Infinity

Not logged in
Home

❯

Reference Examples

❯

Q 32705 Saipem COMP3

❯

RFQ Files

❯

265 83 SH PLN 00004_A

Classification: Internal

1

2

3

4

5

6

7

8

9

11

12

13

14

15

16

A

B

C

D

E

F

G

H

I

J

K

L

B

2

7500

B

3550

HVAC DUCTING (300x200) TO FLOOR VOID

9150

61

12

13

3

1

DH

16

17

5

6

7

8

132

2

152

151

150

14

141

140

211

82 101

EXIT

95

94

F B

92

ELECTRICAL & INSTRUMENT ROOM

56

131

130

R O F E C A P S D E T A C O L L A

L O O T F O E G A R O T S

R O F E C A P S D E T A C O L L A

Y A R T E L B A C L A C R T C E L E

I

153

154

155

156

157

158

159

160

200

I

T X E

92

100

81

112

ESK

161

162

15

134

133

62

102

ALLOCATED SPACE FOR INST. / TELE. CABLE TRAY

A

L L A W T S A L B E R F

I

/

A

0 0 0 4 1

0 0 3 4

CO2 4.5 kg

265-FEXXXX (HOLD-1)

FB

265-XZ8343

1

265-XZ8356

182

72

209

163

TEMPORARY REFUGE AREA (0.6 SQM x 30 POB )

71

75

80

79

73

93

90

94

57

92

EXIT

B

BAM 10

265-XZXXXX (HOLD-1)

BA

265-XZ8306

BAM 10

265-XZXXXX (HOLD-1)

AIR LOCK ROOM

EXIT

103

0 0 8 1

7 4 3

FLOOR PLAN VIEW EL.+17253 T.O.F (FIRST FLOOR)

347

2700

350

PRODUCTION DECK EL. +16350 T.O.S

10

QTY

3

3

1

2

1

2

1

1

LEGEND

DESCRIPTIONS

CO2 4.5 kg

BAM 10

BA

4.5kg CO2 PORTABLE FIRE EXTINGUISHER

BREATHING AIR MANIFOLD CABINET WITH 10 NUMBERS OF HOSE UNIT (NOTE-2)

BREATHING APPARATUS ESCAPE SET (15 MINUTES AND 3L CYLINDER)

STRETCHER

FB

FIRE BLANKET

FIRST AID KIT

ESK

ELECTRICAL SAFETY KIT

OXYGEN


FULL CYLINDER

OXYGEN CYLINDER WITH THE MASK

CO2 4.5 kg

265-FEXXXX (HOLD-1)

ESK 265-XZ8348

BAM 10

265-XZXXXX (HOLD-1)

X2

265-XZ8352 265-XZ8353

OXYGEN


FULL CYLINDER

265-XZ8362

265-XZ8355

265-FEXXXX (HOLD-1)

CO2 4.5 kg

EQUIPMENT LIST FOR ELECTRICAL & INSTRUMENT ROOM (LER 1ST FLOOR)

SI.NO.

TAG NUMBER

DESCRIPTION

DIMENSIONS (MM)

LENGTH

WIDTH

HEIGHT

WEIGHT (KG)

TYPE OF MOUNTING

ELECTRICAL EQUIPMENT LIST

1

2

3

5

6

7

8

12

13

14

15

16

17

56

61

62

150

151

152

153

154

155

156

157

158

159

160

161

162

211

140

141

81

82

92

94

95

100

101

102

112

130

131

132

133

134

265-SB-91601

MEDIUM VOLTAGE SWITCHBOARD (11KV)

265-MCC-91301

LV MOTOR CONTROL CENTER

265-TR-91301

TRANSFORMER

265-LP-91301

LIGHTING & SMALL POWER DISTRIBUTION PANEL

265-PDB-91301

AC POWER DISTRIBUTION BOARD

265-PDB-91303

AC POWER DISTRIBUTION BOARD

265-PDB-91304

AC POWER DISTRIBUTION BOARD

CP-260101

SUBSEA CABLE MONITORING

PD MONITORING PANEL

IMCS PANEL

KEY ONLINE DIAGRAM FRAME

265-CBT-4101-01

LIFTING TRUCK FOR ACB

265-CBT-4101-02

LIFTING TRUCK FOR VCB

PADLOCK KEY BOX

1670

8850

1800

1000

800

800

800

600

300

800

1000

1000

1000

250

HVAC EQUIPMENT LIST

265-ACP-42301

HVAC CONTROL PANEL

1200

600

HVAC PURGE PANEL FOR ELECTRICAL ROOM - LER 1ST FLOOR

INSTRUMENT EQUIPMENT LIST

IRP

ICSS PDB

FUTURE CABINET-1

ESD SYSTEM CABINET-1

ESD MARSHALLING CABINET-1

ESD SYSTEM CABINET-2

ESD MARSHALLING CABINET-2

F&G SYSTEM CABINET-1

F&G MARSHALLING CABINET-1

F&G SYSTEM CABINET-2

F&G MARSHALLING CABINET-2

HSSD PANEL-1

HSSD PANEL-2

800

800

800

800

800

800

800

800

800

800

800

600

600

TELECOM EQUIPMENT LIST

ACS ENCLOSURE

616

MECHANICAL EQUIPMENT LIST

MEG PUMP VFD A

265-TCP-8701

THYRISTOR CONTROL PANEL

800

1000

LOSPE EQUIPMENT LIST

NOVEC LOCAL STATUS PANEL 1

NOVEC LOCAL STATUS PANEL 2

6.8KG CO2 EXTINGUISHER (2 NO.)

FIRST AID KIT

FIRE BLANKET

NOVEC INDOOR PUSH BUTTON & LAMP PANEL

NOVEC INDOOR PUSH BUTTON & LAMP PANEL

NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL

ELECTRICAL SAFETY KIT

300

300

178 DIA

448

300

450

450

450

1000

ARCHITECTURAL EQUIPMENT LIST

FILE CABINET-1

FILE CABINET-2

FILE CABINET-3

TABLE WITH CHAIRS

REFRIGERATOR

600

600

800

650

1765

1600

1300

500

500

500

500

600

200

800

50

750

750

100

800

500

800

800

800

800

800

800

800

800

800

800

800

300

300

300

800

400

150

150

213

500

300

300

300

400

450

450

500

600

2800

2300

2200

1200

1400

1400

1400

2000

500

2200

700

1800

1158

350

2100

1000

2100

2100

2100

2100

2100

2100

2100

2100

2100

2100

2100

600

600

2332

FLOOR MOUNTED

13560

FLOOR MOUNTED

2050

FLOOR MOUNTED

300

125

125

125

450

150

300

10

110

90

10

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

FLOOR MOUNTED

WALL MOUNTED

FLOOR MOUNTED

WALL MOUNTED

PORTABLE

PORTABLE

WALL MOUNTED

1000

FLOOR MOUNTED

200

WALL MOUNTED

450

450

450

450

450

450

450

450

450

450

150

150

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

WALL MOUNTED

WALL MOUNTED

616

80

WALL MOUNTED

2100

2200

300

300

1225

425

1200

450

450

450

350

450

FLOOR MOUNTED

FLOOR MOUNTED

15

15

23

15

10

40

40

40

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

1800

145

FLOOR MOUNTED

1880

1880

1200

1200

100

100

100

150

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

EQUIPMENT LIST FOR TEMPORARY REFUGE (LER 1ST FLOOR)

SI.NO.

TAG NUMBER

DESCRIPTION

DIMENSIONS (MM)

LENGTH

WIDTH

HEIGHT

WEIGHT (KG)

TYPE OF MOUNTING

163

182

209

71

72

73

75

79

80

90

92

93

94

103

57

INSTRUMENT EQUIPMENT LIST

DCS CONSOLE (OWS )

MULTI -GAS DETECTOR

1000

455

800

450

770

640

200

FLOOR MOUNTED

FLOOR MOUNTED

TELECOM EQUIPMENT LIST

TELECOM CONSOLE - 2

800

600

1690

150

FLOOR MOUNTED

LOSPE EQUIPMENT LIST

BREATHING AIR MANIFOLD A

BREATHING AIR MANIFOLD B

BREATHING AIR MANIFOLD C

ESCAPE BREATHING APPARATUS CABINET

NOVEC MAIN JB

NOVEC CONTROL PANEL

OXYGEN CYLINDER WITH MASK

6.8KG CO2 EXTINGUISHER

STRETCHER 2 NO’S

FIRST AID KIT

NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL

1500

1500

1500

750

800

600

300

178 DIA

300

448

450

GENERAL EQUIPMENT LIST

610

610

610

600

450

450

300

500

213

300

960

960

960

857

1500

1200

1000

1225

1200

425

450

150

150

150

224

120

120

20

23

50

15

40

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

PORTABLE

NOTES: 1.

ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS UNLESS STATED OTHERWISE.

BREATHING AIR MANIFOLD 30 PERSON IS PROVIDED, AS PER TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).

A

THIS LAYOUT SHALL BE USED ONLY FOR QUANTITY AND LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENT AND DIRECTION OF ESCAPE ROUTES.

PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT, SECONDARY ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.)

NOVEC 1230 (FK-5-1-12) CLEAN AGENT SYSTEM PROTECTION SHALL BE PROVIDED FOR ELECTRICAL & INSTRUMENT ROOM AND UPS, INSTRUMENT AND TELECOM ROOM IN THE LER.

B

LOCATION OF FIREFIGHTING, SAFETY & LIFESAVING EQUIPMENT INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION.

ALL FIRE & SAFETY EQUIPMENT SHALL BE LOCATED IN SUCH A WAY THAT THEY ARE EASILY ACCESSIBLE.

OXYGEN CYLINDER WITH FACE MASK FOR CPR PURPOSE SHALL BE PROVIDED INSIDE BUILDING (IN TEMPORARY REFUGE).

FOR TEMPORARY REFUGE, AN OVERALL FREE FLOOR SPACE OF 18 M² (0.6 M2 /PERSON x POB (30 NOS.)) FOR PERSONNEL MUSTERING SHALL BE MAINTAINED IN THE TR.

  1. AIR LOCK ROOM SHOULD ALLOW SAFE MANEUVERING OF AN

INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.

HOLDS: 1.

TAG NOS.

KEY PLAN

0 5 7 3

0 0 0 2 1

0 0 5 5

1225

HOLD-1

0 0 0 4 1

6500

0 0 5 2

4000

4000

0 0 2 2

2225

16000

17000

6210

FUTRE DECK EXTENSION

16 Mx 3.75 M

14.5, x 2M

MIN. CRANE RADIUS 6.7M

2200

0 0 5 3

8 1 7 5

2000

2000

R O T A L U M U C C A

X X X

5 6 2

I

D K S

0 0 3 3

HPU PLC PANEL

800

0 0 8

265-XXX HOLD-1

4000

0 0 0 2

0 0 0 2 1

0 7 5 1

0 0 0 8

0 5 6 7

BOS.EL.20850 MONORAIL CAP. 2 T

2800mmx2300mm LAYDOWN AREA CAP. 2T

5 3 1 5 1

HOLD-2

4860

THIS DRAWING

200-20-SH-DEC-00013

265-91-EL-PLN-00001

REFERENCE No.

TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT ELECTRICAL EQUIPMENT LAYOUT LOCAL EQUIPMENT ROOM (LER) FOR WHP13N

TITLE

REFERENCES

A

A1

NO.

ISSUED FOR REVIEW

ISSUED FOR IDC

DESCRIPTION

DP

MTA

JB

JB

BPB

09/04/25

BPB

24/03/25

BY

CHKD

APVD

DATE

REVISIONS

C

D

E

F

G

H

I

J

K

L

WALL MOUNTED

PROJECT TITLE :

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

NFPS Offshore Riser Platforms & Intrafield Pipelines Project - COMP3

Qatar Energy LNG

PORTABLE HANDLAMP

300

200

350

3

WALL MOUNTED

Qatar Energy LNG

THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.

CONSULTANT / CONTRACTOR :

Saipem S.p.A.

CONTRACTOR DRAWING NO:

033764-M-D00-18-SPM-LP-D-00046-0001

TITLE :

FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - LOCAL EQUIPMENT ROOM - WHP13N

SCALE :

1:50

PROJECT NO. :

LTC/C/NFP/5129/20

PROJECT

033764

DRAWING NO.

SHT

SIZE REVISION

265-83-SH-PLN-00004

0001

A1

A

1

2

3

4

5

6

7

10

11

12

13

14

15

16

Classification: Internal

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

2

A

1

CO2 4.5 kg

265-FEXXXX (HOLD-1)

A

B

C

D

E

F

G

H

I

J

K

L

B

1200

I

D O V R O O L F O T

) 0 0 2 x 0 0 3 (

I

G N T C U D C A V H

40

39

35

37

36

L L A W T S A L B E R F

/

I

0 0 0 4 1

Y A R T E L B A C L A C R T C E L E

I

R O F E C A P S D E T A C O L L A

(HOLD-1) 265-FEXXXX

CO2 4.5 kg

B 9900

9200

EXIT

32

92

31

34

BATTERY ROOM

26

33

24

I

T X E

109

92

213

65

25

23

41

HVAC DUCTING (350x250) TO FLOOR LEVEL

EYE WASH 265-EW8301

CO2 4.5 kg

265-FEXXXX (HOLD-1)

18

21

29

27

28

44

UPS, INST. & TELE. ROOM

180

43

42

19

170

171

172

173

174

175

206

205

204

203

201

202

207

20

22

30

208

105

84

107

64

I

T X E

92

38

181

210

A

CO2 4.5 kg

265-FEXXXX (HOLD-1)

1 7 3

I

D O V R O O L F O T

) 0 0 2 x 0 0 3 (

I

G N T C U D C A V H

0 0 3 4

TOILET

AIR LOCK

EXIT

106

176

177

178

I

T X E

92

95

94

FB

104

83

212

179

113

B

FB 265-XZ8344

265-XZ8357

ESK

265-XZ8349

FLOOR PLAN VIEW EL.+22160 T.O.F (SECOND FLOOR)

EQUIPMENT LIST FOR UPS / INSTRUMENT / TELECOM ROOM (LER 2ND FLOOR)

SI.NO.

TAG NUMBER

DESCRIPTION

DIMENSIONS (MM)

LENGTH

WIDTH

HEIGHT

WEIGHT (KG)

TYPE OF MOUNTING

ELECTRICAL EQUIPMENT LIST

18

19

20

21

22

27

28

29

30

35

36

37

38

42

43

44

83

84

92

94

95

104

105

106

107

113

64

170

171

172

173

174

175

176

177

178

179

180

181

201

202

203

204

205

206

207

208

210

212

AC UPS SYSTEM A

AC UPS SYSTEM B

AC UPS DISTRIBUTION BOARD A

AC UPS DISTRIBUTION BOARD B

AC UPS BATTERY MONITORING SYSTEM

DC UPS BATTERY CHARGER

DC UPS DISTRIBUTION BOARD A

DC UPS DISTRIBUTION BOARD B

DC UPS BATTERY MONITORING SYSTEM

NAVIGATIONAL AIDS UPS A

NAVIGATIONAL AIDS UPS B

MAIN DISTRIBUTION BOARD NAV - AID UPS

NAV AID BATTERY MONITORING SYSTEM

LIGHTING & SMALL POWER DB

POWER DISTRIBUTION BOARD

HELIDECK LIGHTING MAIN CONTROL PANEL

3000

3000

1600

1600

600

2940

1200

1200

600

1200

1600

800

600

1000

800

800

LOSPE EQUIPMENT LIST

NOVEC LOCAL STATUS PANEL 3

NOVEC LOCAL STATUS PANEL 4

6.8KG CO2 EXTINGUISHER 2 NO’S

FIRST AID KIT

FIRE BLANKET

NOVEC INDOOR PUSH BUTTON & LAMP PANEL

NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL

NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL

NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL

ELECTRICAL SAFETY KIT

300

300

178 DIA

448

300

450

450

450

450

1000

HVAC EQUIPMENT LIST

1000

1000

800

800

400

1000

800

800

400

800

800

800

400

500

500

800

150

150

213

500

300

300

300

300

400

2200

2200

2000

2000

1000

2200

2000

2000

1000

2200

2200

2450

1000

1200

1400

1000

300

300

1225

425

1200

450

450

450

450

3750

3750

500

500

100

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

WALL MOUNTED

2000

FLOOR MOUNTED

400

400

100

550

550

100

100

300

125

160

15

15

23

15

10

40

40

40

40

FLOOR MOUNTED

FLOOR MOUNTED

WALL MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

1800

145

FLOOR MOUNTED

HVAC PURGE PANEL FOR UPS, INSTRUMENT ADN TELECOM ROOM - LER 2ND FLOOR

600

500

1000

200

WALL MOUNTED

INSTRUMENT EQUIPMENT LIST

DCS MARSHALLING CABINET-1

DCS SYSTEM CABINET-1

DCS MARSHALLING CABINET-2

DCS MARSHALLING CABINET-3

DCS SYSTEM CABINET-2

DCS MARSHALLING CABINET-4

FUTURE CABINET-1

ICSS NETWORK CABINET

ICSS SERVER CABINET

HSSD PANEL-3

HSSD PANEL-4

DCS CONSOLE (OWS / EWS / AUX)

TELECOM CABINET -1

TELECOM CABINET -2

TELECOM CABINET -3

TELECOM CABINET -4

PROCESS CCTV CABINET

PA/GA SYSTEM CABINET

FUTURE TELECOM CABINET

TELECOM PDB

TELECOM CONSOLE - 1

ACS ENCLOSURE

800

800

800

800

800

800

800

800

800

600

600

2200

TELECOM EQUIPMENT LIST

800

800

800

800

800

800

800

1400

1900

616

800

800

800

800

800

800

800

1000

1000

300

300

800

800

1000

800

800

800

800

800

400

600

300

2100

2100

2100

2100

2100

2100

2100

2100

2100

600

600

770

2100

2100

2100

2100

2100

2100

2100

1500

1690

616

450

450

450

450

450

450

450

450

150

150

300

350

400

350

350

250

350

200

300

80

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

WALL MOUNTED

WALL MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

WALL MOUNTED

FLOOR MOUNTED

WALL MOUNTED

SI.NO.

TAG NUMBER

DESCRIPTION

DIMENSIONS (MM)

LENGTH

WIDTH

HEIGHT

WEIGHT (KG)

TYPE OF MOUNTING

EQUIPMENT LIST FOR BATTERY ROOM (LER 2ND FLOOR)

ELECTRICAL EQUIPMENT LIST

23

24

25

26

31

32

33

34

39

40

41

213

92

109

65

AC UPS A MCCB BOX

AC UPS B MCCB BOX

AC UPS A BATTERY BANK

AC UPS B BATTERY BANK

DC UPS A MCCB BOX

DC UPS B MCCB BOX

DC UPS A BATTERY BANK

DC UPS B BATTERY BANK

NAV - AID UPS ISOLATION SWITCH (Ex’de”)

NAV - AID UPS BATTERY BANK

BATTERY LIFTING TROLLEY

500

500

3920

3920

500

500

1700

1700

500

1500

1050

300

300

800

800

300

300

800

800

300

900

650

600

600

1540

1540

600

600

1400

1400

600

1130

1600

TELECOM EQUIPMENT LIST

ACS ENCLOSURE

616

300

616

LOSPE EQUIPMENT LIST

6.8KG CO2 EXTINGUISHER 2 NO’S

PORTABLE EYE WASH

178 DIA

300

250

1225

300

HVAC EQUIPMENT LIST

100

100

6200

6200

100

100

1140

1140

125

1220

100

80

23

10

WALL MOUNTED

WALL MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

WALL MOUNTED

WALL MOUNTED

FLOOR MOUNTED

FLOOR MOUNTED

WALL MOUNTED

FLOOR MOUNTED

PORTABLE

WALL MOUNTED

WALL MOUNTED

WALL MOUNTED

HVAC PURGE PANEL FOR INSTRUMENT ROOM - LER 2ND FLOOR

600

500

1000

200

WALL MOUNTED

NOTES: 1.

ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS UNLESS STATED OTHERWISE.

THIS LAYOUT SHALL BE USED ONLY FOR QUANTITY AND LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENT AND DIRECTION OF ESCAPE ROUTES.

A

PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT, SECONDARY ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.)

NOVEC 1230 (FK-5-1-12) CLEAN AGENT SYSTEM PROTECTION SHALL BE PROVIDED FOR ELECTRICAL & INSTRUMENT ROOM AND UPS, INSTRUMENT AND TELECOM ROOM IN THE LER.

LOCATION OF FIREFIGHTING, SAFETY & LIFESAVING EQUIPMENT INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION.

B

ALL FIRE & SAFETY EQUIPMENT SHALL BE LOCATED IN SUCH A WAY THAT THEY ARE EASILY ACCESSIBLE.

AIR LOCK ROOM SHOULD ALLOW SAFE MANEUVERING OF AN INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.

LEGENDS:

LEGEND

DESCRIPTIONS

QTY

CO2 4.5 kg

FB

4.5kg CO2 PORTABLE FIRE EXTINGUISHER

FIRE BLANKET

FIRST AID KIT

EYE WASH

PORTABLE EYE WASH

ESK

ELECTRICAL SAFETY KIT

4

1

1

1

1

HOLDS: 1.

TAG NOS.

KEY PLAN

0 5 7 3

0 0 0 2 1

0 0 5 5

1225

HOLD-1

0 0 0 4 1

6500

0 0 5 2

4000

4000

0 0 2 2

2225

16000

17000

6210

FUTRE DECK EXTENSION

16 Mx 3.75 M

14.5, x 2M

MIN. CRANE RADIUS 6.7M

2200

0 0 5 3

8 1 7 5

2000

2000

R O T A L U M U C C A

X X X

5 6 2

I

D K S

0 0 3 3

HPU PLC PANEL

800

0 0 8

265-XXX HOLD-1

4000

0 0 0 2

0 0 0 2 1

0 7 5 1

0 0 0 8

0 5 6 7

BOS.EL.20850 MONORAIL CAP. 2 T

2800mmx2300mm LAYDOWN AREA CAP. 2T

5 3 1 5 1

HOLD-2

4860

THIS DRAWING

200-20-SH-DEC-00013

265-91-EL-PLN-00001

REFERENCE No.

TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT ELECTRICAL EQUIPMENT LAYOUT LOCAL EQUIPMENT ROOM (LER) FOR WHP13N

TITLE

REFERENCES

A

A1

NO.

ISSUED FOR REVIEW

ISSUED FOR IDC

DESCRIPTION

DP

MTA

JB

JB

BPB

09/04/25

BPB

24/03/25

BY

CHKD

APVD

DATE

PROJECT TITLE :

REVISIONS

NFPS Offshore Riser Platforms & Intrafield Pipelines Project - COMP3

Qatar Energy LNG

Qatar Energy LNG

THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.

CONSULTANT / CONTRACTOR :

Saipem S.p.A.

CONTRACTOR DRAWING NO:

033764-M-D00-18-SPM-LP-D-00046-0001

TITLE :

FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - LOCAL EQUIPMENT ROOM - WHP13N

SCALE :

1:50

PROJECT NO. :

LTC/C/NFP/5129/20

PROJECT

033764

DRAWING NO.

SHT

SIZE REVISION

265-83-SH-PLN-00004

0002

A1

A

C

D

E

F

G

H

I

J

K

L

1

2

3

4

5

6

7

10

11

12

13

14

15

16

Project: Q-32705 - Saipem COMP3 Folder: RFQ Files


Loading authentication...

Graph View

Backlinks

  • 00 Index

Created with Infinity Constructor © 2025

  • Elynox | Go Further