Infinity

Not logged in
Home

❯

Reference Examples

❯

Q 32705 Saipem COMP3

❯

RFQ Files

❯

265 83 SH PLN 00007_A

Classification: Internal

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

PLATFORM NORTH 30°

30°

E H U T R R T O N

N

E H U T R R T O N

PREVAILING WIND

N. 122250

3

0 5 2 8

EMERGENCY LADDER

N. 114000

2

A

0 0 0 0 0 1

.

E

I

O T E N I L E P P D L E F A R T N

I

I

” 8 2

15000

I

E T S O P M O C R O F E B U T

J

” 2 1

3 1 P H W O T N 6 P R M O R F E L B A C

I

N O T A C O L L A E C A P S

N 6 P R O T R E S R

I

” 8 2

)

N 3 1 L P

(

I

F T L P N O S S E R P M O C E R U T U F

)

E R U T U F (

C

0 0 0 5 1 1

.

E

15000

B

0 0 0 0 3 1

.

E

265-XZ8326

265-XZ8327

XXX-FEXXXX (HOLD-1)

9 Kg

TO CELLAR DECK

UP

EDGE OF DECK

15380

3190

T.O.G. EL. +5475

SAFETY GATE

REFER DETAIL-2

BARRICADE WALL

T.O.G. EL. +3707

K C E D F O E G D E

265-XZ8367

n=5

TEMPSC DROP ZONE

0 5 5 7350(L) X 2816(W) 7

LIFE JACKET CABINET 1200 (H) X 800 (W) 400 (D)

SECONDARY BOAT LANDING

APPROACH

T.O.G. EL. +6862

REFER DETAIL-1

NOTE 10

EMERGENCY LADDER

SECONDARY BOAT LANDING T.O.G. EL. +2707

WELLSLOT#01 WELLSLOT#02

WELLSLOT#03 (SPARE)

RIG APPROACH

0 0 0 4 1

K C E D F O E G D E

WELLSLOT#04 WELLSLOT#05

(SPARE)

WELLSLOT#06 (SPARE)

WELLSLOT#07

WELLSLOT#08 WELLSLOT#09

(SPARE)

265-XZ8368

n=5

WELLSLOT#10

WELLSLOT#11

WELLSLOT#12 (SPARE)

N. 100000

1

0 0 2 1

LIFE JACKET CABINET 1200 (H) X 800 (W) 400 (D)

MAX. CRANE RADIUS 35M

EDGE OF DECK

BARRICADE WALL

SAFETY GATE

T.O.G. EL. +5475

UP

TO CELLAR DECK

NOTE 10

T.O.G. EL. +2707

9 Kg

XXX-FEXXXX (HOLD-1)

265-XZ8329

265-XZ8328

DN

I

G N D N A L T A O B

Y R A M R P

I

H C A O R P P A

PRIMARY BOAT LANDING T.O.G. EL. +3707

2000

265-XZ8366

)

E R A P S

(

E B U T

J

” 2 1

:

D O

NOTES:

  1. ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS

UNLESS STATED OTHERWISE.

  1. PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT,

SECONDARY ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.)

  1. THE MINIMUM HEADROOM HEIGHT SHALL BE PROVIDED IN ALL PARTS, MEASURED VERTICALLY FROM DECK SURFACE OF LANDING OR PLATFORM.

  2. THIS LAYOUT SHALL BE USED ONLY FOR QUANTITY AND

LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENT AND DIRECTION OF ESCAPE ROUTES.

  1. THE PORTABLE EXTINGUISHERS LOCATED OUTDOOR SHALL

BE PROVIDED WITH WEATHER-PROOF CABINET.

  1. ARROWS SHOWN ON THE ESCAPE ROUTE INDICATE THE

PREFERRED DIRECTION OF EGRESS TOWARDS THE PRIMARY MUSTER AREA.

  1. LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING

EQUIPMENT AND DIRECTIONAL ARROWS INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION.

  1. STAIRCASES SHOULD ALLOW TRANSPORTATION OF AN

INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.

  1. ALL FIRE & SAFETY EQUIPMENT SHALL BE LOCATED IN SUCH

A WAY THAT THEY ARE EASILY ACCESSIBLE.

  1. A FIXED LADDER (EXISTING) IS PROVIDED ON THE BOAT

A

B

LANDING SO THAT A PERSON WHO FALLS OVERBOARD WILL HAVE A WAY BACK ONTO THE PLATFORM.

C

  1. ALL ESCAPE ROUTES SHALL BE MARKED WITH ESCAPE MARKER PAINTED ON THE FLOOR IN OIL RESISTANT PHOTOLUMINESCENT PAINT THAT IS VISIBLE, DURABLE AND ANTI-SLIP.

  2. AS PER TECHNICAL SAFETY BASIS OF DESIGN

(200-20-SH-DEC-00013) – FOR OUTDOOR AREAS, THE DEAD END SHALL NOT EXCEED 6 M OF TRAVEL DISTANCE.

13.INTERNATIONAL SHIP/SHORE CONNECTION (4 NO’S x 2.5” MALE

BS 336 INSTANTANEOUS COUPLING WITH 6” PIPING CONNECTION) SHALL BE PROVIDED FOR FLEXIBLE HOSE CONNECTION FROM SUPPLY BOAT FOR FIRE WATER SUPPLY TO DRY DELUGE SYSTEM PROVIDED FOR WELLHEAD AREA.

LEGENDS:

LEGEND

9 Kg

DESCRIPTIONS PRIMARY ESCAPE ROUTE 1.12m(WIDTH) X 2.286m(HEAD CLEARANCE) SECONDARY ESCAPE ROUTE 0.76m(WIDTH) X 2.286m(HEAD CLEARANCE) 9 kg POTASSIUM BICARBONATE DRY CHEMICAL POWDER (BC) PORTABLE FIRE EXTINGUISHER

LIFEBUOY WITH LIFELINE

LIFE JACKET

n=5

CABINET FOR 5 UNITS OF LIFE JACKET

INTERNATIONAL SHIP/SHORE CONNECTION (NOTE-13)

QTY

2

4

10

2

1

HOLDS:

  1. TAG NOS.

D

E

F

G

H

I

J

K

L

200-20-SH-DEC-00013

265-23-PI-PLP-00001

REFERENCE No.

TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT EQUIPMENT ARRANGEMENT PLAN TOP OF JACKET LEVEL FOR WHP13N

TITLE

REFERENCES

A

A1

No.

ISSUED FOR REVIEW

ISSUED FOR IDC

DESCRIPTION

DP

MTA

JB

JB

BPB

09/04/25

BPB

25/03/25

BY

CHKD

APVD

DATE

REVISIONS

PROJECT TITLE :

COMP3 - NFPS OFFSHORE RISER / WELLHEAD PLATFORM & INTRAFIELD PIPELINES PROJECT

Qatar Energy LNG

Qatar Energy LNG

THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.

100

0 0 2

100

0 0 2

CONSULTANT / CONTRACTOR :

Saipem S.p.A.

EQUIPMENT LIST

EQUIPMENT NO.

DESCRIPTION

SIZE (MM)

265-XXXXX 265-XXXXX

LIFE JACKET CABINET LIFE JACKET CABINET

1200 (H) X 800 (W) 400 (D) 1200 (H) X 800 (W) 400 (D)

TOP OF JACKET (T.O.S EL.+6830)

1M

0

1M

2M

3M

4M

5M

400

400

TYPICAL DETAIL-1

TYPICAL DETAIL-2

N.T.S

N.T.S

CONTRACTOR DRAWING No. :

033764-M-D00-08-SPM-LP-D-00047-0001

TITLE :

FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - TOP OF JACKET - WHP13N

SCALE :

1:100

PROJECT No. :

LTC/C/NFP/5129/20

PROJECT

033764

DRAWING No.

SHT

SIZE REVISION

265-83-SH-PLN-00007

0001

A1

A

1

2

3

4

5

6

7

10

11

12

13

14

15

16

A

B

C

D

E

F

G

H

I

J

K

L

Project: Q-32705 - Saipem COMP3 Folder: RFQ Files


Loading authentication...

Graph View

Backlinks

  • 00 Index

Created with Infinity Constructor © 2025

  • Elynox | Go Further