PLATFORM NORTH

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

LEGEND:

NOTES:

N

TRUE NORTH

TRUE NORTH

PREVAILING WIND

45°

A

B

C

D

15000

15000

9500

7200

268-XZ8317

7500

2400

NAVAID MAIN LANTERN

AMPLEMANN GANGWAY

FROM TOP DECK

SWING ROPES

XXX-FEXXXX (HOLD-1)

9 Kg

DROPE ZONE CELLAR DECK

FUTURE LAYDOWN AREA

FROM CELLAR DECK

PIG RECEIVER FOR PL13N (TEMPORARY)

BRIDGE TO HP6N

W

FOG HORN

268-T8702

LAYDOWN AREA

268-XP9601C

268-XP9601F

268-XP9601B

268-XP9601G

T.O.S. 15500

268-V9501

268-XP9601D

268-XP9601H

FROM CELLAR DECK

268-XP9601A

268-XP9601E

268-XP9601L

LEGEND

CO2 4.5 kg

9 Kg

BC 56.7 kg

n=4

FE

SC

BAM 6

n=10

WV

DESCRIPTIONS PRIMARY ESCAPE ROUTE 1.12m (WIDTH) X 2.286m (HEAD CLEARANCE) SECONDARY ESCAPE ROUTE 0.76m (WIDTH) X 2.286m (HEAD CLEARANCE) 4.5 kg CO2 PORTABLE FIRE EXTINGUISHER 9 kg POTASSIUM BICARBONATE DRY CHEMICAL POWDER (BC) PORTABLE FIRE EXTINGUISHER

56.7kg DRY CHEMICAL POWDER (BC) WHEELED FIRE EXTINGUISHER

LIFEBUOY WITH LIFELINE

LIFE RAFT n=(NUMBERS OF PERSON CAPACITY)

SELF CONTAINED BREATHING APPARATUS (45 MINUTES) (NOTE 13) CABINET FOR 4 UNITS OF SCBA

FIREMAN EQUIPMENT CABINET

SCRAMBLE NET

BREATHING AIR MANIFOLD CABINET WITH 6 NUMBERS OF HOSE UNITS (NOTE 12)

LIFE JACKET

CABINET FOR 10 UNITS OF LIFE JACKET

WORK VEST CABINET WITH 20 UNITS OF WORK VEST

NOVEC

NOVEC 1230 (FK-5-1-12) FIRE SUPPRESSION SYSTEM PACKAGE (NOTE 14)

QTY

3

5

2

4

2

4

1

1

1

2

20

2

1

1

BRIDGE LENGHT 73M

NG268230031-34” PRODUCTION FROM WHP6N

NG268007-32” PRODUCTION TO WHP6N

XXX-FEXXXX (HOLD-1)

9 Kg

268-XZ8318

NAVIGATION AID

XXX-FEXXXX (HOLD-1)

9 Kg

0 0 0 5

0 0 5 7

3

XXX-XZXXXX (HOLD-1)

BAM 6

2

XXX-FEXXXX (HOLD-1)

9 Kg

0 0 5 1

0 0 5 3

0 5 2 2

0 0 2 3

0 0 0 4 1

0 0 1 3

XXX-FEXXXX (HOLD-1)

BC 56.7 kg

1

268-XZ8320

0 0 2 3

0 5 2 2

0 0 7 2

0 0 5 8

NAVIGATION AID

GPS ANTENNA

FOG DETECTOR

268MOV-230015

268SDV-230002

268MOV-230016

268MOV-230017

268MOV-230019

268MOV-230014

B 1 0 3 2 Y

8 6 2

268MOV-230020

COAMED AREA

HPU ACCUMUL. SKID

268-Y2301A

MR-MD-02 CAP 20MT MONORAIL

PIG RECEIVER FOR INTRAFIELD PIPELINE PL5N (TEMPORARY)

268SDV-230009

COAMED AREA

MONORAIL MR-MD-04 CAP 8MT

FROM CELLAR DECK

FIRE/BLAST WALL

PIG HANDLING

AREA

268-X HOLD

MR-MD-01 CAP 20MT MONORAIL

Y R A R O P M E T

R O T A R E N E G

L E S E D

I

LAYDOWN AREA

BC 56.7 kg

XXX-FEXXXX (HOLD-1)

XXX-XZXXXX (HOLD-1) BAM 6

MONORAIL MR-MD-08 CAP 4MT

LAYDOWN AREA

PIG HANDLING AREA

268-X HOLD

T.O.G.+16800

268-XZ8302

268-XZ9501A

268-XZ9501B

FROM TOP DECK

XXX-FEXXXX (HOLD-1)

9 Kg

0 0 5 3

5 1 5 3

0 1 4 3 1

268-XZ8305

n=4

268-XZ8319

268-XZ8330

268-XZ8304

SC

268-XZ8334

268-XZ8329

268-XZ8303

MONORAIL MR-MD-05 CAP 8MT

WV

268-XZ8332

I

E G D R B E R U T U F

6 P C O T

MONORAIL MR-MD-03 CAP 8MT

FUTURE TEST SEPARATOR

268-V2301

0 9 2 3

FIRE/BLAST WALL

INSTRUMENT & ELECTRICAL ROOM (NOTE 15)

TEMPORARY

REFUGE

AIR LOCK

4000

LAYDOWN AREA

NAVIGATION AID

GPS ANTENNA

14900

NOVEC 268-XZ8302

FE 268-XZ8356

7700

1800

CO2 4.5 kg

XXX-FEXXXX XXX-FEXXXX XXX-FEXXXX (HOLD-1) (NOTE 16)

EQUIPMENT NO.

268-T8702

CP SEPARATOR

EQUIPMENT LIST

DESCRIPTION

268-XP9601A/B/C/D/E/F/G/H/L

N2 CYLINDER RACK

268-V9501

268-XZ8334

268-X8303

268-X8304

268-XZ8329

268-XZ8330

268-XZ9501A/B

268-Y2301A

268-Y2301B

268-HOLD

268-HOLD

268-HOLD

268-HOLD

268-V2301

MR-MD-01

MR-MD-02

MR-MD-03

MR-MD-04

MR-MD-05

MR-MD-08

268-XZ8302

HOLD

INST.AIR RECEIVER SCRAMBLE NET

LIFERAFT

LIFERAFT

LIFE JACKET CABINET

LIFE JACKET CABINET

BREATING AIR CYLINDER RACK

TOPSIDE HYDRAULIC POWER UNIT (HPU)

SUB-SEA HYDRAULIC POWER UNIT (HPU)

HPU ACCUMULATOR SKID

NAV AID LIGHTS

PIG RECEIVER FOR INTRAFIELD PIPELINE PL5N (TEMPORARY)

PIG RECEIVER FOR INTRAFIELD PIPELINE PL13N (TEMPORARY)

TEST SEPARATOR (FUTURE) ELE. TROLLEY HOIST FOR MONORAIL BEAM (PERM.)

ELE. TROLLEY HOIST FOR MONORAIL BEAM (PERM.)

MANUAL TROLLEY HOIST FOR 6 MONORAIL BEAMS (REMOV.)

MANUAL TROLLEY HOIST FOR 6 MONORAIL BEAMS (REMOV.)

MANUAL TROLLEY HOIST FOR 6 MONORAIL BEAMS (REMOV.)

MANUAL TROLLEY HOIST FOR 6 MONORAIL BEAMS (REMOV.)

CLEAN AGENT PACKAGE

TEMPORARY DIESEL GENERATOR

1

2

3

(HOLD)

4

4400

3100

7500

7500

7500

MAIN DECK (T.O.S EL. +15500)

SIZE (MM)

3000(L) x 3000(W) x 1700(H)

1140(L) x 1140(W) x 2140(H)

1400(ID) x 4000(T/T)

3000(L) x 600(W) x 500(H)

1308(W) x 713(Ø)

1308(W) x 713(Ø)

600(L) x 800(W) x 1750(H)

600(L) x 800(W) x 1750(H)

1380(L) x 1355(W) x 2500(H)

3000(L) x 2200(W) x 2500(H)

5000(L) x 2100(W) x 3200(H)

2000(L) x 2200(W) x 2500(H)

(HOLD)

(28”x32”) Dia x 7.438Mtr.

(28”x32”) Dia x 7.438Mtr.

ID 2000/5800 (H)

CAP. 20MT

CAP. 20MT

CAP. 8MT

CAP. 8MT

CAP. 8MT

CAP. 4MT

3000(L) x 1500(W) x 3200(H)

C

D

1

FIRE/BLAST WALL

T.O.S.+21900

UPS ROOM

T.O.S.+21900

MONORAIL MR-MD-07 CAP 3MT

HVAC AREA

T.O.S.+20900

A 1 0 U H A 1 0 2 4 H Y

8 6 2

B 1 0 U H A 1 0 2 4 H Y

8 6 2

AIR LOCK

TO LER LEVEL1

FIRE/BLAST WALL

BATTERY ROOM

DROP ZONE

MONORAIL MR-MD-06 CAP 3MT

PROJECT TITLE :

COMP3 - NFPS OFFSHORE RISER / WELLHEAD PLATFORM & INTRAFIELD PIPELINES PROJECT

Qatar Energy LNG

Qatar Ene rgy LNG

THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.

CONSULTANT / CONTRACTOR :

Saipem S.p.A.

100

200

100

200

TITLE :

400

400

CONTRACTOR DRAWING No. :

033764-L-D00-12-SPM-LP-D-00043-0001

FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - MAIN DECK - FOR RP6N

UPS ROOM / BATTERY ROOM LER LEVEL-2 (SCALE NTS)

TYPICAL DETAIL-1

TYPICAL DETAIL-2

N.T.S

N.T.S

SCALE :

1:150

PROJECT No. :

LTC/C/NFP/5129/20

PROJECT

033764

DRAWING No.

SHT

SIZE REVISION

268-83-SH-PLN-00004

0001

A1

A

5

6

7

10

11

12

13

14

15

16

  1. ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS

UNLESS STATED OTHERWISE.

  1. PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT,

SECONDARY ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.).

A

  1. THE MINIMUM HEADROOM HEIGHT SHALL BE PROVIDED IN ALL AREAS, MEASURED VERTICALLY FROM DECK SURFACE OF LANDING OR PLATFORM.

  2. THIS LAYOUT SHALL BE USED ONLY FOR ESCAPE ROUTE, QUANTITY AND LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENTS.

  3. AS PER TECHNICAL SAFETY BASIS OF DESIGN

(200-20-SH-DEC-00013), FOR OUTDOOR AREAS, THE DEAD END SHALL NOT EXCEED 6 M OF TRAVEL DISTANCE.

  1. THE PORTABLE EXTINGUISHERS LOCATED OUTDOOR SHALL

BE PROVIDED WITH WEATHER-PROOF CABINET.

  1. WHEELED EXTINGUISHERS LOCATED OUTDOOR SHALL BE

PROVIDED WITH A UV-RESISTANT RED-VINYL COVER.

  1. ARROWS SHOWN ON THE ESCAPE ROUTE DRAWING INDICATE ON THE PREFERRED DIRECTION OF EGRESS TOWARDS THE MUSTER AREA. IN CASE OF EMERGENCY AT RP6N, PERSONNEL SHALL USE BRIDGE TO REACH PRIMARY MUSTER AREA LOCATED AT WELLHEAD PLATFORM LER BUILDING TR. IN CASE ESCAPE THROUGH BRIDGE TOWARDS WELLHEAD IS NOT FEASIBLE, PERSONNEL TO PROCEED TO SECONDARY MUSTER AREA LOCATED AT RP6N LER BUILDING TR FOR MUSTERING.

  2. LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING

EQUIPMENTS AND DIRECTIONAL ARROWS ARE INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION.

  1. STAIRCASES SHOULD ALLOW TRANSPORTATION OF AN

INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.

  1. ALL FIRE & SAFETY EQUIPMENTS SHALL BE LOCATED IN SUCH

A WAY THAT THEY ARE EASILY ACCESSIBLE.

12.BREATHING AIR MANIFOLD FOR 6 PERSONS, AS PER

TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).

  1. AS PER TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE)

FOR COMP3 PROJECT (200-20-SH-DEC-00013), DEDICATED 45 MINUTES 4 SCBA SETS WITH CABINET SHOULD BE PROVIDED FOR INVESTIGATION TEAM USE ONLY.

14.NOVEC 1230 (FK-5-1-12) CLEAN AGENT PROTECTION SHALL BE PROVIDED FOR ELECTRICAL & INSTRUMENT ROOM AND UPS ROOM IN THE LER.

15.REFER TO FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE

B

C

D

LAYOUT - RP6N - LOCAL EQUIPMENT ROOM LAYOUT (268-83-SH-PLN-00003) FOR THE DETAIL ARRANGEMENT OF FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT INSIDE THE LER.

E

  1. THREE (3) NOS. CO2 PORTABLE FIRE EXTINGUISHERS SHALL BE LOCATED AT THE MAIN ENTRANCE TO THE ELECTRICAL & INSTRUMENT ROOM FOR FIRE BRIGADE USE.

HOLDS:

  1. TAG NOS.

KEY ELEVATION:

T.O.S.EL.34000

T.O.S.EL.26500

T.O.S.EL.15500

T.O.S.EL.10000 T.O.S. EL.6950

200-20-SH-DEC-00013

268-83-SH-PLN-00003

268-23-PI-PLP-00006

TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - LOCAL EQUIPMENT ROOM - RP6N EQUIPMENT ARRANGEMENT PLAN LER LEVEL 2 FOR RP6N

268-23-PI-PLP-00003

EQUIPMENT ARRANGEMENT PLAN MAIN DECK FOR RP6N

REFERENCE No. REFERENCE No.

TITLE TITLE

REFERENCES REFERENCES

A

A1

No.

ISSUED FOR REVIEW

ISSUED FOR IDC

DESCRIPTION

REVISIONS

Digit ally sign ed b y Vale ntin a Br u sati DN: cn =V alen t in a B rusati, o= Saipem , ou , email= valen tin a.b rusati@saipe m.co m, c=IT Date: 2025.04.15 13:39 :39 + 02’00’

VB

VB

BY

Gabrie ll a Alma sio

Gab ri e ll a Alma si o, E = gabr ie l la .al masi o@saip em.co m Reaso n: I ha ve re view ed thi s docum ent Location :

GA

GA

BPB

BPB

15/04/25

09/04/25

CHKD

APVD

DATE

F

G

H

I

J

K

L

A

B

C

D

E

F

G

H

I

J

K

L

Project: Q-32705 - Saipem COMP3 Folder: RFQ Files


Loading authentication...

Graph View

Backlinks

  • 00 Index

Created with Infinity Constructor © 2025

  • Elynox | Go Further