Infinity

Not logged in
Home

❯

Reference Examples

❯

Q 32705 Saipem COMP3

❯

RFQ Files

❯

268 83 SH PLN 00001_A

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Classification: Internal

1

PLATFORM NORTH

A

B

C

D

E

F

G

H

I

J

K

L

EQUIPMENT NO. 268-T8701 268-P8703 268-P8704 268-V8701 268-P8701 268-Y9302A/B 1

N

TRUE NORTH

TRUE NORTH

PREVAILING WIND

45°

A

B

C

15000

15000

3000

7500

268-XZ8313

XXX-XZXXXX (HOLD-1)

BAM 6

XXX-FEXXXX (HOLD-1)

9 Kg

LAYDOWN AREA CAP.1MT

268-XZ8314

4000

3500

1500

O T

I

N A M

K C E D

BOAT POWER SUPPLY JB

0 0 3 2

0 0 3 2

0 0 3 2

0 0 3 2

0 0 3 2

2000

0 0 0 3

SPLICE

BOX

SPLITTER BOX

TOS.+12000

2 1 °

° 8 3

I

G N L L U P E L B A C

Y R A R O P M E T R O F E C A P S

R O F T N E M P U Q E

I

268-P8701

COAMED AREA

M O R F

T E K C A J

L E V E L

268-V8701

268-T8701

PIPING AREA

268-P8704

3 0 7 8 P

8 6 2

0 0 5 4

0 0 5 7

0 0 0 7

0 0 0 7

0 0 1 2

LADDER TO MAIN DECK

TOS.+10000

T E K C A J

L E V E L

M O R F

SPLICE

BOX

0 5 5

MONORAIL MR-MD-11 CAP 1MT

2000

0 0 0 3

268-Y9302B

1500

268-XZ8315

28” PIPILINE FROM WHP13N

(FUTURE)

28” PIPILINE FROM WHP13N

28” PIPILINE FROM RP5N

0 0 0 4 1

8” FUEL GAS PIPE LINE

FROM SUBSEA SKID

2

1

710

790

268-Y9302A

SPLICE

BOX

SPLITTER

BOX

2200

2250

3500

4000

7500

6400

4250

AFFF 135 L

XXX-FEXXXX (HOLD-1)

XXX-FEXXXX (HOLD-1)

9 Kg

O T

I

N A M

K C E D

CELLAR DECK (T.O.S EL. +10000)

TOS.+12200

200-20-SH-DEC-00013

TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT

268-23-PI-PLP-00002

EQUIPMENT ARRANGEMENT PLAN CELLAR DECK FOR RP6N

REFERENCE NO.

TITLE

REFERENCES

A

A1

No.

ISSUED FOR REVIEW

ISSUED FOR IDC

DESCRIPTION

REVISIONS

Digitally si gn ed b y Val en ti na Brusati DN: c n=V alentina B rusati , o= Saipem, ou, email =valentina. bru sati@saip em. com, c= IT Date: 2025. 04.15 14:11:47 +02’ 00’

Gabrie ll a Alma sio

Al ma sio, E = gabrie lla .al masi o@sa ipem .co m Re aso n: I ha ve re vie w ed this docu ment Loca tion :

VB

VB

BY

GA

GA

BPB

15/04/25

BPB

09/04/25

CHKD

APVD

DATE

PROJECT TITLE :

COMP3 - NFPS OFFSHORE RISER / WELLHEAD PLATFORM & INTRAFIELD PIPELINES PROJECT

Qatar Energy LNG

Qatar Ene rgy LNG

THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.

CONSULTANT / CONTRACTOR :

Saipem S.p.A.

268-XZ8316

100

0 0 2

100

0 0 2

400

400

TYPICAL DETAIL-1

TYPICAL DETAIL-2

TITLE :

N.T.S

N.T.S

CONTRACTOR DRAWING No. :

033764-L-D00-11-SPM-LP-D-00044-0001

FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - CELLAR DECK - RP6N

SCALE :

1:100

PROJECT No. :

LTC/C/NFP/5129/20

PROJECT

033764

DRAWING No.

SHT

SIZE REVISION

268-83-SH-PLN-00001

0001

A1

A

EQUIPMENT LIST

DESCRIPTION

OPEN DRAIN TANK OPEN DRAIN WATER PUMP OPEN DRAIN OIL PUMP CLOSED DRAIN DRUM CLOSED DRAIN TRANSFER PUMP TOPSIDE UMBILICAL TERMINATION UNIT

SIZE (MM)

3000(L) x 2300(W) x 2000(H) 1800(L) x 1400(W) x800(H) 1800(L) x 1400(W) x800(H) 1400(ID) x 3500 (TL/TL) 2321(L) x 1550(W) x2260(H) 2500(L) x 700(W) x 1900(H)

2

3

4

5

6

7

10

11

12

13

14

15

16

NOTES:

  1. ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS

UNLESS STATED OTHERWISE.

  1. PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT,

SECONDARY ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.)

A

  1. THE MINIMUM HEADROOM HEIGHT SHALL BE PROVIDED IN ALL

AREA, MEASURED VERTICALLY FROM DECK SURFACE OF LANDING OR PLATFORM.

  1. THIS LAYOUT SHALL BE USED ONLY FOR ESCAPE ROUTE QUANTITY AND LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENTS.

  2. AS PER TECHNICAL SAFETY BASIS OF DESIGN

(200-20-SH-DEC-00013), FOR OUTDOOR AREAS, THE DEAD END SHALL NOT EXCEED 6 M OF TRAVEL DISTANCE.

  1. THE PORTABLE EXTINGUISHERS LOCATED OUTDOOR SHALL BE

PROVIDED WITH WEATHER-PROOF CABINET.

  1. WHEELED EXTINGUISHERS LOCATED OUTDOOR SHALL BE

PROVIDED WITH A UV-RESISTANT RED-VINYL COVER.

  1. ARROWS SHOWN ON THE ESCAPE ROUTE DRAWING INDICATE

THE PREFERRED DIRECTION OF EGRESS TOWARDS THE MUSTER AREA. IN CASE OF EMERGENCY AT RP6N, PERSONNEL SHALL USE BRIDGE TO REACH PRIMARY MUSTER AREA LOCATED AT WELLHEAD PLATFORM LER BUILDING TR. IN CASE ESCAPE THROUGH BRIDGE TOWARDS WELLHEAD IS NOT FEASIBLE, PERSONNEL TO PROCEED TO SECONDARY MUSTER AREA LOCATED AT RP6N LER BUILDING TR FOR MUSTERING.

  1. LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING

EQUIPMENTS AND DIRECTIONAL ARROWS INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION.

  1. STAIRCASES SHOULD ALLOW TRANSPORTATION OF AN

INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.

  1. ALL FIRE & SAFETY EQUIPMENTS SHALL BE LOCATED IN SUCH

A WAY THAT THEY ARE EASILY ACCESSIBLE.

B

C

12.BREATHING AIR MANIFOLD FOR 6 PERSON, AS PER TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).

D

  1. ALL ESCAPE ROUTES SHALL BE MARKED WITH ESCAPE MARKER THAT IS VISIBLE, DURABLE AND ANTI-SLIP.

LEGEND:

LEGEND

DESCRIPTIONS

QTY

PRIMARY ESCAPE ROUTE 1.12m (WIDTH) X 2.286m (HEAD CLEARANCE) SECONDARY ESCAPE ROUTE 0.76m (WIDTH) X 2.286m (HEAD CLEARANCE) 135L AFFF FOAM WHEELED FIRE EXTINGUISHER

9 kg POTASSIUM BICARBONATE DRY CHEMICAL POWDER (BC) PORTABLE FIRE EXTINGUISHER

AFFF 135 L

9 Kg

LIFEBUOY WITH LIFELINE

BAM 6

BREATHING AIR MANIFOLD CABINET WITH 6 NUMBERS OF HOSE UNIT (NOTE 12)

1

2

4

1

HOLDS:

  1. TAG NOS.

KEY ELEVATION:

T.O.S.EL.33900

T.O.S.EL.26500

T.O.S.EL.15500

T.O.S.EL.10000 T.O.S. EL.6950

E

F

G

H

I

J

K

L

Project: Q-32705 - Saipem COMP3 Folder: RFQ Files


Loading authentication...

Graph View

Backlinks

  • 00 Index

Created with Infinity Constructor © 2025

  • Elynox | Go Further