Classification: Internal
1
PLATFORM NORTH
45°
2
3
4
5
6
7
8
9
10
45°
N
TRUE NORTH
TRUE NORTH
PREVAILING WIND
A
0 0 0 0 0 1
,
.
E
C
0 0 0 5 1 1
,
.
E
10000
15000
15000
235-XZ8309
235-XZ8310
12
45°
PREVAILING WIND
E U R T
H T R O N
C
A
11
B
0 0 0 0 3 1
,
.
E
A
B
C
D
E
F
G
H
I
J
K
L
T.O.G. EL. +13632
TO MAIN DECK
UP
UP
235-FE830021
AFFF 135 L
T.O.G. EL. +10032
BOAT LANDING
235-P8704
COAMED
235-XB2011 EL +13650 (B.O.S)
AREA
235-P8703
235-FE830001
9 Kg
BAM 6 (HOLD-1)
235-XB2012 EL +13650 (B.O.S)
235-US-05
2 8 6 2 1 +
235-T8701
. L E G O T
.
.
T.O.G. EL. +10832
T.O.G EL. +9032
TO JACKET DECK
DN
P U
235-V8701
235-XB2013 EL +13650 (B.O.S)
235-P8702
3072
TO BOAT LANDING 12000
DN
T.O.G EL. +12746
N D
TO MAIN DECK
T.O.G. EL. +10812
REMOVABLE HANDRAIL
235-XB2010 EL +13500 (B.O.S)
T.O.G. EL. +10832
7500
REFER DETAIL-1
REFER DETAIL-2
LAYDOWN “C” 2000(L) x 1500(W)
EQUIPMENT LIST
EQUIPMENT NO. 235-T8701 235-US-05 235-P8702 235-P8703 235-P8704 235-V8701 235-XB2010 235-XB2011 235-XB2012 235-XB2013
DESCRIPTION
OPEN DRAIN TANK UTILITY STATION CLOSED DRAIN TRANSFER PUMP OPEN DRAIN WATER PUMP OPEN DRAIN OIL PUMP CLOSED DRAIN DRUM MONORAIL 1 T MONORAIL 1 T MONORAIL 1 T MONORAIL 1 T
SIZE (MM)
3500(L) X 2400(W) X 1500(H)
3070 (L) X 1550(W) X 2260(H) 2630(L) X 1650(W) X 2260(H) 1250 (L) X 500(W) X 500(H) 1500(ID) X 2700(T/T)
UB254 X 146 X 43 UB254 X 146 X 43 UB254 X 146 X 43 UB254 X 146 X 43
235-XZ8312
235-XZ8311
MAX. CRANE RADIUS 35M MAIN HOIST SWL 22.5MT
CELLAR DECK ELEVATION (T.O.S.EL. +10000) FROM EL.+ 9200 TO 14000
13 WHP9S & RP9S KEY PLAN
14
NOTES:
15
16
B
2
1
2
1
C
A
- ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS
UNLESS STATED OTHERWISE.
- PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT,
SECONDARY ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.)
- THE MINIMUM HEADROOM HEIGHT SHALL BE PROVIDED IN ALL
AREA, MEASURED VERTICALLY FROM DECK SURFACE OF LANDING OR PLATFORM.
- THIS LAYOUT SHALL BE USED ONLY FOR QUANTITY AND
LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENT AND DIRECTION OF ESCAPE ROUTES.
- AS PER TECHNICAL SAFETY BASIS OF DESIGN
(200-20-SH-DEC-00013) – FOR OUTDOOR AREAS, THE DEAD END SHALL NOT EXCEED 6 M OF TRAVEL DISTANCE.
B
- THE PORTABLE EXTINGUISHERS LOCATED OUTDOOR SHALL BE
PROVIDED WITH WEATHER-PROOF CABINET.
- WHEELED EXTINGUISHERS LOCATED OUTDOOR SHALL BE
PROVIDED WITH A UV-RESISTANT RED-VINYL COVER. 8. ARROWS SHOWN ON THE ESCAPE ROUTE INDICATE THE
PREFERRED DIRECTION OF EGRESS TOWARDS THE PRIMARY MUSTER AREA. IN CASE OF EMERGENCY AT RP, PERSONNEL SHALL USE BRIDGE TO REACH PRIMARY MUSTER AREA LOCATED AT WELLHEAD PLATFORM RP9S LER BUILDING TR. IN CASE ESCAPE THROUGH BRIDGE TOWARDS WELLHEAD IS NOT FEASIBLE, PERSONNEL TO PROCEED TO SECONDARY MUSTER AREA LOCATED AT RP LER BUILDING TR FOR MUSTERING. 9. LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENT AND DIRECTIONAL ARROWS INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION. 10. STAIRCASES SHOULD ALLOW TRANSPORTATION OF AN
INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.
- ALL FIRE & SAFETY EQUIPMENT SHALL BE LOCATED IN SUCH A
WAY THAT THEY ARE EASILY ACCESSIBLE.
12.BREATHING AIR MANIFOLD 6 PERSON IS PROVIDED, AS PER
TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).
- ALL ESCAPE ROUTES SHALL BE MARKED WITH ESCAPE MARKER PAINTED ON THE FLOOR IN OIL RESISTANT PHOTOLUMINESCENT PAINT THAT IS VISIBLE, DURABLE AND ANTI-SLIP.
N. 114,000
2
LEGEND:
LEGEND
DESCRIPTIONS
QTY
PRIMARY ESCAPE ROUTE 1.12m(WIDTH) X 2.286m (HEAD CLEARANCE) SECONDARY ESCAPE ROUTE 0.76m(WIDTH) X 2.286m (HEAD CLEARANCE) 135L AFFF FOAM WHEELED FIRE EXTINGUISHER
9 kg POTASSIUM BICARBONATE DRY CHEMICAL POWDER (BC) PORTABLE FIRE EXTINGUISHER
LIFEBUOY WITH LIFELINE
AFFF 135 L
9 Kg
BAM 6
BREATHING AIR MANIFOLD CABINET WITH 6 NUMBERS OF HOSE UNIT (NOTE-12)
1
2
4
1
HOLDS: TAG NOS. 1.
235-FE830002
9 Kg
12” - FUEL GAS PIPELINE FUTURE
28” PL9S - PIPELINE TO
RP4S
(FUTURE)
28” PL9S - PIPELINE TO
RP4S
N. 100,000
1
235-23-PI-PLP-00002
EQUIPMENT ARRANGEMENT PLAN CELLAR DECK FOR RP9S
200-20-SH-DEC-00013
TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT
REFERENCE No.
TITLE
REFERENCES
A
A1
NO.
ISSUED FOR REVIEW
ISSUED FOR IDC
DESCRIPTION
MTA
MTA
JB
JB
BPB
13/05/25
BPB
28/04/25
BY
CHKD
APVD
DATE
PROJECT TITLE :
REVISIONS
NFPS Offshore Riser Platforms & Intrafield Pipelines Project - COMP3
Qatar Energy LNG
Qatar Energy LNG
THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.
CONSULTANT / CONTRACTOR :
Saipem S.p.A.
100
0 0 2
100
0 0 2
400
400
TYPICAL DETAIL-1
TYPICAL DETAIL-2
TITLE :
N.T.S
N.T.S
CONTRACTOR DRAWING NO:
033764-H-D00-11-SPM-LP-D-00043-0001
FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - CELLAR DECK - RP9S
1M
0
1M
2M
3M
4M
5M
PROJECT
DRAWING NO.
SHT
SIZE REVISION
033764
235-83-SH-PLN-00001
0001
A1
A
SCALE :
1:100
PROJECT NO. :
LTC/C/NFP/5129/20
A
B
C
D
E
F
G
H
I
J
K
L
1
2
3
4
5
6
7
10
11
12
13
14
15
16
Project: Q-32705 - Saipem COMP3 Folder: 1. 26.06.25