Infinity

Not logged in
Home

❯

Reference Examples

❯

Q 32705 Saipem COMP3

❯

TQ's

❯

Latest Docs provided with TQ

❯

1. 26.06.25

❯

235 83 SH PLN 00001_A

Classification: Internal

1

PLATFORM NORTH

45°

2

3

4

5

6

7

8

9

10

45°

N

TRUE NORTH

TRUE NORTH

PREVAILING WIND

A

0 0 0 0 0 1

,

.

E

C

0 0 0 5 1 1

,

.

E

10000

15000

15000

235-XZ8309

235-XZ8310

12

45°

PREVAILING WIND

E U R T

H T R O N

C

A

11

B

0 0 0 0 3 1

,

.

E

A

B

C

D

E

F

G

H

I

J

K

L

T.O.G. EL. +13632

TO MAIN DECK

UP

UP

235-FE830021

AFFF 135 L

T.O.G. EL. +10032

BOAT LANDING

235-P8704

COAMED

235-XB2011 EL +13650 (B.O.S)

AREA

235-P8703

235-FE830001

9 Kg

BAM 6 (HOLD-1)

235-XB2012 EL +13650 (B.O.S)

235-US-05

2 8 6 2 1 +

235-T8701

. L E G O T

.

.

T.O.G. EL. +10832

T.O.G EL. +9032

TO JACKET DECK

DN

P U

235-V8701

235-XB2013 EL +13650 (B.O.S)

235-P8702

3072

TO BOAT LANDING 12000

DN

T.O.G EL. +12746

N D

TO MAIN DECK

T.O.G. EL. +10812

REMOVABLE HANDRAIL

235-XB2010 EL +13500 (B.O.S)

T.O.G. EL. +10832

7500

REFER DETAIL-1

REFER DETAIL-2

LAYDOWN “C” 2000(L) x 1500(W)

EQUIPMENT LIST

EQUIPMENT NO. 235-T8701 235-US-05 235-P8702 235-P8703 235-P8704 235-V8701 235-XB2010 235-XB2011 235-XB2012 235-XB2013

DESCRIPTION

OPEN DRAIN TANK UTILITY STATION CLOSED DRAIN TRANSFER PUMP OPEN DRAIN WATER PUMP OPEN DRAIN OIL PUMP CLOSED DRAIN DRUM MONORAIL 1 T MONORAIL 1 T MONORAIL 1 T MONORAIL 1 T

SIZE (MM)

3500(L) X 2400(W) X 1500(H)

3070 (L) X 1550(W) X 2260(H) 2630(L) X 1650(W) X 2260(H) 1250 (L) X 500(W) X 500(H) 1500(ID) X 2700(T/T)

UB254 X 146 X 43 UB254 X 146 X 43 UB254 X 146 X 43 UB254 X 146 X 43

235-XZ8312

235-XZ8311

MAX. CRANE RADIUS 35M MAIN HOIST SWL 22.5MT

CELLAR DECK ELEVATION (T.O.S.EL. +10000) FROM EL.+ 9200 TO 14000

13 WHP9S & RP9S KEY PLAN

14

NOTES:

15

16

B

2

1

2

1

C

A

  1. ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS

UNLESS STATED OTHERWISE.

  1. PRIMARY ESCAPE ROUTE: 1.12M WIDTH & 2.286M HEIGHT,

SECONDARY ESCAPE ROUTE 0.76M WIDTH & 2.286M HEIGHT (TYP.)

  1. THE MINIMUM HEADROOM HEIGHT SHALL BE PROVIDED IN ALL

AREA, MEASURED VERTICALLY FROM DECK SURFACE OF LANDING OR PLATFORM.

  1. THIS LAYOUT SHALL BE USED ONLY FOR QUANTITY AND

LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENT AND DIRECTION OF ESCAPE ROUTES.

  1. AS PER TECHNICAL SAFETY BASIS OF DESIGN

(200-20-SH-DEC-00013) – FOR OUTDOOR AREAS, THE DEAD END SHALL NOT EXCEED 6 M OF TRAVEL DISTANCE.

B

  1. THE PORTABLE EXTINGUISHERS LOCATED OUTDOOR SHALL BE

PROVIDED WITH WEATHER-PROOF CABINET.

  1. WHEELED EXTINGUISHERS LOCATED OUTDOOR SHALL BE

PROVIDED WITH A UV-RESISTANT RED-VINYL COVER. 8. ARROWS SHOWN ON THE ESCAPE ROUTE INDICATE THE

PREFERRED DIRECTION OF EGRESS TOWARDS THE PRIMARY MUSTER AREA. IN CASE OF EMERGENCY AT RP, PERSONNEL SHALL USE BRIDGE TO REACH PRIMARY MUSTER AREA LOCATED AT WELLHEAD PLATFORM RP9S LER BUILDING TR. IN CASE ESCAPE THROUGH BRIDGE TOWARDS WELLHEAD IS NOT FEASIBLE, PERSONNEL TO PROCEED TO SECONDARY MUSTER AREA LOCATED AT RP LER BUILDING TR FOR MUSTERING. 9. LOCATION OF FIREFIGHTING, SAFETY, LIFESAVING EQUIPMENT AND DIRECTIONAL ARROWS INDICATIVE ONLY. THE EXACT LOCATION WILL BE BASED ON ACTUAL SITE CONDITION. 10. STAIRCASES SHOULD ALLOW TRANSPORTATION OF AN

INJURED PERSON THROUGH STRETCHER, TO BE CARRIED BY TWO PERSONS.

  1. ALL FIRE & SAFETY EQUIPMENT SHALL BE LOCATED IN SUCH A

WAY THAT THEY ARE EASILY ACCESSIBLE.

12.BREATHING AIR MANIFOLD 6 PERSON IS PROVIDED, AS PER

TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT (200-20-SH-DEC-00013).

  1. ALL ESCAPE ROUTES SHALL BE MARKED WITH ESCAPE MARKER PAINTED ON THE FLOOR IN OIL RESISTANT PHOTOLUMINESCENT PAINT THAT IS VISIBLE, DURABLE AND ANTI-SLIP.

N. 114,000

2

LEGEND:

LEGEND

DESCRIPTIONS

QTY

PRIMARY ESCAPE ROUTE 1.12m(WIDTH) X 2.286m (HEAD CLEARANCE) SECONDARY ESCAPE ROUTE 0.76m(WIDTH) X 2.286m (HEAD CLEARANCE) 135L AFFF FOAM WHEELED FIRE EXTINGUISHER

9 kg POTASSIUM BICARBONATE DRY CHEMICAL POWDER (BC) PORTABLE FIRE EXTINGUISHER

LIFEBUOY WITH LIFELINE

AFFF 135 L

9 Kg

BAM 6

BREATHING AIR MANIFOLD CABINET WITH 6 NUMBERS OF HOSE UNIT (NOTE-12)

1

2

4

1

HOLDS: TAG NOS. 1.

235-FE830002

9 Kg

12” - FUEL GAS PIPELINE FUTURE

28” PL9S - PIPELINE TO

RP4S

(FUTURE)

28” PL9S - PIPELINE TO

RP4S

N. 100,000

1

235-23-PI-PLP-00002

EQUIPMENT ARRANGEMENT PLAN CELLAR DECK FOR RP9S

200-20-SH-DEC-00013

TECHNICAL SAFETY BASIS OF DESIGN (OFFSHORE) FOR COMP3 PROJECT

REFERENCE No.

TITLE

REFERENCES

A

A1

NO.

ISSUED FOR REVIEW

ISSUED FOR IDC

DESCRIPTION

MTA

MTA

JB

JB

BPB

13/05/25

BPB

28/04/25

BY

CHKD

APVD

DATE

PROJECT TITLE :

REVISIONS

NFPS Offshore Riser Platforms & Intrafield Pipelines Project - COMP3

Qatar Energy LNG

Qatar Energy LNG

THIS DOCUMENT IS PROPERTY OF QATARENERGY LNG. THIS DRAWING OR MATERIAL DESCRIBED THEREON MAY NOT BE COPIED OR DISCLOSED IN ANY FORM OR MEDIUM TO THIRD PARTIES, OR USED FOR OTHER THAN THE PURPOSE FOR WHICH IT HAS BEEN PROVIDED, IN WHOLE OR IN PART IN ANY MANNER EXCEPT AS EXPRESSLY PERMITTED BY QATARENERGY LNG.

CONSULTANT / CONTRACTOR :

Saipem S.p.A.

100

0 0 2

100

0 0 2

400

400

TYPICAL DETAIL-1

TYPICAL DETAIL-2

TITLE :

N.T.S

N.T.S

CONTRACTOR DRAWING NO:

033764-H-D00-11-SPM-LP-D-00043-0001

FIRE, SAFETY EQUIPMENT AND ESCAPE ROUTE LAYOUT - CELLAR DECK - RP9S

1M

0

1M

2M

3M

4M

5M

PROJECT

DRAWING NO.

SHT

SIZE REVISION

033764

235-83-SH-PLN-00001

0001

A1

A

SCALE :

1:100

PROJECT NO. :

LTC/C/NFP/5129/20

A

B

C

D

E

F

G

H

I

J

K

L

1

2

3

4

5

6

7

10

11

12

13

14

15

16

Project: Q-32705 - Saipem COMP3 Folder: 1. 26.06.25


Loading authentication...

Graph View

Backlinks

  • 00 Index

Created with Infinity Constructor © 2025