHALL BE PROVIDED FOR ELECTRICAL & INSTRUMENT ROOM AND UPS, INSTRUMENT AND TELECOM ROOM IN THE LER.
LOCATION OF FIREFIGHTING, SAFETY & LIFESAVING EQUIPMENT INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION.
B
ALL FIRE & SAFETY EQUIPMENT SHALL BE LOCATED IN SUCH A WAY THAT THEY ARE EASILY ACCESSIBLE.
AIR LOCK ROOM SHOULD ALLOW SAFE MANEUVERING OF AN INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.
LEGENDS:
LEGEND
DESCRIPTIONS
QTY
CO2 4.5 kg
FB
4.5kg CO2 PORTABLE FIRE EXTINGUISHER
FIRE BLANKET
FIRST AID KIT
EYE WASH
PORTABLE EYE WASH
ESK
ELECTRICAL SAFETY KIT
4
1
1
1
1
HOLDS: 1.
TAG NOS.
KEY PLAN
0 5 7 3
0 0 0 2 1
0 0 5 5
1225
HOLD-1
0 0 0 4 1
6500
0 0 5 2
4000
4000
0 0 2 2
2225
16000
17000
6210
FUTRE DECK EXTENSION
16 Mx 3.75 M
14.5, x 2M
MIN. CRANE RADIUS 6.7M
2200
0 0 5 3
8 1 7 5
2000
2000
R O T A L U M U C C A
X X X
5 6 2
I
D K S
0 0 3 3
HPU PLC PANEL
800
0 0 8
265-XXX HOLD-1
4000
0 0 0 2
0 0 0 2 1
0 7 5 1
0 0 0 8
0 5 6 7
BOS.EL.20850 MONORAIL CAP. 2 T
2800mmx2300mm LAYDOWN AREA CAP. 2T
5 3 1 5 1
HOLD-2
4860
THIS DRAWING
200-20-SH-DEC-00013
265-91-EL-PLN-00001
REFERENCE No.
TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT ELECTRICAL EQUIPMENT LAYOUT LOCAL EQUIPMENT ROOM (LER) FOR WHP13N
TITLE
REFERENCES
A
A1
NO.
ISSUED FOR REVIEW
ISSUED FOR IDC
DESCRIPTION
DP
MTA
JB
JB
BPB
09/04/25
BPB
24/03/25
BY
CHKD
APVD
DATE
PROJECT TITLE :
REVISIONS
NFPS Offshore Riser Platforms & Intrafield Pipelines Project - COMP3
Qatar Energy LNG
Qatar Energy LNG
THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.
CONSULTANT / CONTRACTOR :
Saipem S.p.A.
CONTRACTOR DRAWING NO:
033764-M-D00-18-SPM-LP-D-00046-0001
TITLE :
FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - LOCAL EQUIPMENT ROOM - WHP13N
SCALE :
1:50
PROJECT NO. :
LTC/C/NFP/5129/20
PROJECT
033764
DRAWING NO.
SHT
SIZE REVISION
265-83-SH-PLN-00004
0002
A1
A
C
D
E
F
G
H
I
J
K
L
1
2
3
4
5
6
7
10
11
12
13
14
15
16
Project: Q-32705 - Saipem COMP3 Folder: RFQ Files