1
45°
2
1
3
4
5
6
7
8
9
10
11
C
268-FEXXXX (HOLD-1)
kg
268-XZ8338 FB
268-XZ8350
D
268-XZXXXX (HOLD-1)
31900
268-XZ8343
268-FEXXXX (HOLD-1)
kg
12
LEGENDS:
LEGEND
kg
13
14
15
16
DESCRIPTIONS PRIMARY ESCAPE ROUTE 1.12m (WIDTH) X 2.286m (HEAD CLEARANCE) SECONDARY ESCAPE ROUTE 0.76m (WIDTH) X 2.286m (HEAD CLEARANCE) 4.5kg CO2 PORTABLE FIRE EXTINGUISHER
BREATHING AIR MANIFOLD CABINET WITH 10 NUMBERS OF HOSE UNIT (NOTE 7)
NOTES:
QTY
- ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS UNLESS STATED
OTHERWISE.
- PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT, SECONDARY
ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.).
- THIS LAYOUT SHALL BE USED ONLY FOR ESCAPE ROUTE, QUANTITY AND
A
LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENTS.
- THE PORTABLE EXTINGUISHERS LOCATED INDOOR SHALL BE PROVIDED
WITH WALL MOUNTING HANGER/ BRACKET.
5 1 5 3
BREATHING APPARATUS ESCAPE SET CABINET (15 MINUTES AND 3L CYLINDER)
STRETCHER
FB
FIRE BLANKET
FIRST AID KIT
1
2
0 0 0 1
72
ELECTRICAL SAFETY KIT
OXYGEN
FULL CYLINDER
OXYGEN CYLINDER WITH THE MASK
0 1 9 3 1
0 0 4
211
210
150
83
62 82
213
FB
75
74
72
202
204
203
206
207
205
201
1205
14
13
8 0 2
ELECTRICAL ROOM TOF EL. +16800
151
152
154
155
158
159
170
171
166
161
162
165
3
1000
72
0 5 2 1
0 0 2
1200
1000
173
41
10
172
168
169
12
0 0 2
6
7
8
52
174
60
59
164
105
106
101
0 0 2
0 0 2
TEMPORARY REFUGE AREA (0.6 SQM X 20 PP)
209
175
57
55
51
212
7 5 6
73
73
4000
9500
7200
7700
11 61 81
92
163
AIR LOCK
42
80
5
72
FB
75
74
70
0 0 2
OXYGEN
FULL CYLINDER
268-XZ8357
FB 268-XZ8339
268-XZ8351
4
2
1
2
2
2
1
1
- LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENTS AND
DIRECTIONAL ARROWS INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION.
- ALL FIRE & SAFETY EQUIPMENTS SHALL BE LOCATED IN SUCH A WAY
THAT THEY ARE EASILY ACCESSIBLE.
- BREATHING AIR MANIFOLD FOR 10 PERSON, AS PER TECHNICAL SAFETY
BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).
-
NOVEC 1230 (FK-5-1-12) CLEAN AGENT PROTECTION SHALL BE PROVIDED FOR ELECTRICAL & INSTRUMENT ROOM AND UPS ROOM IN THE LER.
-
OXYGEN CYLINDER WITH FACE MASK SHALL BE PROVIDED INSIDE
BUILDING (TEMPORARY REFUGE).
- FOR TEMPORARY REFUGE, AN OVERALL FREE FLOOR SPACE OF 12 M²
BETWEEN EQUIPMENTS SHALL BE MAINTAINED IN THE TR.
- AIR LOCK ROOM SHOULD ALLOW SAFE MANEUVERING OF AN INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.
HOLDS:
- TAG NOS.
KEY PLAN
A A A A
B B B B
C C C C
D D D D
GE TO GE TO GE TO GE TO N N N N RID RID RID RID P6 P6 P6 P6 WH WH WH WH B B B B
AM PLEMANN GANGWAY AM PLEMANN GANGWAY AM PLEMANN GANGWAY AM PLEMANN GANGWAY LANDING (NOTE 5) LANDING (NOTE 5) LANDING (NOTE 5) LANDING (NOTE 5)
UP UP UP UP
UP UP UP UP
TO TO TO TO TOP DECK TOP DECK TOP DECK TOP DECK
I I I I
N N N N A A A A R R R R D D D D
K K K K C C C C E E E E D D D D
05 05 05 05
O O O O T T T T
N N N N D D D D
PIPING PIPING PIPING PIPING AR EA AR EA AR EA AR EA
DROP ZON E DROP ZON E DROP ZON E DROP ZON E DRAIN DEC K DRAIN DEC K DRAIN DEC K DRAIN DEC K
MAIN DE CK MAIN DE CK MAIN DE CK MAIN DE CK LAYDOWN LAYDOWN LAYDOWN LAYDOWN AR EA AR EA AR EA AR EA
MAIN DE CK MAIN DE CK MAIN DE CK MAIN DE CK LAYDOWN LAYDOWN LAYDOWN LAYDOWN AR EA AR EA AR EA AR EA
PIPING AREA PIPING AREA PIPING AREA PIPING AREA
268MOV-50015 268MOV-50015 268MOV-50015 268MOV-50015
268 SDV-49002 268 SDV-49002 268 SDV-49002 268 SDV-49002
MONORAIL MONORAIL MONORAIL MONORAIL
MONOR AIL MONOR AIL MONOR AIL MONOR AIL
PIPING AR EA PIPING AR EA PIPING AR EA PIPING AR EA
14 14 14 14
MONOR AIL MONOR AIL MONOR AIL MONOR AIL
PI G HANDLIN G PI G HANDLIN G PI G HANDLIN G PI G HANDLIN G AR EA AR EA AR EA AR EA
03B 03B 03B 03B
268 MOV-5 00016 268 MOV-5 00016 268 MOV-5 00016 268 MOV-5 00016
268 MOV-5 00017 268 MOV-5 00017 268 MOV-5 00017 268 MOV-5 00017
PIPING PIPING PIPING PIPING AREA AREA AREA AREA
268MOV-50 014 268MOV-50 014 268MOV-50 014 268MOV-50 014 268MOV-50 019 268MOV-50 019 268MOV-50 019 268MOV-50 019
03A 03A 03A 03A
PIPING AREA PIPING AREA PIPING AREA PIPING AREA
268MOV-50020 268MOV-50020 268MOV-50020 268MOV-50020
PIPING AR EA PIPING AR EA PIPING AR EA PIPING AR EA
268 SDV-49009
MON ORAIL
MONOR AIL MONOR AIL MONOR AIL MONOR AIL 28 28 28 28
MON OR AIL MON OR AIL MON OR AIL MON OR AIL
21 21 21 21
LADDER TO LADDER TO LADDER TO LADDER TO LER ROOF LER ROOF LER ROOF LER ROOF
A A A A E E E E R R R R A A A A G G G G N N N N P P P P P P P P
I I I I
I I I I
24 24 24 24
P P P P A A A A R R R R T T T T
G G G G P P P P
I I I I
N N N N W W W W O O O O D D D D Y Y Y Y A A A A L L L L
A A A A E E E E R R R R A A A A
PI G HANDLIN G PI G HANDLIN G PI G HANDLIN G PI G HANDLIN G AR EA AR EA AR EA AR EA
MONOR AIL MONOR AIL MONOR AIL MONOR AIL
3 3 3 3
2 2 2 2
1 1 1 1
268-XZ8347 268-XZ8348
kg
268-FEXXXX (HOLD-1)
268-XZ8305
kg
268-FEXXXX (HOLD-1)
ELECTRICAL ROOM LER LEVEL - 1 AT MAIN DECK TOS. EL +15500
268-XZXXXX (HOLD-1)
SI. NO.
TAG
DESCRIPTION
DIMENSIONS (MM)
LENGTH WIDTH
HEIGHT
WEIGHT (KG)
TYPE OF MOUNTING
TELECOM EQUIPMENT LIST
26 26 26 26
19 19 19 19
20 20 20 20
27A 27A 27A 27A
27B 27B 27B 27B
A A A A E E E E R R R R A A A A G G G G N N N N P P P P P P P P
I I I I
I I I I
04A 04A 04A 04A
04B 04B 04B 04B
TO DRA IN DECK TO DRA IN DECK TO DRA IN DECK TO DRA IN DECK
P P P P U U U U
N N N N D D D D
P P P P U U U U
Y Y Y Y R R R R A A A A R R R R O O O O P P P P M M M M E E E E T T T T
E E E E G G G G U U U U F F F F E E E E R R R R
TO TOP DECK TO TOP DECK TO TOP DECK TO TOP DECK
THIS DRAWING
SI.NO.
TAG
DESCRIPTION
DIMENSIONS (MM)
LENGTH WIDTH
HEIGHT
WEIGHT (KG)
TYPE OF MOUNTING
SI. NO.
TAG
DESCRIPTION
DIMENSIONS (MM)
LENGTH WIDTH
HEIGHT
WEIGHT (KG)
TYPE OF MOUNTING
150 HOLD-1
DCS CONSOLE (OWS / EWS / AUX)
3000
INSTRUMENT EQUIPMENT LIST
ELECTRICAL EQUIPMENT LIST
1
2
3
5
6
7
8
HOLD-1
HOLD-1
HOLD-1
HOLD-1
HOLD-1
HOLD-1
HOLD-1
11kV SWITCHBOARD
11/0.4kV TRANSFORMER
LV NORMAL SWITCHBOARD
MAIN LIGHTING & SMALL POWER DB
LIGHTING & SMALL POWER DB
POWER DISTRIBUTION BOARD
LIGHTING DISTRIBUTION BOARD
10
HOLD-1
SUBSEA CABLE MONITORING CABINET
11
HOLD-1
PARTIAL DISCHARGE ACQUISITION
12
13
14
KEY ONE LINE DIAGRAM FRAME
BREAKER TROLLEY (MV)
BREAKER TROLLEY (LV)
41 HOLD-1
IMCS CABINET
42
57
KEY BOX
HOLD-1
SAFETY LAMP & SELF-CONTEINED CHARGING UNIT
208 HOLD-1
TELECOM PDB
4100
1800
7400
1400
800
800
800
800
600
1000
1000
1000
800
300
500
1400
1750
1300
1600
600
400
400
400
800
210
50
800
800
800
150
600
400
2750
1900
2400
1400
1600
1600
1600
2000
600
700
900
900
6600
FLOOR MOUNTED
2500
FLOOR MOUNTED
8500
FLOOR MOUNTED
300
150
150
150
300
50
10
80
80
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
FLOOR MOUNTED
WALL MOUNTED
WALL MOUNTED
PORTABLE
PORTABLE
2100
450
FLOOR MOUNTED
350
500
30
WALL MOUNTED
WALL MOUNTED
2100
200
FLOOR MOUNTED
SI. NO.
TAG
DESCRIPTION
DIMENSIONS (MM)
LENGTH WIDTH
HEIGHT
WEIGHT (KG)
TYPE OF MOUNTING
151 HOLD-1
DCS MARSHALLING CABINET - 1
152 HOLD-1
DCS SYSTEM CABINET-1
153 HOLD-1
DCS MARSHALLING CABINET - 3
154 HOLD-1
DCS SYSTEM CABINET - 2
155 HOLD-1
DCS MARSHALLING CABINET - 2
156 HOLD-1
F&G MARSHALLING CABINET - 3
157 HOLD-1
F&G SYSTEM CABINET - 2
158 HOLD-1
ESD MARSHALLING CABINET - 1
159 HOLD-1
ESD SYSTEM CABINET
160 HOLD-1
ESD MARSHALLING CABINET - 2
161 HOLD-1
F&G MARSHALLING CABINET - 1
162 HOLD-1
F&G SYSTEM CABINET - 1
163 HOLD-1
HSSD PANEL - 1
164 HOLD-1
HSSD PANEL - 2
165 HOLD-1
F&G MARSHALLING CABINET - 2
166 HOLD-1
HIPPS CABINET
168 HOLD-1
NETWORK CABINET
169 HOLD-1
ICSS SERVER CABINET
HVAC / ARCHITECTURAL EQUIPMENT LIST
170 HOLD-1
ICSS PDP
101 HOLD-1
HVAC CONTROL PANEL
102 HOLD-1
HVAC PURGE PANEL FOR ELECTRICAL ROOM - LER 1ST FLOOR
105
FILING CABINET
106 HOLD-1
DUCT HEATER PANEL
1800
600
800
800
800
500
500
500
2100
1000
1200
2100
600
200
100
600
FLOOR MOUNTED
171 HOLD-1
IRP CABINET
WALL MOUNTED
172 HOLD-1
FUTURE CABINET
FLOOR MOUNTED
173 HOLD-1
FUTURE CABINET
FLOOR MOUNTED
174 HOLD-1
DCS CONSOLE (OWS)
175 HOLD-1
MULTI-GAS DETECTOR
800
800
800
800
800
800
800
800
800
800
800
800
800
300
300
800
800
1000
1000
800
800
800
800
800
482
770
2100
2100
2100
2100
2100
2100
2100
2100
2100
2100
2100
2100
600
600
2100
2100
2100
2100
2100
2100
2100
2100
770
640
800
800
800
800
800
800
800
800
800
800
800
800
600
600
800
800
800
800
800
800
800
800
1000
457
300
450
450
450
450
450
450
450
450
450
450
450
450
150
150
450
450
450
450
450
450
201 HOLD-1
TELECOM CABINET -1
202 HOLD-1
TELECOM CABINET -2
203 HOLD-1
TELECOM CABINET -3
204 HOLD-1
TELECOM CABINET -4
FLOOR MOUNTED
205 HOLD-1
PROCESS CCTV CABINET
FLOOR MOUNTED
206 HOLD-1
PA/GA SYSTEM CABINET A
FLOOR MOUNTED
207 HOLD-1
PA/GA SYSTEM CABINET B
FLOOR MOUNTED
209 HOLD-1
TELECOM CONSOLE-1
FLOOR MOUNTED
210 HOLD-1
TELECOM CONSOLE-2
FLOOR MOUNTED
211 HOLD-1
TELEPHONE WALL OUTLET
FLOOR MOUNTED
212 HOLD-1
ACS ENCLOSURE
FLOOR MOUNTED
213 HOLD-1
ACS ENCLOSURE
FLOOR MOUNTED
51 HOLD-1
BREATHING AIR MANIFOLD A
FLOOR MOUNTED
52 HOLD-1
BREATHING AIR MANIFOLD B
FLOOR MOUNTED
55 HOLD-1
ESCAPE BREATHING APPARATUS
FLOOR MOUNTED
59 HOLD-1
NOVEC MAIN JB
WALL MOUNTED
60 HOLD-1
NOVEC CONTROL PANEL
WALL MOUNTED
61 HOLD-1
NOVEC LOCAL STATUS PANEL 1
FLOOR MOUNTED
62 HOLD-1
NOVEC LOCAL STATUS PANEL 2
FLOOR MOUNTED
LOSPE EQUIPMENT LIST
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
200
FLOOR MOUNTED
8
FLOOR MOUNTED
70 HOLD-1
OXYGEN CYLINDER WITH MASK
72 HOLD-1
4.5 KG CO2 EXTINGUISHER (4 NO.)
178 DIA
73 HOLD-1
STRETCHER (2 NO.)
74 HOLD-1
FIRST AID KIT (2 NO.)
75 HOLD-1
FIRE BLANKET (2 NO.)
80 HOLD-1
NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL
81 HOLD-1
NOVEC INDOOR PUSH BUTTON & LAMP PANEL
82 HOLD-1
NOVEC INDOOR PUSH BUTTON & LAMP PANEL
83 HOLD-1
NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL
92 HOLD-1
ELECTRICAL SAFETY KIT
95 HOLD-1
LIFE JACKET CABINET
300
448
300
450
450
450
450
1000
1600
800
800
800
800
800
800
800
800
1900
100
616
616
1700
1700
750
800
600
300
300
300
800
1000
800
800
800
800
800
600
600
250
300
300
610
610
600
400
400
150
150
300
500
213
500
300
300
300
300
400
600
2100
2100
2100
2100
1500
2100
2100
1690
1690
200
616
616
960
960
857
1500
1200
300
300
1000
1225
1200
425
1200
450
450
450
450
1800
1750
13
400
400
400
400
250
250
250
450
450
80
80
150
150
224
120
120
15
15
20
23
10
15
10
40
40
40
40
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
WALL MOUNTED
PORTABLE
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
200-20-SH-DEC-00013
TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT
268-91-EL-PLN-00001-0004
ELECTRICAL EQUIPMENT LAYOUT LOCAL EQUIPMENT ROOM (LER) FOR RPN6
268-23-PI-PLP-00003
EQUIPMENT ARRANGEMENT PLAN MAIN DECK FOR RP6N
REFERENCE NO.
TITLE
REFERENCES
A
A1
NO.
ISSUED FOR REVIEW
ISSUED FOR IDC
DESCRIPTION
PROJECT TITLE :
REVISIONS
Digita lly signe d by Valentina Brusati DN: cn=Valentina Brusati, o=Saipem, ou, email=valentina. brusa ti@saipem. co m, c=IT Date: 2025. 04. 15 13 :4 1:48 +02’ 00’
Gabri ella Alma sio
al ma sio @ sai pem.c om Re ason: I have re vie wed
VB
VB
BY
GA
GA
BPB
BPB
15/04/25
09/04/25
CHKD
APVD
DATE
NFPS Offshore Riser Platforms & Intrafield Pipelines Project - COMP3
Qatar Energy LNG
Qatar Ene rgy LNG
THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.
CONSULTANT / CONTRACTOR :
Saipem S.p.A.
CONTRACTOR DRAWING NO:
033764-L-D00-18-SPM-LP-D-00046-0001
TITLE :
FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - LOCAL EQUIPMENT ROOM - RP6N
145
100
FLOOR MOUNTED
FLOOR MOUNTED
SCALE :
1:75
PROJECT NO. :
033764
PROJECT
033764
DRAWING NO.
SHT
SIZE REVISION
268-83-SH-PLN-00003
0001
A1
A
14
15
16
1
2
3
4
5
6
7
10
11
12
B
C
D
E
F
G
H
I
J
K
L
A
B
C
D
E
F
G
H
I
J
K
L
Classification: Internal
1
45°
A
B
C
D
E
F
G
H
I
J
K
L
2
3
4
5
6
7
8
9
10
11
12
13
14
NOTES:
15
16
268-EW8301
EYE WASH
C
268-FEXXXX (HOLD-1)
268-FEXXXX (HOLD-1)
kg
kg
268-XZ8344
D
268-XZ8340 FB
3600
3900
9500
2320
268-XZ8352
7200
0 1 9 3 1
103
72
87
1500
20
21
22
31
40
23
30
36
29
28
35
72
38
37
15
16
25
17
18
26
24
167
27
19
34
32
33
39
93
FB
FB
74
75
104
85
200
4 1 2
AIR LOCK
84
63 72
EQUIPMENT LIST FOR BATTERY ROOM (LER 2ND FLOOR)
EQUIPMENT LIST FOR UPS ROOM (LER 2ND FLOOR)
SI.NO.
TAG
DESCRIPTION
DIMENSIONS (MM)
LENGTH WIDTH
HEIGHT
WEIGHT (KG)
TYPE OF MOUNTING
SI.NO.
TAG
DESCRIPTION
DIMENSIONS (MM)
LENGTH WIDTH
HEIGHT
WEIGHT (KG)
TYPE OF MOUNTING
ELECTRICAL EQUIPMENT LIST
ELECTRICAL EQUIPMENT LIST
UPS ROOM / BATTERY ROOM LER LEVEL-2 TOS. EL +20900
kg
268-FEXXXX (HOLD-1)
20 HOLD-1
AC UPS A MCCB BOX
21 HOLD-1
AC UPS B MCCB BOX
22 HOLD-1
AC UPS A BATTERY BANK
23 HOLD-1
AC UPS B BATTERY BANK
28 HOLD-1
DC UPS A MCCB BOX
29 HOLD-1
DC UPS B MCCB BOX
30 HOLD-1
DC UPS A BATTERY BANK
31 HOLD-1
DC UPS B BATTERY BANK
35 HOLD-1
NAV - AID UPS ISOLATION SWITCH (Ex’de”)
36 HOLD-1
NAV - AID UPS BATTERY BANK
40 HOLD-1
BATTERY LIFTING TROLLEY
500
500
3920
3920
500
500
1700
1700
500
1500
1050
300
300
800
800
300
300
800
800
300
900
650
600
600
1540
1540
600
600
1400
1400
600
1130
1600
HVAC EQUIPMENT LIST
100
100
WALL MOUNTED
WALL MOUNTED
2500
FLOOR MOUNTED
2500
FLOOR MOUNTED
WALL MOUNTED
100
100
1220
FLOOR MOUNTED
100
PORTABLE
103 HOLD-1
HVAC PURGE PANEL FOR BATTERY ROOM - LER 2ND FLOOR
600
500
1000
200
WALL MOUNTED
72 HOLD-1
6.8KG CO2 EXTINGUISHER
87 HOLD-1
PORTABLE EYE WASH
178 DIA
300
250
1225
300
7
10
WALL MOUNTED
WALL MOUNTED
LOSPE EQUIPMENT LIST
15
16
17
18
19
HOLD-1
HOLD-1
HOLD-1
HOLD-1
HOLD-1
AC UPS SYSTEM A
AC UPS SYSTEM B
AC UPS DISTRIBUTION BOARD A
AC UPS DISTRIBUTION BOARD B
AC UPS BATTERY MONITORING SYSTEM
WALL MOUNTED
24 HOLD-1
DC UPS BATTERY CHARGER
1100
FLOOR MOUNTED
25
HOLD-1
DC UPS DISTRIBUTION BOARD A
1100
FLOOR MOUNTED
26 HOLD-1
DC UPS DISTRIBUTION BOARD B
100
WALL MOUNTED
27 HOLD-1
DC UPS BATTERY MONITORING SYSTEM
32
33
34
37
38
39
HOLD-1
HOLD-1
HOLD-1
HOLD-1
HOLD-1
HOLD-1
NAVIGATIONAL AIDS UPS A
NAVIGATIONAL AIDS UPS B
MAIN DISTRIBUTION BOARD NAV - AID UPS
LIGHTING & SMALL POWER DB
POWER DISTRIBUTION BOARD
HELIDECK LIGHTING MAIN CONTROL PANEL
3000
3000
1600
1600
600
2940
1200
1200
600
1200
1200
800
1000
1000
800
1000
1000
800
800
400
1000
800
800
400
800
800
800
400
400
800
2200
2200
2000
2000
1000
2200
2000
2000
1000
2200
2200
2450
1600
1600
1000
3500
FLOOR MOUNTED
3500
FLOOR MOUNTED
500
500
100
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
2000
FLOOR MOUNTED
500
500
100
500
500
100
200
200
160
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
FLOOR MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
HVAC EQUIPMENT LIST
104 HOLD-1
HVAC PURGE PANEL FOR UPS ROOM - LER 2ND FLOOR
600
500
1000
200
WALL MOUNTED
LOSPE EQUIPMENT LIST
63
72
74
HOLD-1
HOLD-1
HOLD-1
NOVEC LOCAL STATUS PANEL 3
6.8KG CO2 EXTINGUISHER (3 NO.)
FIRST AID KIT
75
HOLD-1
FIRE BLANKET
84
85
93
HOLD-1
HOLD-1
HOLD-1
NOVEC INDOOR PUSH BUTTON & LAMP PANEL
NOVEC OUTDOOR PUSH BUTTON & LAMP PANEL
ELECTRICAL SAFETY KIT
300
178 DIA
448
300
450
450
1000
150
213
500
300
300
400
300
1225
425
1200
450
450
15
7
15
10
40
40
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
1800
145
FLOOR MOUNTED
INSTRUMENT EQUIPMENT LIST
167 HOLD-1
HSSD PANEL - 3
600
300
600
150
WALL MOUNTED
214 HOLD-1
ACS ENCLOSURE
616
300
616
80
WALL MOUNTED
TELECOM EQUIPMENT LIST
- ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS UNLESS STATED
OTHERWISE.
- PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT, SECONDARY
ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.).
- THIS LAYOUT SHALL BE USED ONLY FOR ESCAPE ROUTE, QUANTITY AND
LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENTS.
- THE PORTABLE EXTINGUISHERS LOCATED INDOOR SHALL BE PROVIDED
A
WITH WALL MOUNTING HANGER/ BRACKET.
- LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENTS AND
DIRECTIONAL ARROWS INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION.
- ALL FIRE & SAFETY EQUIPMENTS SHALL BE LOCATED IN SUCH A WAY
THAT THEY ARE EASILY ACCESSIBLE.
- BREATHING AIR MANIFOLD FOR 10 PERSON, AS PER TECHNICAL SAFETY
BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).
- NOVEC 1230 (FK-5-1-12) CLEAN AGENT PROTECTION SHALL BE PROVIDED FOR ELECTRICAL & INSTRUMENT ROOM AND UPS ROOM IN THE LER.
B
- OXYGEN CYLINDER WITH FACE MASK SHALL BE PROVIDED INSIDE
BUILDING (TEMPORARY REFUGE).
- FOR TEMPORARY REFUGE, AN OVERALL FREE FLOOR SPACE OF 12 M²
BETWEEN EQUIPMENTS SHALL BE MAINTAINED IN THE TR.
- AIR LOCK ROOM SHOULD ALLOW SAFE MANEUVERING OF AN INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.
LEGENDS:
LEGEND
kg
FB
DESCRIPTIONS PRIMARY ESCAPE ROUTE 1.12m (WIDTH) X 2.286m (HEAD CLEARANCE) SECONDARY ESCAPE ROUTE 0.76m (WIDTH) X 2.286m (HEAD CLEARANCE) 4.5kg CO2 PORTABLE FIRE EXTINGUISHER
FIRE BLANKET
FIRST AID KIT
EYE WASH
PORTABLE EYE WASH
ELECTRICAL SAFETY KIT
QTY
3
1
1
1
1
HOLDS:
- TAG NOS.
KEY PLAN
A A A A
B B B B
C C C C
D D D D
RIDGE TO RIDGE TO RIDGE TO RIDGE TO
P6N P6N P6N P6N WH WH WH WH
B B B B
AMPLEMA NN GANGWAY AMPLEMA NN GANGWAY AMPLEMA NN GANGWAY AMPLEMA NN GANGWAY LA NDING (NOTE 5) LA NDING (NOTE 5) LA NDING (NOTE 5) LA NDING (NOTE 5)
UP UP UP UP
UP UP UP UP
TO TO TO TO TO P DECK TO P DECK TO P DECK TO P DECK
I I I I
N N N N A A A A R R R R D D D D
K K K K C C C C E E E E D D D D
05 05 05 05
PIPING PIPING PIPING PIPING AR EA AR EA AR EA AR EA
O O O O T T T T
N N N N D D D D
DROP Z ONE DROP Z ONE DROP Z ONE DROP Z ONE DRAIN DECK DRAIN DECK DRAIN DECK DRAIN DECK
MAIN DECK MAIN DECK MAIN DECK MAIN DECK L AYDOWN L AYDOWN L AYDOWN L AYDOWN AR EA AR EA AR EA AR EA
MAIN DECK MAIN DECK MAIN DECK MAIN DECK L AYDOWN L AYDOWN L AYDOWN L AYDOWN AR EA AR EA AR EA AR EA
PIPING AREA PIPING AREA PIPING AREA PIPING AREA
3 3 3 3
2 2 2 2
1 1 1 1
2 68MOV-50015 2 68MOV-50015 2 68MOV-50015 2 68MOV-50015
268SDV-49 002 268SDV-49 002 268SDV-49 002 268SDV-49 002
MONORAIL MONORAIL MONORAIL MONORAIL
MONORAIL MONORAIL MONORAIL MONORAIL
PIPING AREA PIPING AREA PIPING AREA PIPING AREA
14 14 14 14
MONOR AIL MONOR AIL MONOR AIL MONOR AIL
PIG HAND LIN G PIG HAND LIN G PIG HAND LIN G PIG HAND LIN G AR EA AR EA AR EA AR EA
A A A A E E E E R R R R A A A A G G G G N N N N P P P P P P P P
I I I I
I I I I
24 24 24 24
P P P P A A A A R R R R T T T T G G G G P P P P
N N N N W W W W O O O O D D D D Y Y Y Y A A A A L L L L
I I I I
A A A A E E E E R R R R A A A A
PIG HAND LIN G PIG HAND LIN G PIG HAND LIN G PIG HAND LIN G AR EA AR EA AR EA AR EA
MON ORAIL MON ORAIL MON ORAIL MON ORAIL
03B 03B 03B 03B
268M OV -5 00016 268M OV -5 00016 268M OV -5 00016 268M OV -5 00016
268M OV -500017 268M OV -500017 268M OV -500017 268M OV -500017
PIPING PIPING PIPING PIPING AREA AREA AREA AREA
268M OV-50014 268M OV-50014 268M OV-50014 268M OV-50014 268M OV-50019 268M OV-50019 268M OV-50019 268M OV-50019
03A 03A 03A 03A
PIPING AREA PIPING AREA PIPING AREA PIPING AREA
2 68MOV-50020 2 68MOV-50020 2 68MOV-50020 2 68MOV-50020
PIPIN G AREA PIPIN G AREA PIPIN G AREA PIPIN G AREA
268SDV-49009
MONORAIL
MONORAIL MONORAIL MONORAIL MONORAIL 28 28 28 28
MON ORAIL MON ORAIL MON ORAIL MON ORAIL
21 21 21 21
LADDER TO LADDER TO LADDER TO LADDER TO LER ROOF LER ROOF LER ROOF LER ROOF
26 26 26 26
19 19 19 19
20 20 20 20
27A 27A 27A 27A
27B 27B 27B 27B
A A A A E E E E R R R R A A A A G G G G N N N N P P P P P P P P
I I I I
I I I I
04A 04A 04A 04A
04B 04B 04B 04B
T O DRAIN DEC K T O DRAIN DEC K T O DRAIN DEC K T O DRAIN DEC K
P P P P U U U U
N N N N D D D D
P P P P U U U U
Y Y Y Y R R R R A A A A R R R R O O O O P P P P M M M M E E E E T T T T
E E E E G G G G U U U U F F F F E E E E R R R R
T O TOP DECK T O TOP DECK T O TOP DECK T O TOP DECK
THIS DRAWING
200-20-SH-DEC-00013
TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT
268-91-EL-PLN-00001-0005
ELECTRICAL EQUIPMENT LAYOUT LOCAL EQUIPMENT ROOM (LER) FOR RPN6
268-23-PI-PLP-00003
EQUIPMENT ARRANGEMENT PLAN MAIN DECK FOR RP6N
REFERENCE NO.
TITLE
REFERENCES
ISSUED FOR REVIEW
Gabriell a Digit ally signed by Vale ntina Brusat i Alm asi DN: cn=Valent ina Brusa ti, o o=Saipe m, ou, e mail=valentin a.bru sati@saipem.c om, c=IT Date : 2025.04. 15 13:42:34 +02’00’
gab rie lla.alm asi o@ sai pem.com Re ason: I have re vie wed this docu ment
VB
GA
ISSUED FOR IDC
VB
GA
BPB
BPB
15/04/25
08/04/25
DESCRIPTION
BY
CHKD
APVD
DATE
REVISIONS
A
A1
NO.
PROJECT TITLE :
NFPS Offshore Riser Platforms & Intrafield Pipelines Project - COMP3
Qatar Energy LNG
Qatar Ene rgy LNG
THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.
CONSULTANT / CONTRACTOR :
Saipem S.p.A.
CONTRACTOR DRAWING NO:
033764-L-D00-18-SPM-LP-D-00046-0002
TITLE :
FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - LOCAL EQUIPMENT ROOM - RP6N
SCALE :
1:75
PROJECT NO. :
033764
PROJECT
033764
DRAWING NO.
SHT
SIZE REVISION
268-83-SH-PLN-00003
0002
A1
A
C
D
E
F
G
H
I
J
K
L
1
2
3
4
5
6
7
10
11
12
13
14
15
16
Project: Q-32705 - Saipem COMP3 Folder: RFQ Files