RUWAIS LNG PROJECT
HUMAN FACTORS CHECKLIST FOR VENDORS
COMPANY DOCUMENT REF.
RLNG-000-PM-SP-2501
CONTRACTOR DOC. REF.
215122C-000-JSM-2501
REVISION: 1A
PAGE 1 OF 99 PAGE 1 OF 7
ADNOC GAS
HUMAN FACTORS CHECKLIST FOR VENDORS
COMPANY Contract No.
4700022871
JV TJN RUWAIS Contract No
215122C
Document Class
Class 2
Document Category (for Class 1)
OPERATING CENTER Contract No.
OPERATING CENTER Doc Ref.
1A
1
IFC Issue For Construction
IFC
Issue For
Construction
11-Sep-2024
L. Loine
1-Aug-2024
L. Loine
0
ICR
Issued for Company
19-Jun-2024
L. Loine
Review
A. de Vandière Manikandan Vallivel Masahide Kobayashi
A. de Vandière Manikandan Vallivel Masahide Kobayashi
A. de Vandière Manikandan Vallivel Masahide Kobayashi
S. Deilles
S. Deilles
S. Deilles
Rev.
Revision Purpose
Date
Prepared by
Checked by
Approved by
The terms of Contract / Agreement No: CON22-146 shall apply for any disclosure of this document to any third party.
RUWAIS LNG PROJECT
HUMAN FACTORS CHECKLIST FOR VENDORS
COMPANY DOCUMENT REF.
RLNG-000-PM-SP-2501
CONTRACTOR DOC. REF.
215122C-000-JSM-2501
REVISION: 1A
PAGE 2 OF 99 PAGE 2 OF 7
Table of Contents
Contents
Page
1.0
INTRODUCTION… 4 1.1 Scope of the Document …4 1.2 Holds List …5 1.3 References …5 1.4 Definitions and Abbreviations …5 2.0 HFE (vendor) Checklist … 6 3.0 APPENDIX … 7 3.1 APPENDIX 1 (HFE Checklist Ergonomics Hazard) …7 3.2 APPENDIX 2 (HFE Checklist HMI) …7 3.3 APPENDIX 3 (HFE Checklist Manual Handling) …7 3.4 APPENDIX 4 (HFE Checklist Occupational Health Management Standards) …7 3.5 APPENDIX 5 (HFE Checklist HVAC) …7
The terms of Contract / Agreement No: CON22-146 shall apply for any disclosure of this document to any third party.
RUWAIS LNG PROJECT
HUMAN FACTORS CHECKLIST FOR VENDORS
COMPANY DOCUMENT REF.
RLNG-000-PM-SP-2501
CONTRACTOR DOC. REF.
215122C-000-JSM-2501
REVISION: 1A
PAGE 3 OF 7 PAGE 3 OF 99
Table of Changes compared to previous revision (for Procedures and Job Specifications only)
Paragraph
Modification description
Remarks / Origin
New document
No change from a previous one.
6.5
Correction of 1st §6.5 which should be 6.1.2
Cross reference default
The terms of Contract / Agreement No: CON22-146 shall apply for any disclosure of this document to any third party.
RUWAIS LNG PROJECT
HUMAN FACTORS CHECKLIST FOR VENDORS
COMPANY DOCUMENT REF.
RLNG-000-PM-SP-2501
CONTRACTOR DOC. REF.
215122C-000-JSM-2501
REVISION: 1A
PAGE 4 OF 7 PAGE 4 OF 99
1.0
INTRODUCTION
The ADNOC Ruwais LNG Project is a two train, near net-zero electrically driven LNG facility, targeting international markets. The feed gas for the project is supplied from the Habshan Gas Processing Plant via a new export gas pipeline. The plant will have two 4.8 MTPA (nominal capacity) electric driven LNG Trains with associated LNG storage/marine export facilities and utilities.
Figure 1
Project Context
The ADNOC Ruwais LNG Project foresees the following main components at the facility:
Onshore LNG Liquefaction facilities for 2 x 4.8 MTPA electrically driven LNG Trains (9.6MTPA total)
Common facilities including inlet receiving facilities, LNG storage, BOG handling, flare, refrigerant
storage and support buildings.
Utilities to support the facilities including import power from the national grid.
Marine facilities for LNG export and bunkering.
1.1
Scope of the Document
Human Factors Checklist consist as useful tool to check if Vendor package is compliant with HFE requirements.
HFE Requirements have been detailed in HFE Specification and the attachment in this specification contains a checklist which has to be filled by :
Vendors.
-
Requisition Engineer, in coordination with HFE engineer shall verify that vendor has implemented HFE requirements through: General Arrangement Drawings from vendor documentation / Vendor 3D Model (if applicable) / 3D Model Review and Inspection site review (when required). If non- identified deviation is found, Vendor has the responsibility to resolve the issue.
Inspector (or person in charge of) to cross-check that vendor has delivered this package in line with drawings and HFE project requirements as described in Human Factors Engineering Specification
-
Vendors will ensure that a focal point is assigned interface for responsibility for Safety Critical Tasks and Errors Inventory identification and assigning responsibility for conducting human reliability review internally where applicable.
-
During Project execution, HFE reviews will be performed with Vendors, close out report will be
attached.
The terms of Contract / Agreement No: CON22-146 shall apply for any disclosure of this document to any third party.
RUWAIS LNG PROJECT
HUMAN FACTORS CHECKLIST FOR VENDORS
COMPANY DOCUMENT REF.
RLNG-000-PM-SP-2501
CONTRACTOR DOC. REF.
215122C-000-JSM-2501
REVISION: 1A
PAGE 5 OF 7 PAGE 5 OF 99
1.2
Holds List
HOLD
DESCRIPTION
1
2
1.3
References
[1] RLNG-000-PM-PP-2501 [2] RLNG-000-SE-RP-0001
HUMAN FACTORS ENGINEERING SPECIFICATION DESIGN HSE PHILOSOPHY
1.4
Definitions and Abbreviations
COMPANY
CONTRACTOR
CCR EERA EPC ADOC POC YOC HMI
ABU DHABI NATIONAL OIL COMPANY (ADNOC) P.J.S.C. TJN Ruwais, Joint Venture of Technip Energies France-Abu Dhabi, JGC Corporation and National Marines Dredging Company (NMDC) Central Control Room Escape, Evacuation and Rescue Assessment Engineering Procurement Construction Abu Dhabi Operating center - National Marines Dredging Company Paris Operating Center - Technip Energies Yokohama Operating center - JGC Corporation Human Machine Interface
The terms of Contract / Agreement No: CON22-146 shall apply for any disclosure of this document to any third party.
RUWAIS LNG PROJECT
HUMAN FACTORS CHECKLIST FOR VENDORS
COMPANY DOCUMENT REF.
RLNG-000-PM-SP-2501
CONTRACTOR DOC. REF.
215122C-000-JSM-2501
REVISION: 1A
PAGE 6 OF 7 PAGE 6 OF 99
2.0
HFE (VENDOR) CHECKLIST
The terms of Contract / Agreement No: CON22-146 shall apply for any disclosure of this document to any third party.
RUWAIS LNG PROJECT
HUMAN FACTORS CHECKLIST FOR VENDORS
COMPANY DOCUMENT REF.
RLNG-000-PM-SP-2501
CONTRACTOR DOC. REF.
215122C-000-JSM-2501
REVISION: 1A
PAGE 7 OF 99 PAGE 7 OF 7
3.0
APPENDIX
3.1
APPENDIX 1 (HFE Checklist Ergonomics Hazard)
3.2
APPENDIX 2 (HFE Checklist HMI)
3.3
APPENDIX 3 (HFE Checklist Manual Handling)
3.4
APPENDIX 4 (HFE Checklist Occupational Health Management Standards)
3.5
APPENDIX 5 (HFE Checklist HVAC)
The terms of Contract / Agreement No: CON22-146 shall apply for any disclosure of this document to any third party.
Attachment 1 - HFE (Vendor) Checklist,
Package / Area / Unit:
Item:
Vendor Name:
PO No:
Prepared by (Vendor):
Date of Preparation:
Reviewed by (Contractor):
Date of Review:
checklist is prepared as a compliance checklist and as a practical tool for Vendors. It should be noted that the package designs should comply with all relevant requirements in the HFE Specification, even if not detailed here. Please use just the relevant parts of the checklist! Requirements have been added when AGES-SP-03-004 refer to other references.
AGES-SP-03-004 HFE Specification with the cover page RLNG-000-PM-PP-2501_1 Human Factors Design Specification
Note: When HFE Specification refers to other documents, the checklist has been improved with appropriate requirements from such documents to be consistent as a whole.
IMPORTANT NOTE 1
Please be informed of the following clause of the HFE Specification before proceeding with the checklist!
IMPORTANT NOTE 2
Deviations from this standard are only acceptable where the MANUFACTURER has listed in his quotation the requirements he cannot, or does not wish to comply with, and the COMPANY / CONTRACTOR has accepted in writing the deviations before the order is placed.
In the absence of a list of deviations, it will be assumed that the MANUFACTURER complies fully with this standard.
Any technical deviations to the Purchase Order and its attachments including, but not limited to, the Data Sheets and Narrative Specifications shall be sought by the MANUFACTURER only through Concession Request Format.
Concession requests require CONTRACTOR S and COMPANY S review / approval, prior to the proposed technical changes being implemented. Technical changes implemented prior to COMPANY approval are subject to rejection.
The INDEX area below before the checklist section is created as an aid to show the relevant areas of the checklist to help the Vendor to focus only to the relevant areas.
Please select the areas applicable or which are part of your scope below for your convenience!
The clauses of the HFE Specification and this Checklist are the same. So, if within this checklist a reference to a certain section of the HFE Specification is made, it will be the same reference to the relevant clause in this checklist.
IMPORTANT NOTE 3
Page 1 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
I N D E X for HFE Specification Clauses and Areas
Topic / Scope (Numbering is in line with Specification)
Applicable
Vendor Remarks
Contractor Remarks
The selection of relevant clauses might be performed by the Requisition Leader (RL) in coordination with the related Package Engineer (PE).
6
PLANT LAYOUT AND DESIGN
6.1
Equipement and Instrumentation
6.1.1
Operability and Maintainability
6.1.1.1
Body Position
6.1.2 - Layout
6.1.2.1 Operation Handling
6.1.2.2 General Safety Considerations
6.1.3
Pipework
6.1.4
Manways/Access Openings
6.1.5
Access and Egress
6.1.6
Emergency Egress
6.1.7
Working Environment Area Limits
6.1.8
Maintenance and cleaning
6.1.9
Storage and laydown Areas
Page 2 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
Topic / Scope (Numbering is in line with Specification)
Applicable
Vendor Remarks
Contractor Remarks
I N D E X for HFE Specification Clauses and Areas
6.2
Valves
6.2.1 General
Stairways, Ladders, Platforms, Walkways and
6.3 Railing
6.3.1 Specific requirements Applicable to Stairs and
Stairways
6.3.2 Fixed Ladders
6.3.3 Walkways and platforms
6.3.4 Handrails
6.3.6 Flooring/Surface materials
6.4
Anthropometric Range
6.5
Signage and labelling
6.5.1 General
6.5.2 Safety Signs
HUMAN MACHINE INTERFACE & RELATED
7 INSTRUMENTATION REQUIREMENTS
7.1 - Alarms
Page 3 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
Topic / Scope (Numbering is in line with Specification)
Applicable
Vendor Remarks
Contractor Remarks
I N D E X for HFE Specification Clauses and Areas
7.1.1 General Principles
7.1.2 Visual Alarms
7.1.3 Audible Alarms and Warnings
7.1.4 Warnings devices
7.1.5 Control/Display/Alarm integration
7.1.6 Escape and Evacuation Alarms
7.2 Local Control and Display Panels
7.2.1.1 Additional instrumentation Requirements
7.3 - Instrumentation
7.4
Control Panel Signage and labelling
7.5
Human Machine Interface (HMI) Design
7.5.1 Display Design
7.5.1.1 Display Hierarchy
7.5.1.2 Display Contents
7.5.1.3 Display Layout
7.5.1.4 Text
7.5.1.5 Display Color
7.5.1.6 Data Entry
Page 4 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
Topic / Scope (Numbering is in line with Specification)
Applicable
Vendor Remarks
Contractor Remarks
I N D E X for HFE Specification Clauses and Areas
7.6
Control Room Design and Layout
7.7
Remote Operations
8
Manual Handling and lifting requirements
9
Working environment
9.1 - Noise
9.1.1. Nuisance Noise
9.2. Lighting
9.3 Vibration
9.4 Temperature
9.5 Ventilation
9.6 Weather Protection
10
Human reliability and performance
10.1.1.4 Color Vision
10.1.1.5 Visual Acuity
10.1.3.2 Perception
10.1.3.4 Decision making
Page 5 of 78
Package / Area / Unit:
Item:
Vendor Name:
PO No:
Attachment 1 - HFE (Vendor) Checklist
Mutual Confirmation on Compliance of HFE Specification Requirements (That confirmation covers the pages above and below)
VENDOR
CONTRACTOR
Name:
Signature:
Name:
Signature:
Page 6 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
6
PLANT LAYOUT AND DESIGN
6.1
Equipement and Instrumentation
Is the facility designed so that work areas where there may be exposure to hazards (e.g. noise, chemicals) such as the process areas,
control-rooms, living quarters and recreational areas ?
6.1.1
Operability and Maintainability
See also AGES-SP-09-001 Piping Basis of Design (relevant requirements have been added in this checklist)
Does the plant and layout design allow for easy access for operation and maintenance under normal, abnormal and emergency conditions, during all weather conditions by 90% of the full range of potential employees ?
Does the facility base on designing for the anthropometric variability, taking a size range of potential users from the 5th percentile females to 95th percentile males, and also reflect the multi-ethnic mix of the working population (see section 6.4)?
Does the design consider the personal protective equipment (PPE) requirements and how wearing of PPE impacting accessibility (e.g.
personnel, wearing breathing apparatus can impact access requirements)?
The plant layouts for new construction, expansions and modifications on existing facilities shall provide for a maximum of safety and
Page 7 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
exposure protection from the spread of fire, with ease of operation and maintenance consistent with economical design.
Risk assessment should be considered for plant expansion, modifications, revamping and also for installation of temporary facilities.
The inspection of the equipment, for both new and existing plant modifications, must be given adequate consideration during all the stages from initial design through shop manufacture, site fabrication or erection, commissioning and subsequent operation. It shall be ensured that equipment has been designed, fabricated and installed according to the Specifications, Codes and Standards approved by COMPANY.
Fired heaters /Furnaces
Where required, platforms shall be installed to facilitate operation and maintenance. The operating platform at the burner control side shall be 1.8 m wide, and the other sides of this platform shall be 1.2 m wide.
Bottom fired heaters should have 2.1m clearance for burner removal.
The utility station provided shall be located in such a way that they are easily accessible approximately 1.2 m above grade level or elevated platforms from the main passage to provide for the maintenance, purging and cleaning requirements of equipment such as exchangers, pumps, compressors, furnaces, vessels/columns (vessels require a utility station at each manhole) etc.. The piping shall be securely bolted to a supporting structure.
Page 8 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Any connection that is expected to be disassembled shall be provided with an upstream double block-and-bleed valve arrangement to protect personnel.
Does the minimum space provided for standing operator or maintenance worker is 700mm wide x700mm depth x 2100 mm?
Does the minimum squatting or kneeling space provided is 900mm wide x 900mm depth x 1300mm?
For workspaces that require the operator to be prone of crawling, does the cross-sectional area is a minimum of 700mm wide x 900mm high?
Note: If crawling is required, then the travel distance required shall be minimized and is subject to approval by the COMPANY HFE Technical Authority.
Does the operability of equipment ensure the usability of display and control design including local control panels?
Do any screens, gauges, sight glasses etc., are easy to read from standing position on the floor or from a platform (see section 10.1.1.5 on visual acuity)?
Does the design ensure efficient and safe movement of equipment requiring maintenance without removal of other items such as piping, motors, etc?
Do hatches are capable of being secured in the open position?
Page 9 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Do Access openings are side hinged with handgrips on both sides of the opening?
6.1.1.1
Body Position
See also HST-OH-ST11 for REBA and RULA Main requirements from this reference have been added in this checklist (Added checklist in appendix 1).
Do the dimensions of the workspace consider the range and flexibility of their limbs and body?
Do tasks designed to avoid causing the arms to work above the shoulder?
Does work that causes the spine to be twisted is avoided?
6.1.2 - Layout
Does a consistent approach minimizing human error risk to equipment location and identification has been performed?
Does equipment layout and equipment numbering consider how operators view the equipment and conform with cultural expectations, languages and local stereotypes (E.g., equipment should be laid out and labelled 1, 2, 3/A, B, C from left to right as the operator would normally look at them (unless the local stereotype is right to left) or top to bottom, valves are clockwise to close, red is stop etc.?
Does the layout allow a logical workflow and efficient access for routine operations?
Page 10 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Does the layout allow operational and maintenance tasks to be conducted without operators and maintenance staff requiring to be repeatedly moving on and off or up and down units?
Where multiple trains or similar equipment are installed, does mirroring of layout not used?
Does layout of equipment related to Safety Critical Equipment, Process Critical items from HAZOP studies or items that reduce the safety and efficiency of the process when removed due to maintenance and therefore need rapid maintenance is prioritized for accessibility?
Does sufficient space is ensured around major equipment (e.g. turbines, compressors) for the lay down of the heavy machine parts during maintenance?
Does The arrangement accommodate the expected number of personnel required to perform all operational or maintenance tasks associated with the equipment, including their requirements for tool use, test equipment and manual handling equipment?
Does space to accommodate any transport devices required to move equipment to and from area has been provided?
Has Sufficient clear headroom been provided under elevated platforms where personnel are required to gain access for operations and/or maintenance and/or where through access is permitted?
Page 11 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Do flushing, draining and venting facilities are located such that these activities can be operated in a logical sequence and can be accessed easily?
Is Portable equipment designed to be easily maneuvered around the facility, and minimize the manual handling required by the operator or maintenance team?
Potential hazards associated with process conditions, equipment layout, ignition sources, fuel sources, toxic releases, chemicals etc., shall be considered during facility layout design stage.
The more hazardous equipment should be located downwind.
Minimize the requirement for people to be in hazardous areas.
Areas containing hydrocarbons should be open and well-ventilated to prevent an accumulation of escaping gas and to provide better venting in the event of an explosion thus reducing blast overpressures.
Access shall be ensured for thorough and timely inspection of the production equipment including stationary and mobile cranes, overhead cranes, structures, storage tanks, boilers, pressure vessels, piping and related pressure containing equipment.
Areas shall be designated as necessary to allow maintenance of equipment such as disassembly of pumps, compressors, tube bundle removal of exchangers, etc. Such maintenance areas shall not interfere with escape routes.
Page 12 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
For buried pipes operating at a temperature of 60°C or below, there shall be a clear distance of at least 300 mm between the pipe and any electrical or instrument cables.
For buried pipes operating above 60°C, there shall be a clear distance of at least 600 mm between the pipe and any electrical or instrument cables.
6.1.2.1 Operation Handling
Do Product loading or draining operations require any manual handling of drums on stairs?
Are handling requirements for stored equipment or materials, including consumables, considered and adequate space, including maneuvering space, provided?
Are couplings and their guards accessible from both sides?
Permanent handling facilities for maintenance access shall be maximized as practical as possible.
The material handing studies shall be carried out based on the available material handling crane capacity with the COMPANY work areas for routine maintenance and repair activities during normal operations.
6.1.2.2 General Safety Considerations
Do all machinery and equipment, including any attachments and connections, designed, constructed, located, insulated, and/or guarded to prevent accidental or personnel contact with any part that
Page 13 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
could injury due to motion, temperature, pressure, sharpness or electrical charge?
Are special tools provided for removal of guards?
Do sharpes edges avoided wherever these could pose an injury risk to personnel?
Are any atmospheric vents located and oriented away from access ways?
Where stored energy devices are necessary, are safety features such as removal tabs, lockouts, and warning placards provided?
Is both the presence of a hazard and the fact that an interlock exists noted on the equipment case or cover such that it remains visible when the access is open?
Are manways, access hatches, hand holes, inspection ports, coupling guards, junction boxes and all covers requiring removal for operations or maintenance access to internals fully accessible without any obstruction or restriction by platform structures, ladders, railings,
Provide for personnel escape and evacuation in the event of an emergency.
Position safety equipment in appropriate locations.
Eye washing fountains and emergency showers shall be provided near equipment or pipe manifolds where operating personnel would be subjected to hazardous sprays or spills such as acid, caustic, or phenol
Page 14 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
be installed at a location conveniently accessible for emergency use.
Minimum distance of the eyewash & shower from hazard shall be no closer than 3m (10ft) and no more than 15m (30ft).
Eye washing fountains and emergency shower heads shall be suitable for outdoor installations in line with HSE requirements.
Primary access: stairs only
Secondary access can be ladder, provided its designed for escape donning SCBA/EEBA.
Operator access to equipment and grade level instruments should be provided between the edge of equipment and the pipe rack (for pipe rack inside the plant). For outside the plant pipe racks, paved/interlock paved operator access shall be provided below the rack.
Emergency escape gates are required in perimeter fencing, e.g., in
locks/fixtures.
6.1.3
Pipework
Is a minimum of 750mm provided as clear access in the front of valve?
The minimum clearance between any pipe flange and equipment, walls, structural supports etc., shall be as defined AGES-SP-09-001 Piping Basis of Design Table 1 hereunder.
Page 15 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Page 16 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Page 17 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Page 18 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Are Adequate spaces allowing for the installation/removal of blinds and the swinging of spectacle plates?
In general clearances stated in AGES-SP-09-001 shall be followed as a minimum. In case of conflict the more stringent shall apply.
Unless specifically indicated on the P&IDs, control valves shall preferably be located at grade.
Piping and pipe supporting structures shall be designed so that cranes and trucks access is provided for maintenance or removal of valves, in-line instruments, tube bundles and shell / channel covers and for operational reasons.
Piping layout shall not result in tripping hazards.
Flanges on a vertical pipe or vessel nozzle that penetrates through deck shall have a minimum of 150 mm gap or space required for hydraulic bolt tensioning whichever is higher, between the top of the kick plate and the flange bottom nut surface to allow sufficient space for a wrench and a hand.
6.1.4
Manways/Access Openings
Are manways and access designed to account for the operator wearing PPE, weather protective clothing and any required breathing apparatus?
Does The design also consider the access for required tools, equipment (including ladders if required) and materials, and emergency rescue requirements?
Page 19 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Are opening sizing consider the anthropometric data of the workforce and increased accordingly?
If manways and access ways on roofs of vertical storage, are they located at the perimeter of the tank with appropriate platforms, guard rails and stairs or ladders?
Man-ways should be on or about a longitudinal centerline of vessel. Permanent platforms shall be provided at manways above 3.0 m centerline elevation from highest point of finished surface to ensure minimum headroom clearance is available below the platform pressure vessel.
Manholes should be located on a common center line and access platforms should be located on the access aisles for columns/Towers and vertical vessels.
Cement-lined pipes for cooling water application with sizes NPS 36 and larger shall be provided with inspection hand hole of minimum size NPS 8 and maintenance manhole of minimum size NPS 24. The distance between manholes should be no more than 100m.
6.1.5
Access and Egress
Can all areas of the facility and equipment be accessed and evacuate safely under normal and emergency conditions and whilst wearing PPE?
Are Access designed in the following order of precedence:
a. Access direct from the grade or the floor b. Ramps
Page 20 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
c. Stairs d. Permanent inclined stepladders or spiral staircases e. Permanent vertical ladders
If access is required daily, then the access shall be by options a, b, c. Options d and e can be used when access is required less frequently.
Temporary access, such as mobile platforms or scaffolding, should only be used if access is required less than once a year.
When trolleys, carts or other wheeled mobile equipment may be used, are Access ways laid out with ramps between 7° and 15°?
Are any outdoor handles, door switches etc., designed to be operable while wearing gloves?
Access and escape routes from tankage areas should be directed away from the inner area of combined tanks.
6.1.6
Emergency Egress
See also Emergency Egress, Evacuation and Rescue requirements are covered by HSE-RM-ST07, HSE-GA-ST07 and AGES-GL-03-001. See Appendix 2
Stairways shall connect directly to egress routes.
The bottom flight of stairs to grade level onshore shall be orientated away from the plant, similarly offshore at each emergency access level, the orientation of the flight of stairs landing on that level shall be orientated towards the main emergency egress.
A minimum of two alternative egress routes are required from all areas of the platform back to the Safe Area / Temporary Refuge.
Page 21 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
The muster location must have adequate space to accommodate maximum headcount anticipated at the facility, with a minimum of 0.35m2 per person, or 0.75m2 per person where EEBA and PPE is required.
Flashing Alarm Beacons shall be located in all high noise areas (>85 dB (A)) and in areas where high noise levels are anticipated during emergencies.
Manual Alarm Call Points (MACs) shall be provided at strategic locations including egress points.
Note : The location of MACs shall be designed such that they are readily accessible.
Unless otherwise specified, the minimum width and height of escape routes shall be 1.2m and 2.3m respectively.
All means of access shall allow easy passage pf personnel wearing self- contained breathing apparatus.
For special cases such as unmanned wellhead tower, the escape route width can be optimized to 1.0m subject to ADNOC Group approval.
6.1.7
Working Environment Area Limits
Are Clearances and distances follow the guideline Table 6-1 of AGES- SP-03-004 hereunder?
Note: these figures should be adjusted where required to account for anthropometric data of the local workforce.
Page 22 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Page 23 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Page 24 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
6.1.8
Maintenance and cleaning
Are all materials and surfaces, including structural members, installations, equipment, cameras, light fittings etc., easy to clean and maintain?
6.1.9
Storage and laydown Areas
Are Areas for storage located in the vicinity and on the same level?
Page 25 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Are storage rooms located so that transport to and from, and lifting operations are straightforward?
6.2
Valves
6.2.1 General
Are operability and maintainability of valves in accordance with the assigned Valve Criticality analysis category (Table 6 2 hereunder)?
Page 26 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Valves should be positioned with their stems pointing upwards; however, horizontally pointing stems and intermediate positions may be accepted on case to case basis.
Valves shall not be installed with their stem below horizontal except for gate valves in Flare piping.
Since drain valves in liquid service with design temperature below - 46°C shall be installed with the stem in the vertical position, the drain
Page 27 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
connections require a support/bracing. The drain connection should be braced to the process line.
Irrespective of frequency of use, larger valves may require power operation (this may be pneumatic, hydraulic or motor driven) and the need for this shall be assessed. Refer to AGES-GL-08-005 P&ID/PFD Development Guidelines.
Are valves oriented and positioned such that spindles, hand wheels or handles do not protrude into designated access ways, including off skid access ways?
Do Sufficient space preserved around valves and valve actuators to allow for the use of tools and the removal of parts, and/or entire valve, during maintenance?
Note: This applies equally to clearance from top of base plate / platform to bottom of flange for removal of flange bolts for valves at low elevation such as drain valves.
Are valves that are operated and maintained from elevated access platforms accessible within the confines of the platform?
Note: Any exceptions should require specific review and approval.
Is minimum 75mm hand clearance provided around all valve hand wheels and levers over the full range of available travel?
Valve handwheels shall meet AGES-SP-09-003 Piping and Pipeline Specification. However, for operational ease, it is recommended that valve handwheels should not be larger than 460mm in diameter.
Page 28 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Are handwheels designed with one or more of the following to aid the
Knurling Indentation
- High Friction Covering
Are Valve position indicators located and oriented such that the
The Maximum cracking force required to operate any large valve (with a handwheel diameter > 125mm or lever length > 125mm), without hindrance, is not to exceed 360N.
For smaller valves that are deemed one handed operation (handwheel between 50mm and 125mm), a maximum cracking force is not to exceed 66N.
The force required to operate manual valves (once the valve has been cracked) is to not exceed 147N for valves with hand wheels above 125mm or levers above 125mm long.
Any valve that requires more than 80 turns to go from fully open to fully closed should be equipped with a motorized actuator.
Remote Valve Operators (RVO) or mechanical extenders should be used to operate valves that cannot be located within the reach limit distances specified in below where direct operation would expose the
operator to hazards (e.g., confined space or where noxious fugitive emissions may be present).
Page 29 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Page 30 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Valves should be self-lubricating or allow easy manual lubrication.
VC1 valves with hand wheel diameters larger than 400 mm and/or those requiring a reasonable (>165 N) cracking force to operate shall be located between 900 mm (optimum) and 1000 mm above the standing surface for hand wheels in the horizontal plane; and between 1100 mm and 1300 mm above the standing surface for hand wheels in the vertical plane (these figures should be adjusted to suit anthropometric data for the workplace population if required).
Where a number of valves having the same VCA rating are located together, and the piping arrangement does not allow for all to be at the preferred position, then the following order of priority should be given to the valves:
i. The valve requiring the greatest physical force to operate.
ii. The valve or valves requiring two-handed operation.
iii. The valve or valves requiring single-handed operation.
In all cases there should be no object preventing the operator from standing right at the valve hand wheel or lever. Where a barrier (e.g., handrail) is allowed for smaller valves, reach distance shall not exceed 500mm.
Safety valves shall be accessible. Wherever feasible, they should be located on platforms which are designed for other purposes. Safety valves with a centerline elevation over 2m above the high point of finished surface shall be accessible from a platform.
Page 31 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Emergency shutdown (ESD) and major isolation valves are to be preferably located at grade level or shall be provided with good and safe access and be located a minimum of 15 m horizontally from the equipment protected or as defined in Facility Layout and Separation Distances Guidelines AGES-GL-03-001.
6.3
Stairways, Ladders, Platforms, Walkways and Railing
Ladders should be used for angles between 50° and 90° (preferred range is 0° to 80° for step ladders, preferred range for ladders is 75° to 85°).
Stairs should be used for angles between 30° and 50° (preferred range is 30° to 40°) including for rescue in the H2S Zone.
6.3.1 Specific requirements Applicable to Stairs and Stairways
Stairways should be provided whenever operators or maintenance workers must change elevation abruptly by more than 250mm
If steps are wider than 2400mm, they shall be separated into several parts by one or more handrails, so the width of each part does not exceed 2400mm and is not less than 800mm high.
Page 32 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
landings and floors (t is thread depth). On the same flight, h shall be constant. Where it is not possible, the rise of the first step in the flight, h1, may be reduced by maximum of 15 %. The maximum riser height for an individual step shall be 300mm.
The leading edge of the stair tread shall be of a contrasting color for a minimum width of 38mm.
6.3.2 Fixed Ladders
Fixed ladders should not be the primary method of escape. They are acceptable for access to platforms that are used less than once a week.
The maximum height of a single run ladder shall be 9m. however if there are several runs of ladders, the height of each single ladder shall be a maximum of 6m.
Page 33 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Fixed ladders shall be attached to permanent structure and should not be attached to removable items or interfere with the removal of any other items or equipment.
Ladders shall be for access only. Personnel should not be conducting any task from the ladder. There shall be no manual handling or lifting of any load via ladders.
The exit/entrance access to the top of the ladder should be a side- step orientation.
A self-closing safety gate covering the full width of the ladder opening shall be installed at the top of each ladder.
Note: Chains shall not be used.
Ladder landings/platforms shall be independent of primary and secondary escape ways and other access ways.
6.3.3 Walkways and platforms
Platforms should be provided wherever operators or maintenance staff are required to use two hands to perform a task.
Effective fall protection is to be provided on stairs, ladders, and platforms at or above 1800mm.
Note: If the workforce is exposed to a potential fall of equal to or more than 1800mm, safety belts or harnesses shall be used.
Elevation changes in walkways and access routes shall be avoided. The greatest height difference between adjacent floorings shall be less than 4mm. Gaps between adjacent flooring shall be less than 20mm.
Page 34 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
6.3.4 Handrails
Handrails for walkways and stairs should be continuous, including the transition between walkways, platforms, and stairs.
Handrails should be provided on stair landings and at the edge of any floor where there is a drop of more than 500mm to grade or the adjacent level
Handrails should be provided on both sides of stairways with more than 3 steps.
The vertical height of the handrail shall be between 900mm and 1000mm above the step and a minimum of 1100mm above the walking level on the landing.
Handrails should be smooth, continuous, circular in cross section and be between 25mm and 50mm outside diameter. It should provide a good grip for the hand.
6.3.5 Landings
The width of landings should be at least as wide as the stairways but have a minimum width/length of 900mm.
Landings on primary escape routes and routes where stretcher access is required should have a minimum width of 1200mm and 2200mm long.
Where there are changes in direction it is recommended that landings should be a minimum of 1778mm in length and 2900mm wide to accommodate rotating the stretcher.
Page 35 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
The maximum height between stairway landings shall be 3650mm. For tanks, a landing should be provided for every 6000mm of vertical rise.
Stair landings shall be independent of primary and secondary escape ways and other access ways.
6.3.6 Flooring/Surface materials
Slippery floor surfaces shall be avoided in work areas and access ways.
All access ways shall be self-draining.
Non-slip alternatives shall be installed in exposed stairways and ladders. They shall remain non-slip when wet, oily etc.
The surface of every stair tread is to extend across the full width of the stair and be slip resistant.
Grating/openings in floorings shall be less than 35mm.
If there is a risk from falling objects to people below, the grating/openings shall be 25mm or less.
6.4
Anthropometric Range
See ISO 15535.
6.5
Signage and labelling
6.5.1 General
All units of equipment, including valves, instruments, control panels etc. should have identifying labels.
Page 36 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
These labels should be securely attached, permanent, non-fading, chemical and solvent resistant, corrosion resistant and abrasion resistant. Labels should preferably be engraved plastic.
Equipment labels should be located so that they are visible and readable with the equipment in its installed position (see 10.1.1.5 on Visual Acuity).
Labels should be located (preferably above) so they are not obscured from the operator when operating the associated equipment (e.g., the operator s hand should not obscure the label when the operator is
carrying out a task).
Labels on similar units of equipment should be placed in approximately the same location on each.
Labels should be located so that they can be read from the operator s normal work position or station and should read from left to right (unless the local stereotype is right to left) or top to bottom (allowed).
Labels shall be concise and unambiguous. The amount of information on the label is to be sufficient to convey a clear message to the intended user. Clear and complete words should be used. Acronyms and abbreviations should be avoided. Excessive detail, redundant words, phrases, and information should be avoided.
All characters should be of adequate size and with a choice of a simple block font suitable for ease of reading and understanding. The font size shall be large enough so that the label can be read from the
Page 37 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
operator s normal work position. See Section 10.1.1.5 for further information on visual acuity.
Labels should be of high contrast, preferably black text on a white background.
All labels shall be in the appropriate language/languages for the workforce (typically English and Arabic).
For labels of more than three words, mixed upper/lower case text shall be used.
Trade names, logos, equipment model, contract numbers, or any other information not directly required by the user to accomplish operational, or maintenance tasks should be avoided on the face of displays, control panels, and consoles. Where such information is provided it should be on the back or side of the panel.
Techniques including unique labelling, color coding or similar should be employed to distinguish between process trains. However, if color coding is used it shall not the sole means for indication.
6.5.2 Safety Signs
See all safety signs shall also conform with the requirements of HSE-OS-ST27 Hazard Communications Standard.
The frames of escape gates shall be painted RAL 1004 Golden Yellow and illuminated for easy identification in an emergency.
7
HUMAN MACHINE INTERFACE & RELATED INSTRUMENTATION REQUIREMENTS
7.1 - Alarms
Page 38 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
7.1.1 General Principles
Alarm prioritization is to be accomplished using three priority levels and is to be based on a continuum of importance, severity, or time- based need for operator action.
Each alarm should prompt a unique action or response (e.g., monitoring). If there is no action required, there should be no alarm. If multiple alarms all prompt the same action, there should only be one alarm with the visual alarms denoting each system sending the audible alarm signal.
A notification that has no associated panel operator action as stated above shall be considered as an alert or message (sometimes called ) and logged in the system for any post-event analysis or to journal be used as historical data.
Cues for prompt recognition of out-of-service alarms should be designed into the system. The system should log the operator who initiated out-of-service alarm together with date/ time/ authorization details.
Further, system should all reporting of all the out-of-service alarms on demand and at the end/ start of each operation shift.
The limits or set points for initiating the annunciator warning system should be established to meet the following goals:
i. Alarms should not occur so frequently as to be considered a nuisance by the operators.
Page 39 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
ii. If applicable, the limits or set points that initiate an alarm or warning display should be set so that the alarm gives operators adequate time to respond to the condition before it becomes more serious.
iii. If it is possible for an alarm to be ON or disabled for an extended period during normal operations (e.g., for equipment repair), the alarm is to be distinctively coded for positive recognition during this period.
For control panels, a control to test the auditory signal and flashing illumination of alarms is to be provided.
Repetitive groups of alarms should have the same arrangement and relative location at different workstations. Any alarm controls (e.g., acknowledge, reset, clear) should be consistent from panel to panel.
For the brown-field works and the facilities being added as the part of existing process area the existing HMI and associated philosophy/ practice should be considered.
7.1.2 Visual Alarms
For Control workstations and local control panels visual alarms shall have:
a. Sufficient contrast between illuminated versus non-
illuminated alarm banners and flashing versus steady on b. alarms is to be provided so that operators can easily and
instantaneously discern each state.
c. Color coding is to be consistent across all alarm displays and
shall reflect alarm priority.
Page 40 of 78
Package / Area / Unit:
Item:
Vendor Name:
PO No:
Attachment 1 - HFE (Vendor) Checklist
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
POINTS TO CHECK (Categorized into main HFE Areas)
d. Conspicuousness of color coding of alarms should reflect
alarm priority and state.
e. Due to the possibility of the operator having impaired color vision, color coding should not be used on its own but as a secondary indication. Other methods such as text, shape, shading or contrast shall be used as a primary means. Alarm priorities shall be displayed using at least three distinct visual features inclusive of distinct color codes, distinct alarm prompt shapes, distinct text for each alarm priority.
f. e. If the visual alarm is important then it shall be located to
7.1.3 Audible Alarms and Warnings
A signal-to-background noise ratio of at least 10 dB(A) is to be provided at the operating position of the intended receiver.
No audible alarms should exceed 110 dB(A) without specific written approval
Completion of a corrective action is to automatically terminate the audible signal
Acceptable priority coding methods for audible signals include a combination of pulse coding, duration, frequency, intensity change, and shape change may be used as designated by EEMUA 191.
Audible signals should have a frequency range between 200 and 5000 Hz.
Page 41 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
For a quick response time, a 800 t0 100Hz every 1.4 seconds) or a beep (415Hz, on for 0.7 seconds, off for 0.6 seconds) are ideal.
yeow (descending frequency from
The best frequencies to travel through the facility are between 500- 1000Hz.
The most effective alarm noises for penetrating and attracting attention are sirens and horns.
For existing sites, any new alarms shall be consistent with existing site alarms to avoid confusion.
7.1.4 Warnings devices
Hazard alerting devices should be provided to warn personnel of impending danger or existing hazards.
Multiple sensory warnings should be provided (e.g., flashing light and audible alarm) when conditions are changing and hazardous (e.g., crane movement).
Visual alarms / warning beacons (rotating or flashing lights) should also be used in conjunction with audible alarms in spaces with high ambient noise levels and/or where conditions exist which may interfere with audible alarm detection.
Locations of warning devices (such as beacons and horns) should consider access for maintenance and to ensure appropriate operational coverage should a warning device be out of service.
7.1.5 Control/Display/Alarm integration
Page 42 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
The relationship of a control to its associated display and alarm should be immediately apparent and unambiguous to the operator. The control / display relationships should be apparent through proximity, similarity of groupings, coding, framing, labelling, and similar techniques.
A control actuator and its associated display and alarm should be mounted in the same plane where practical. Controls should be located below the relevant display (preferred) or to the right (acceptable).
Layout and clearance should be such that both the display and alarm remain clearly visible to the operator whilst operating the control actuator.
Controls and displays / alarms used on identical systems located in different locations in the same compartment or in different compartments should be located in the same spatial relationship to the equipment in each compartment.
Functionally related controls and display / alarms should be located in proximity to one another and arranged in functional groups. Functional groups within a panel should be set apart by outlining with contrasting lines that completely encompass the groups. Functional groups of controls and displays / alarms should be located to provide for left-to-right (preferred) or top-to-bottom order of use, or both.
Providing the integrity of grouping by function and sequence is not compromised, the more frequently used groups and the most
Page 43 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
important groups should be located in areas of easiest visual and / or reach access.
Control-display groups required solely for maintenance purposes should be located in positions providing a lesser degree of access relative to operating groups.
Location of recurring functional groups and individual items should be similar from panel to panel.
Mirror imaged arrangements shall not be used.
Whenever possible the controls associated with a horizontal row of displays should be placed in a horizontal row directly below the displays. Avoid a horizontal row of displays / alarms associated with a vertical column of controls or vice versa.
For control actuators that cannot be located beneath or to the right of their respective displays or alarms, the actuators should be grouped in the same row arrangement as the displays or alarms.
An analogue display that must be monitored concurrently with manipulation of a related control should be located so that the operator can observe the display directly to avoid parallax error.
When the manipulation of one control requires the reading of several displays, the control should be placed as near as possible to the related displays and below the middle of the displays, but not so as to obscure the displays when manipulating the control.
Emergency displays and controls - those associated with a hazardous or potentially hazardous condition that require immediate action to
Page 44 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
prevent injury to personnel and/or damage to equipment - should be located where they can be seen and reached with minimum delay.
Display indicators should clearly and unambiguously direct and guide the appropriate control response.
The responses of a display to control setting movement should be consistent, predictable and compatible with the operator s expectations.
7.1.6 Escape and Evacuation Alarms
See Detection, communications, warnings and alarm systems in place for Emergency Escape and Evacuation shall adhere to the Escape, Evacuation and Rescue Assessment HSE-RM- ST07 (EERA studies).
7.2 Local Control and Display Panels
Clearance between cabinets and/or other equipment, to allow for door opening and any requirement for equipment withdrawal plus an additional minimum of 900mm of free space.
equivalent to prevent doors swinging closed.
Equipment arrangements should consider the weight and manual handling implications (e.g., place heavier equipment lower down in cabinets, allow access for manual handling equipment if required).
Accessibility for instruments and local control panels shall be assessed during 3D model reviews.
7.2.1.1 Additional instrumentation Requirements
Page 45 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
All information is to be presented in directly usable form; a user should not have to decode or interpret data. The operator should not be expected to perform mental calculations using the information provided.
All displays necessary to support an operator activity or sequence of activities should be grouped together.
Displays should be arranged in relation to one another according to the sequence of their use or the functional relations of the components they represent.
Displays should be arranged in sequence within functional groups, whenever possible, to provide a viewing flow from left to right (preferred, unless the local stereotype is for right to left) or top to bottom.
Primary displays, including those used frequently, that are used for obtaining precise readings or those used in emergencies, should be located within the immediately readable field-of-view. See 10.1.1.2 below.
Dual gauges providing an IN and OUT reading (e.g., suction and discharge, voltage in and out, etc.) should be arranged so the gauge with the IN reading is on the left (preferred, unless the local stereotype is for right to left) or top, and the gauge with the OUT reading is on the right (preferred) or bottom.
Methods should be provided to determine if a display circuit has failed.
Page 46 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
The absences of a signal or visual indication should not be exclusively used to denote a malfunction or out-of-tolerance condition; malfunction indicators are required.
Separate and distinct information required for operations versus maintenance should not be combined in a single display unless the information content and format are suited to both users.
Trade names, logos, equipment model, contract numbers, or any other information not directly required by the users should be avoided on the primary HMI face of display panels.
No display shall require the removal of a cover or other component to be visible, unless the display is only utilized for maintenance, and it has a clearly marked quick access door that does not require the use of tools to open.
Page 47 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Where practical, controls for similar functions should be standardized in regard to size, shape, color, location and direction of movement. However, standardization of controls is to not be applied in cases where differentiation between distinct functions is critical. In cases where separate controls serve different critical functions (e.g., start vs. stop; release vs. move) such controls should be sufficiently differentiated and instantly recognizable.
Page 48 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Controls associated with a specific display shall be located directly below the display, of the display.
Spacing between controls and/or adjacent obstructions should consider method of operation and ensure required accessibility and clearances. For example, for:
i. Single-handed finger operated toggle switches and rocker switches; the minimum separation requirement is 19 mm.
ii. Single-handed finger operated push buttons, rotary switches, and knobs; the preferred separation is 50 mm, and the minimum requirement is 25 mm.
iii. For Palm operated push buttons the preferred separation is 150 mm.
iv. For Thumb operated push buttons the preferred separation is 100mm.
Positive indication of control activation (e.g., via feel, an audible clicking noise, or a display) should be provided.
All controls that function in sequential operation necessary for a particular task or that operate together should be grouped together along with their associated displays. When several steps of a sequence are selected by one control, the steps should be arranged by order of
acceptable. Where sequential operations follow a fixed pattern, controls should be arranged to facilitate operation (such as in a fixed
ON / OFF position is not
Page 49 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
pattern left-to-right (unless local stereotype is right to left) and top- to-bottom).
Controls should be designed / located / protected so that they cannot be operated accidentally. This is critical for any control where inadvertent movement may result in injury to personnel, damage to equipment, or degradation of system functions. Transparent guards should be considered.
Any methods of protecting a control from inadvertent operation should not preclude operation within the time required. If a cover guard is used, it is to not interfere with the protected control, or adjacent controls, when in the open position.
All emergencies stop buttons should be colored red. Emergency stops should be designed / located / protected so that they cannot be operated accidentally.
Emergency stop buttons should be located such that they are easily visible and accessible from the normal operating positions and do not require the operator to enter a hazardous situation to activate. This may require additional emergency stop buttons for specific equipment.
Controls (excluding valve hand wheels) mounted on a vertical surface should be located between 1000 mm and 1650 mm above the
than 1650 mm. Critical controls should be no lower than 945 mm and no higher than 1333 mm. (Consider the anthropometric data for the
Page 50 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
workforce and adjust these dimensions if required to suit, dimensions to be agreed with COMPANY) See Figure 7-2 below.
Control panels should be located and oriented so the operator can directly view the equipment being controlled and/or monitored. Local control panels should be oriented, so the operator faces the equipment as they face the panel. The layout of the panel is to reflect the spatial arrangement and functional layout of the controlled equipment.
Where control panels are required to be remote from the equipment, the controls and displays should be mounted such that the relationship of the controls and displays matches the arrangement of the controlled equipment.
Controls should be selected, located, and oriented so that their motion is compatible with the movement of the associated display or equipment, and should match operator expectations. Table 7-1 provides general guidance only. Designers should consult an HFE specialist or their designated discipline engineer for further specific guidance as needed.
Page 51 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Page 52 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
7.3 - Instrumentation
Heavy instruments (greater than 23kg) shall be accessible by (preferably) mobile lifting equipment or permanent lifting facilities.
Instruments, junction boxes, local control panels and impulse lines shall allow sufficient working area around them to allow cleaning, set up, calibration, maintenance, rodding out and removal/replacement.
This includes any special requirements necessary for the safe handling due to very toxic substances.
Local instruments such as pressure and temperature gauges shall be mounted so they are upright.
Page 53 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Gauges and displays requiring frequent monitoring that are fitted to equipment inside acoustic enclosures shall be located outside the acoustic enclosure.
Gauges and other analog instruments shall have black text/numbers on a white background. Text shall be sized according to the requirements for visual acuity (see Visual Acuity section 10.1.1.5).
Page 54 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
The drain/vent of the Level gauges require regular draining / venting in operation and shall be routed to closed process drain / flare as necessary.
For instruments having Fire Proofing, the hand wheel for on/off or control valve shall be accessible for operation and the accessories shall be accessible using access door arrangement. These shall not compromise the quality of the fire proofing enclosure.
7.4
Control Panel Signage and labelling
See section 6.5 for general guidelines on signage and labelling, which also apply to control panels.
7.5
Human Machine Interface (HMI) Design
Page 55 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
See also HMI shall be designed based on the requirements of AGES-PH-04-001, related AGES and ADNOC Group standards together with international/ industry standards inclusive of ISO 11064-5, ASM Consortium Guidelines on Effective Console Operator HMI Design, ISO 62682, EEMUA 201, etc.
HMI Checklist is in Appendix 3.
Refer to AGES-SP-04-001: Process control system specification for details. Usually, hardwired emergency systems and annunciator panels are also provided to maintain safe state of the process, refer AGES-SP-04-003: Fire & gas specification, AGES-SP-04-004: Emergency shutdown (SIS) system specification for details.
The HMI shall be simple to learn and use. Operators have access to a large amount of plant information, but it is important they are not overloaded.
Information displayed in groups on graphics should be functionally related. Graphics shall be consistent with the actual process.
The HMI shall be designed to ensure that errors made by operators do not create a hazard. E.g., using data entry checking.
The operations team shall be actively involved in the development of the HMI
The workstations/ HMIs system response times and other performance requirements shall be as per ISO 11064-5:2008 Annex-A.
7.5.1 Display Design
7.5.1.1 Display Hierarchy
The hierarchy levels help the operator navigate through the process control displays. How the levels are configured will depend on the complexity of the process. The top level should provide key process information and emergency, alarms, plus fire and gas alarms.
Page 56 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
The second level could be the process overviews of each area, the third level could contain more detail about subsections of the plant.
Navigating between levels and from one section to another should be intuitive with minimal number of inputs from the operator. Multiple methods for navigating between different levels and screens shall be available to the operator, including menus, process overview screens, navigation targets on screens, using text input, search tools etc.
Guidelines given in AGES-PH-04-001 shall be applied for developing and organizing the hierarchical displays for workstations HMIs. Navigation among the displays shall be logical/ sequential and aid in managing the normal and abnormal situations.
7.5.1.2 Display Contents
Pop ups can be useful to provide the operator with extra information as required without cluttering up the display but should not obscure important information on the main display.
If operators will need to routinely compare information, then that information shall all be available on the same display rather than across screens, so they do not need to try and retain information. Information presented to the operator shall not require the operator to perform any mental calculations or conversions.
Trends shall indicate the normal range for the variables shown.
Color shall be used to distinguish between several variables being trended but should account for operators with impaired color vision when selecting colors. Each variable shall be labelled, including the
Page 57 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
units of measurement. There should be no more than 12 traces per trend, and the ability to distinguish between trends (other than color) by using symbols or different line types, and/or the ability to
should be used.
7.5.1.3 Display Layout
The components of each display, such as title, alarms list, navigation lists etc., shall be consistent on all displays.
Abbreviations and labels shall be standardized across the system.
Symbols shall be consistent across the system and be meaningful to the operator. The size of the symbol shall be determined by the viewing distance.
Graphical objects such as analog dials, digital counters etc. help present information in a useful way. These objects shall be consistent across the system.
Numeric Values shall only be displayed to the level of accuracy required, e.g., 75psi not 75.05psi. Numbers shall be presented horizontally and include units of measurement. For numeric values in tables, ensure that the decimal points are lined up.
7.5.1.4 Text
Text is used to identify items on screen, such as equipment names and tag numbers. A simple block font and font size shall be used. Font size shall be dependent on the viewing distance, the limit of legibility is considered to be 200x the letter height (see section 10.1.1.5). If the
Page 58 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
be large enough for the operator to be able to select it reliably.
Text shall be presented horizontally.
Text messages and labels longer than three words shall be in mixed upper and lower case for ease of reading.
AGES-PH-04-001 shall be applied for defining text information/messages used in displays. Text on displays is required to be brief and consider location and functional/contextual information.
7.5.1.5 Display Color
Color coding of data shall be consistent across the system and shall adhere to any local stereotypes.
The use of color should not be overused and should not be the primary means of coding due to possible color vision impairment. (See 10.1.1.4) Text, shape, shading etc. can all be used in addition to color.
However, flashing/blinking/animation shall be restricted to items that need to attract the operator attention and shall not be used to indicate normal operations such as an agitator moving.
Colors of routine statuses of equipment shall not detract from detection of parameters in alarm.
For the background color, white and black shall both be avoided in normal circumstance due to eye strain (note that black may be useful when operators are in a dark working environment, so their eyes do
Page 59 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
not need to adapt to large changes in light intensity. See 10.1.1.3). Ideally an off-white color such as light or mid grey should be used.
Color can be used as a secondary means to differential between identical process trains.
The choice of colors shall aid in situational awareness of the process and identify normal and abnormal conditions within the process/ process equipment.
7.5.1.6 Data Entry
Methods for reducing likelihood of error when entering data shall be used e.g., programming in acceptable ranges, using drop down menus or allowing small incremental changes.
Should any safety study (such as HAZOP) identify circumstances where incorrect data entry may result in a hazard then the design shall ensure these errors cannot be made.
7.6
Control Room Design and Layout
See Control Room checklist Appendix 4
7.7
Remote Operations
Remote HMI may need to be ruggedized/weatherproof and therefore may be nonstandard, which may impact usability. Is there any such equipment?
Operators may need to use keyboards or handheld devices whilst wearing gloves. Screens may be smaller and more difficult to read, so
Page 60 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
different graphic displays to allow remote operations maybe necessary.
Suitable task lighting shall be provided.
Audible alarms from remote HMI shall account for any increased local background noise.
Handheld devices may also be used to replace traditional paper checklists, avoiding the need to later enter data manually (and therefore reducing the potential for error). These shall be suitable for use in the applicable hazardous/non-hazardous areas (e.g. ATEX).
If an operator is regularly required to collect data that is considered important enough to require a handheld device, then an assessment shall be made whether providing permanent instrumentation instead is a better option. This
prevents operator error/omission and reduces their workload and is more robust from cyber-security aspect. In there any activity with such equipment?
8
Manual Handling and lifting requirements
See also HSE-OS-ST17 Manual Handling) & Appendix 5.
When designing and constructing machinery, the design shall meet the essential requirements for safety and health. The hazards of the machine, installations, equipment and consider these hazards related to the life cycle of the machine.
During the design a three-stage approach shall be adopted:
Page 61 of 78
Package / Area / Unit:
Item:
Vendor Name:
PO No:
Attachment 1 - HFE (Vendor) Checklist
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
POINTS TO CHECK (Categorized into main HFE Areas)
a. Avoid manual handling activities wherever possible.
b. Utilize technical aids, such as lifting equipment where manual handling activities cannot be avoided.
c. Further reduce the inherent level of risk by optimizing handling activities.
The design shall ensure that the requirements for manual lifting, pulling, pushing, and carrying of equipment are met, with respect to the biomechanical and physiological capabilities and limitations of personnel are considered.
All manual handling tasks shall have a manual task risk assessment that will be a deliverable to operations.
The risk shall be assessed and shall consider the variation of physical size (based on anthropometric data), sex, age, strength and endurance of the workforce.
Quantitative manual handling assessment by NIOSH lifting equation shall be performed when necessary, as per ADNOC standard and validation.
Load limitations for safe lifting:
Page 62 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
There is no such thing as a completely safe manual handling operations. But working within the following guidelines will likely risk the risk but does not opt out the requirement for qualitative or quantitative assessment.
(i) Use figure below to make a quick and easy assessment for weight to be lifted.
(ii) Each box contains a guideline weight for lifting and lowering in that zone.
(iii) As can be seen, the guideline weights are reduced if handling is done with arms extended,
Page 63 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
or at high or low levels, as that is where injuries are most likely to happen.
(iv) Before conducting the activity, compare it to the figure below. First, decide which box or moving the load. Then, assess the maximum weight being handled. If it is less than the guideline weight in that position as given in figure, the operation is within the weight limitations.
use the smallest guideline weight.
(vi) The guideline weights assume that the load is readily grasped with both hands and that the operation takes place in reasonable working conditions, with the lifter in a stable body position.
9
Working environment
9.1 - Noise
Maximum noise limits and safeguards shall conform to HSE-OH-ST08 Physical Health Standard. In general noise control (e.g., choosing low noise equipment) at source shall be the primary goal and noise mitigation (i.e., hearing protection) is to be adopted as the last line of defense. See Appendix 6.
The design shall ensure that essential operational audio information/communications are readily distinguishable and easily discernible with the context of the general noise environment for all credible scenarios.
This requirement includes but is not limited to:
a. Routine operational equipment checks.
b. Inter-personnel voice / radio communications.
Page 64 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
c. Critical information such as alarms and device movement warnings.
d. Alarms and warnings should be appropriate for the particular environment. All critical information, alarms and warnings should have multiple sensory indications that should at a minimum include clear visual indication in addition to audible warnings. (See section 7.1)
e. Acoustic insulation / noise enclosures create operability and maintainability issues. Where acoustic
insulation or noise enclosures are essential, they should meet the following HFE criteria:
i. Acoustic insulation should not impede access, including visual access, for routine operational checks and activities.
ii. Acoustic insulation applied to equipment or components requiring infrequent visual inspection and /or access for maintenance / replacement should be able to be easily removed, identified, and reinstalled.
HSE-OH-ST08 Physical Health Standard specifies the limit values for noise in the workplace. However lower noise levels can also cause annoyance during work, causing issues such as difficulty in concentrating etc. Noise is considered a nuisance when it interferes
nature to nuisance noise, what one worker may consider annoying may not be annoying to another.
9.1.1. Nuisance Noise
In areas such as control rooms, the operators may want to play music etc. to counteract this. If this is the case, then consideration should be
Page 65 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
given during design to installing a system that automatically cuts out the music when alarms and radio messages are received so that the alarms and messages are heard clearly without additional operator action.
Noise levels shall be limited to 85 dB (A) at 1 meter for design of silencers.
ADNOC noise exposure limits are 85 dB (A) for 8 hours TWA exposure and 140 dB (C) for impulse sound pressure level exposure shall be considered in design.
The PA system, telephone or radio communication and alarm signaling devices SPL (Sound Pressure Level) shall be at least 15 dB above the ambient noise level, or 5 dB above the maximum SPL having duration of 60 seconds to allow reliable speech as per NFPA 72.
Acoustic insulation requirements within enclosed spaces shall be specified whenever the sound pressure level exceeds the acceptable noise exposure limits, also in plant areas where (PPE) hearings protection are necessary.
Note: Such areas within the plant shall be designated by a floor
9.2. Lighting
See also General Office lighting is covered in the Occupational Health Management Standard HSE-OH-ST11.
Designers should provide project compliant lighting to ensure adequate visibility in all conditions
Page 66 of 78
Package / Area / Unit:
Item:
Vendor Name:
PO No:
Attachment 1 - HFE (Vendor) Checklist
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
POINTS TO CHECK (Categorized into main HFE Areas)
(daytime, night-time, various weather conditions, sea spray, sandstorms etc) for:
a. Access ways.
b. Level and surface changes.
c. Stairs.
d. Ladders.
e. Work Areas.
f. Bunds and Drain pans.
g. Equipment Components.
h. Connections
i. Valves
j. Local Instruments
Table 9-1 Recommended Illumination Levels for Different Types of Activities below presents ranges of illumination levels (in lux) recommended for different types of visual work activities and areas. Local task lighting should be used to provide illumination levels above 1000 lux. The average age of the workforce may be considered when determining the illumination levels to address the general decrease in visual acuity with age.
Page 67 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Illumination levels recommended for selected tasks in process areas are presented in Table 9-2 below :
Page 68 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Illumination levels should not change dramatically in adjacent areas,
change of light intensity (See section 10.1.1.3).
incident light determine how the color of the object is affected by the incident light.
The CRI quantifies how well the light source reproduces the natural color of an object and varies from 0-100. As the CRI increases, color judgement errors decrease. Light sources with a CRI below 60 should be avoided when accurate color judgement is important. Ideally a CRI of greater than 80 should be used.
Page 69 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
and make reds more vibrant. Color temperatures greater than 4000K enhance greens and blues.
Between 3000K and 4000K most colors are enhanced equally and should be used where accurate color judgement is important.
Glare should be avoided when there is direct interference with visibility and visual performance. Positioning of plant lighting should be carefully considered to ensure there is no impact of glare where operators and maintenance staff are required to read instruments etc.
Emergency lighting shall provide minimum lighting for a period of 60 minutes and considering the duration determined in EERA study to enable controlled movement of personnel should the main power supply fail for the escape route of highest platform to muster point.
Escape route drawings shall be combined with emergency lighting drawings to ensure adequacy of emergency lighting.
9.3 Vibration
See also HSE-OH-ST08 Physical Health Hazards Standards for further discussion on the effects and methods of reducing impact.
ADNOC Group and Contractors shall comply with controlling vibration at work through elimination or minimisation of exposure to all types of noise below the Action Values and Limits tabulated below. These requirements are based on current European regulations. The Action and Limit Values are tabulated in the following Table 7.3.3.
Page 70 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
9.4 Temperature
See HSE-OH-ST08 Physical Health Hazards Standard and HSE-OH-ST11 Occupational Health Management Standard.
Indoor moderate thermal environments should be designed to ISO 7730:2005.
Equipment at high or low temperatures needs to have protection to prevent injury. This includes:
a. Atmospheric vents should be located and orientated away from accessways, stairways etc. The location should consider prevailing wind conditions with respect to access ways and routine operational areas.
b. Drains, vents, bleed sampling and inspection ports etc., should be capable of operation without risk of exposing the operator to thermal hazards, preferably without the need for additional PPE.
c. Any thermal insulation or guarding shall be designed and installed such that it does not pose a risk to operators from sharp edges.
Page 71 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Is there any tasks to perform in temperature environment above 33°C? If any, complex cognitive tasks should be avoided.
The requirement for operators/maintenance staff to perform heavy physical work in a high temperature environment should be minimized by appropriate design.
Thermal PPE (e.g., gloves and thermal clothing) can protect operators against the effects of cold environments, however these can cause additional issues, such as lack of dexterity. Any tasks that require an operator or maintenance worker to work in a cold environment needs to consider the impact of cold and any additional PPE requirements. TRA shall be performed.
Appropriate design measures shall be provided to protect against injury from hot equipment with external metal or conducting parts having a surface temperature that may be hotter than 60°C in normal operations and there is risk of being touched by personnel.
Extent of personnel protection insulation shall not exceed 2m above not more than 1m away from accessible areas.
The design should not rely on personnel wearing gloves or other PPE, except for items such as handrails, which may exceed 60°C due to solar radiation, and where the use of insulation would be impractical.
9.5 Ventilation
See Indoor Air Quality Standard HSE-OH-ST12. Appendix 7 HVAC Checklist
Page 72 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Fresh air should be supplied, and stale air removed at a minimum rate of 36m3/hour per person, this can be by natural ventilation or be mechanically controlled.
Windows and skylights etc. shall be designed to ensure there is no excessive solar gain. Any equipment in the workplace shall not cause excessive heat build-up in the workplace.
Other factors that will affect the comfort of the workforce, such as draughts (air speed), vertical temperature differences, hot or cold floors and radiation asymmetry, shall also be considered. These factors should be minimized.
A Humidity level shall be maintained in the range of 30% to 60%.
Recommended temperature range shall be between 20-24°C in indoor environment.
Humidifier controls, cleanliness and operation shall be frequently checked.
Page 73 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
Indoor environments where natural ventilation is not an option, an HVAC system shall be considered satisfactory if it conforms to the following parameters:
(i) Providing a minimum fresh-air flow of 8 litres per second per person in no smoking areas and a flow rate of up to 32 litres per second per person in heavy tobacco smoking areas;
(ii) Indoor air velocities shall normally be between 0.1-0.15 m/s and up to 0.25 m/s during summer. Air flow velocities greater than 0.25 - 0.35 m/s present undesirable draughts; while velocities below 0.1 m/s render the environment stagnant;
(iii) Areas housing office equipment [e.g. photocopiers and printers], and dedicated tobacco smoking rooms shall have separate extract ventilation systems;
(iv) Air intakes for the HVAC system shall be installed at locations that avoid introducing external pollutants [e.g. particulate matter, or volatile organic compounds] into the indoor environment; and
Page 74 of 78
Package / Area / Unit:
Item:
Vendor Name:
PO No:
Attachment 1 - HFE (Vendor) Checklist
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
POINTS TO CHECK (Categorized into main HFE Areas)
(v) The HVAC system should not in itself release hazardous materials or offensive odours [e.g. caused by stale water, unclean condensers, or dusty louvers] into the indoor environment.
9.6 Weather Protection
The design shall consider any weather protection for the operators. This can be related to:
a. Platform and vessel orientation
b. Explosion Protection
c. Module layout
d. Weather cladding
to adverse weather, this should be identified and where possible the design shall include weather protection for the operator. This includes operator shelters.
In high temperature areas where physical work is regularly performed, adequate ventilation should be provided to maintain the temperature below 32°C. In other areas where there may be non-routine work conducted, space and utilities for temporary ventilation shall be provided.
10
Human reliability and performance
Refer to AGES-SP-03-004 for detailed explanations. Hereunder, only relevant requirements are integrated within the checklist. Tools are proposed to help HFE screening.
The optimal field of view, with an angle of view of 1° where objects are sharp, and detail can be seen clearly.
Page 75 of 78
Package / Area / Unit:
Item:
Vendor Name:
PO No:
Attachment 1 - HFE (Vendor) Checklist
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
POINTS TO CHECK (Categorized into main HFE Areas)
The middle field with a visual angle between 1° and 40°, where objects are not in sharp focus, but movements and strong contrasts will be noticed. The outer field with a visual angle ranging between 40° and 70°, where objects are not sharp. Objects need to be moving to be noticeable.
Objects that the operator needs to see clearly therefore must be located in their optimal field area.
10.1.1.4 Color Vision
Different lighting bright light, eyes are more sensitive to red and less sensitive to blue. In lower levels of illumination, the reverse is true. Perceived color is also dependent on the color rendering index (CRI). See 9.2.1.1 for further details. Color blindness (especially red-green) is not uncommon and affects about 8% of the male population and 1% of the female population.
information and should be used as an additional method in conjunction with other methods. Different lighting conditions affect
red and less sensitive to blue. In lower levels of illumination, the reverse is true. Perceived color is also dependent on the color rendering index (CRI). See 9.2.1.1 for further details. Color blindness (especially red-green) is not uncommon and affects about 8% of the male population and 1% of the female population.
Page 76 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
information and should be used as an additional method in conjunction with other methods.
10.1.1.5 Visual Acuity
Visual acuity needs to be considered, for instance, when designing signs on plant, specifying gauge sizes or visual displays in the control room. The required height of any text is dependent on the normal maximum viewing distance. For favorable conditions, the following formula should be used.
H=D/200
Where: H is the character height D is the distance. (the units of measurement are the same for both H and D but can be inches, millimeters etc.). Favorable conditions means that the contrast is high, (e.g., black characters on a white background), the illumination levels are optimal, without glare, the operator has sufficient time to focus on the object to be able to focus and take in detail and there no movement of the object. For less favorable conditions, the following formula should be used.
10.1.3.2 Perception
H=D/120
to respond. E.g., if an operator experiences a high number of false alarms, they then expect all following ones to be false as well. If a true
Page 77 of 78
Attachment 1 - HFE (Vendor) Checklist
Package / Area / Unit:
Item:
Vendor Name:
PO No:
POINTS TO CHECK (Categorized into main HFE Areas)
Comments / Non-Compliance (Deviation Number if any, please put NA if not applicable)
VENDOR
CONTRACTOR
Status (Open / Closed)
alarm then occurs the operator is likely to perceive it as false and ignore it. (See section 7.1). Alarm rationalization shall be conducted to limit this. Choice of equipment as switch, push button shall follow the affordance principle.
10.1.3.4 Decision making
To improve the human decision-making process for the operator the following should be considered:
a. Design in support systems to aid the operator. E.g., eliminate the need for the operator to make a manual calculation and build it into the control system, reduce the use of favor of simple descriptions.
b. Use decision tools and aids, e.g., using an expert system
together information from a number of sources to calculate and predict future outcomes, rather than the operator needed to decide what information to look for.
c. Training and simulation. This is especially useful for abnormal situations that the operator will not normally experience.
Page 78 of 78
APPENDIX 1
- STANDARD
Standard Number and Version
HSE-OH-ST11
Standard Title
Ergonomics Hazards
Completed by (Signature)
Date
Compliance
Comments
YES
NO
N/ A
- COMPLIANCE CHECK DETAILS
Completed by (Name)
Group Company
Location of check
Contractor Location (If applicable)
- CHECKLIST
Item No
Description
Section 7.1 – Ergonomics & Health Effects
Similarly Exposed Worker Groups (SEGs) who are prone to work activities with ergonomic-related risks, as well as specific job activities and tasks where ergonomic-related risks may arise have been identified
Section 7.2 – Risk Assessment
Qualitative Risk Assessments (i.e. REBA, RULA, ART) for ergonomics hazards has been performed by Competent Person
Quantitative Risk Assessments (i.e. Strain Index, Hand Activity Level) for ergonomics hazards has been performed by Competent Person
Ergonomic risk levels (Low/Medium/High Medium/High) for various work activities have been determined by SEG
Recording of ergonomic risk assessments and prioritization for dealing with high, and high-medium risks with timely schedule and responsibility of the action closure
Section 7.3 – Occupational Risk Factors Associated with Upper Extremities
Consideration of all occupational risk factors associated with upper extremities during the risk assessment
Assessment and management of the risks of WRULD as mentioned in the Standard
Section 7.4 – Occupational Risk Factors Associated with Lower Back
Consideration of all occupational risk factors associated with lower back during the risk assessment
Section 7.5 – Ergonomics in Design
CWERE self-assessment checklist for office ergonomics has been utilized as mandated in the Standard and reflected in the Group Company procedure
Maintaining the office noise levels as mandated in the Standard (i.e. 55dB(A) if task requires concentration and 60dB(A) for other tasks)
Proper illumination for the Indoor environment (i.e. General Offices, Drawing Offices, Computer Work Stations, Filing Rooms, Changing Rooms & Toilets) as mandated in the Standard
Section 7.6 – Training & Competence
General ergonomic awareness training provided to all personnel who are or may be at risk of MSD by a Competent Person
1
APPENDIX 1
- CHECKLIST
Item No
Description
Manager and Supervisor training on ergonomics has been provided to relevant personnel
Formation of ergonomics assessment team under the guidance of competent Team Leader
Appointment of Ergonomics Team Leader from ADNOC Senior Management Team
Compliance
Comments
YES
NO
N/ A
2
APPENDIX 2
- STANDARD
Standard Number and Version
AGES-PH-04-001
Standard Title
HMI Checklist
- COMPLIANCE CHECK DETAILS
Completed by (Name)
Group Company
Location of check
Contractor Location (If applicable)
- Unintentional activation and deactivation shall be prevented
Completed by (Signature)
Date
Topic
No concerns or Not Applicable
Minor concerns Major concerns
Subject to verification
Action
1.1 System design ensures operator readiness before transfer of control (e.g. pushing of two buttons simultaneously, need to have both hands on the controls, need to have eyes on the screen…)
1.2 Surprising or inexplicable operator-initiated activation/deactivation during regular use
- The system mode shall be displayed continuously
2.1 Minimum set of mode indicators present :
2.1.1 functioning properly
2.1.2 currently engaged in an automated operation mode
2.1.3 currently unavailable for automated operation
2.1.4 experiencing a malfunction
2.1.5 requesting a control transition from the automated operation system to the operator:
Indicators missing Indicators not distinguishable from each other Indicators only displayed for short periods of time Mode indication discontinued (e.g. through pop-ups)
- System state changes shall be effectively communicated
3.1 Recognizable change of pictorial indicator
3.2 Auditory / Haptic feedback
3.3 Communication of responsibility (e.g. by disclaimer)
3.4 Pop-up messages
3.5 Error messages are provided in case (e.g. failed activation)
3.6 Delayed reaction to control input displayed in HMI
- Visual interfaces used to communicate system states shall be mounted to a suitable position and distance
4.1 Visual interfaces used to communicate system states shall be mounted to a suitable position and distance
1
APPENDIX 2
4.2 High-priority information shall be presented close to operator’s expected line of sight
4.3 Important information displayed in 30° cone about normal line of sight
4.4 Safety-critical information displayed in 20° cone about normal line of sight
4.5 Peripheral displays support noticing of mode changes (e.g. movement or size of displays)
4.6 Status information mirrored on NDRT device
- HMI elements shall be grouped together according to their function to support the perception of mode indicators
5.1 Unnecessary glances to retrieve information from display (e.g. symbol and perceive accompanying text)
5.2 Indicators pertaining to the automation are grouped together
5.3 High priority messages are easily distinguished from low-priority messages
- Time-critical interactions with the system shall not afford continuous attention
6.1 Important information is displayed too shortly (few seconds)
6.2 While the operator is responsible for the DDT, sustained attention (longer than 1,5s) is needed to accomplish an interaction
- The visual interface shall have sufficient contrast in luminance and/or color between foreground and background
7.1 Sufficient color and/or luminance contrast to identify different automation modes
- Texts and Symbols shall be easily readable from the permitted seating position (Font types and size of characters)
8.1 Displayed text and symbols are big enough to be easily readable
8.2 Display resolution is good enough to be easily readable
8.3 Character width and stroke width appear to be appropriate
8.4 Text-fonts are easily readable
- Commonly accepted or standardized symbols shall be used to communicate the automation mode
9.1 Commonly accepted or standardized symbols are used
9.2 Non-standard symbols are supplemented with a text label 9.3 The symbols are representative for the responsibility of the operator (e.g. displaying hands on panel in case of a hands-on request)
- The semantic of a message shall be in accordance with its urgency
10.1 Use of notification-style to present non- critical information 10.2 Use of command-style to present non- critical information
10.3 In accordance with criticality of the situation (e.g. “caution” “danger” “warning”)
2
APPENDIX 2
- Messages shall be conveyed using the language of the users
11.1 Use of national language
11.2 Use of simple language
11.3 Avoidance of abbreviations
11.4 Displaying functionality rather than SAE/NHTSA/BASt-level
- Messages shall be as short as possible
12.1 Messages are as short as possible
12.2 Not more than four chuncks of information are displayed
- Colors shall be consistently used to code systems states (excluding white and black)
13.1 Colors are used consistently throughout an automated driving mode
13.2 Note more than five colors are used
- The colors used to communicate system states shall be in accordance with common conventions and stereotypes
14.1 Colors are in accordance with common stereotypes of the user population
Red = Imminent danger Yellow / Amber = caution Green = Hazard-free operating state
- Design for color-blindless by redundant coding and avoidance
15.1 Green / Red and Yellow / Blue combinations are avoided
15.2 Systel states are redundantly coded in a suitable way
- Auditory output shall raise the attention of the operator without startling her/him or causing pain
16.1 generic auditory output :
-
Suitable length (100-500 ms)
-
Suitable loudness (50-90 dB, shall be 15 dB above backgrd noise
-
Frequencies between 500 and 4000 Hz
16.2 Vibrotactile output :
-
Suitable length (50-200 ms)
-
Frequencies between 150 and 300 Hz
-
Comfortable stimuli 10-20 dB above threshold
- Auditory and Vibrotactile output shall be adapted to the urgency of the message
17.1 Generic auditory output :
-
Auditory output of varying urgency is distinguishably different by pulse rate, frequency or loudness
-
Low-priority information is either unobstrusive or without auditory output
17.2 Vibrotactile output :
- Vibrotactile output of varying urgency is distinguishably different by pulse rate , intensities, vibrating area etc…
3
APPENDIX 2
- Different information is coded through a variation of location and timing, not frequency and amplitude
- High priority messages shall be multimodal
18.1 High-priority information is presented in more than one modality
18.2 Auditory or vibrotactile stimuli are also visually presented
- Warning messages shall orient the user towards the source of danger
19.1 Warning messages lead to an orienting response to the source of danger, causing the operator to look in the direction of the warning
- In case of sensors failures, their consequences and required operator steps shall be displays
20.1 Unavailability of sub-systems because of sensor degradation is displayed
20.2 Required operator behaviors is displayed
20.3 Consequences of sensor degradation are displayed
General Priority Level
Displays Objects
Example
1
2
3
4
5
Emergency alarm, anacknowledged, via animation (i.e. Blinking) High Alarm, unacknowledged, via animation (i.e. Blinking) Low Alarm, unacknowledged, via animation (i.e. Blinking)
Emergency alarm, acknowledged Critical alarm, anacknowledged, via animation High Alarm, acknowledged, via animation Low Alarm, acknowledged, via animation Off-normal equipment status: controller in off-normal mode (e.g. manual) pump motor out for maintenance or point with disabled alarm
Numeric data point, point selected Numeric data point, normal / Digital data point, status normal Dynamic equipment status - motor running / not running, valve opened / closed Buttons, navigate to other schematic (3D Presentation of navigation buttons with associated displays or buttons that generate a pop-up window)
Text for equipment names, tag names, engineering units Main Process lines ( solid lines, thickness line of 2,3 and 4) Minor Process lines ( same color as main process lines, solid line, 1 pixel wide; dashed lines may create more salience when displayed with solid lines)
Background color
4
APPENDIX 3
- STANDARD
Standard Number and Version
HSE-OS-ST17
Standard Title
Manual Handling
- COMPLIANCE CHECK DETAILS
Completed by (Name)
Group Company
Location of check
Contractor Location (If applicable)
- CHECKLIST
Item No
Description
Section 7.1 – Hazardous Manual Handling
Identification of hazardous manual handling activities
Section 7.2 – Types of Manual Handling Injuries
Identification of manual handling activities that can lead to minor injuries
Identification of manual handling activities that can lead to Musculoskeletal Disorders (ULDs, LLDs and back pain & back injuries)
Section 7.3 – Hazard Identification, Risk Assessment and Control
Development of a suitable hazard identification through employee engagement/input or questionnaire, observations of tasks, review of available data and considering Task, Individual, Load, Environment and Other factors (TILEO)
Ensuring that the hazards associated with TILEO factors are identified and the risks are assessed
Ensuring that the control measures which are in place are identified
Ensuring implementation of additional controls to manage risk
Ensuring Qualitative risk assessment is done to assess whether the forces, movements and postures are undertaken in such a way that they give rise to the risk of MSD
Ensuring Quantitative risk assessment is done further for Manual handling tasks with High-Medium or High risk with the use of NIOSH Lifting Equation
Addressing of high, high-medium and medium risks by providing effective controls
Ensuring significant variation in the height of storage or working surfaces is avoided in work place
Ensuring dedicated storage areas for easier movement of loads are provided for loads with large vertical movement
Ensuring team lifting practice is in place if required
Ensuring lifting loads while seated is not in practice
Ensuring swivel chairs are used to avoid twisting during handling
Ensuring regular short breaks in the work to avoid fatigue than infrequent longer breaks are in place
Ensuring transport aids such as trolleys or barrows are used to avoid long carrying of loads with height adjustments
Completed by (Signature)
Date
Compliance
Comments
YES
NO
N/ A
1
APPENDIX 3
tasks are assigned considering
Ensuring requirements before assigning/performing handling task
the age the manual
Ensuring that loads with sharp edges are effectively packed
Ensuring that hold or cold loads are placed in an insulated and if possible it handled after allowing it to attain reasonable temperature
Ensuring that protective gloves are used while handling intrinsically unsafe loads
Ensuring individuals with health concerns are properly identified and tasks are assigned accordingly
Ensuring that ground surface are kept even and firm where routine handling of loads is carried out
Ensuring that proper cleaning up of spillages of water, oil, soap, food scraps or other materials immediately are done immediately
Ensuring PPEs are loose enough to aloe free movement of personnel without any discomfort while working
Ensuring provision and plans are available to handle big loads in smaller pieces
Ensuring that loads are handled near to the body at all times for the purpose to avoid stress in lower back
Ensuring provision is in Place to place the load in a container or sling to alleviate the problem of difficulty in grasping
Ensuring slings are available loads/shifting contents
to handle unstable
Ensuring that a practice of effective job rotation is in place in avoiding the onset of fatigue as a result of prolonged use of a particular group of muscles;
Ensuring that the immediate working space and the route to be used during movement of the load is clear when planning manual handling
Ensuring that the good standard of housekeeping maintained to limit the insufficient space related risks
is
Ensuring that the ground surface is even and firm where routine handling is done
Ensuring that the work is discontinued if weather conditions are unsuitable for execution of job
Ensuring a good standard of lighting is provided
Ensuring pregnant women are not allowed to handle/lift any heavy loads
Ensuring a practice of good coordination is there while lifting task requires two or more persons
Ensuring that a nominated person guides through the task where two or more persons are in handling simultaneously
involved
Ensuring the correct type of handling aids and equipment are provided
Ensuring planned preventive maintenance has been carried out
Ensuring tasks are matched to worker’s capability
Ensuring good communication and team work is achieved
Section 7.4 – Training & Competency
Ensuring appropriate training program shall be provided to all persons involved in handling loads manually
Ensuring that they understand basic principle of safe manual handling techniques
2
APPENDIX 3
Ensuring that they are made aware to deal with unfamiliar handling operations
Ensuring that they are given a practicable example before the execution of work
Ensuring provision of specialized training for frequent heavy or specialized (e.g. team) manual handling
3
APPENDIX 4
- STANDARD
Standard Number and Version
HSE-OH-ST08
Standard Title
Physical Health Hazards
- COMPLIANCE CHECK DETAILS
Completed by (Name)
Group Company
Location of inspection
Contractor Location (If applicable)
- CHECKLIST
Item No
Description
Section 7.1 – Overview
Completed by (Signature)
Date
Compliance
Comments
YES
NO
N/ A
Identification of workplace physical agents, potential health effects, and routes of exposure. Documentation in Health Hazard Risk Register, with appropriate health risk ratings
Section 7.2 – Noise
Identification of Noise Hazards such as Non-industrial Noise & Workplace Noise, and documentation in Health Hazard Risk Register with appropriate health risk ratings
Documented methodology in measuring workplace sound levels and reflected in Group Company procedure
relevant Implementation of equipment noise as per manufacturer’s specification
information pertaining
to
Identification of medium and high risk Similar Exposure Groups (SEGs) exposed to noise
Conduct of noise qualitative risk assessment (based on 6 x 6 OHRM matrix)
Evidence of noise quantitative risk assessment through exposure monitoring reports (i.e., area or personal exposure monitoring)
Implementation of Noise Survey (e.g.; Basic Sound Survey, Detailed Sound Survey, Engineering Noise Control Survey, Noise Survey using SLM, Personnel Noise Dosimetry) as appropriate
Implementation of compliance limit for noise as mentioned in the Standard. in Group Company Procedure.
Documentation
Implementation of noise control requirements as appropriate
Development of Noise Contour Maps as appropriate
Development of background noise level map (for Brownfield projects) by third party contractor based on theoretical surveys from potential noise readings
Conduct of baseline noise survey at rated operation of equipment
Classification of noise hazard areas (e.g., hearing protection zones) and marking the area with warning signs
Use of Class 1- sound level meters (SLM) and Class 2- General purpose sound level meters (GP-SLM), Personal Dosimeters, Acoustic Calibrator etc) as appropriate
Implementation of hearing conservation program (HCP) consisting of exposure monitoring, control of risks, provision of hearing protection and audiometric examinations
Section 7.3 – Vibration
1
APPENDIX 4
Compliance
Comments
YES
NO
N/ A
- CHECKLIST
Item No
Description
Conduct of vibration risk assessment Assessment & Quantitative Risk Assessment
i.e.; Qualitative
Implementation of vibration monitoring methodology as mentioned in the Standard (refer to Company Procedure)
Use of HSE UK hand arm vibration calculator as appropriate
Identification of the high-medium and high risk SEGs for vibration-exposed workers
Implementation of vibration control measures as appropriate
Implementation of action plan for vibration exposed workers (if any)
Assessment of the effectiveness of the action plan for vibration exposed workers (if any)
Implementation of health surveillance for employees who are regularly exposed to vibration above the exposure action value (E=2.5 m/s2) for hand-arm vibration and 0.5 m/s2 for whole body vibration
Section 7.4 – Heat Stress
Implementation of Heat Stress Site Assessment Checklist as mentioned in the Standard
Implementation of risk assessment i.e.; qualitative and quantitative risk assessment for heat stress
Implementation of heat stress measurement methodology as mentioned in the Standard (refer to Group Company Procedure)
Implementation of control strategies for reducing the risk of heat-related illnesses as mentioned in the Standard
Implementation of ADNOC Beat the Heat Urine Chart for monitoring the effectiveness of hydration programs
Section 7.5 – Cold Stress
Implementation of control measures to reduce exposure to cold stress
Section 7.6 – Radiation Protection
Identification of radiation sources and documentation in ADNOC Radioactive Register
Prioritization of radiation management activities based on the level of risk to a person’s health.
Compliance with International and Federal Legislation, including FANR requirements
Implementation of methodology for measuring Ionizing Radiation. Documentation in Group Company procedure.
Implementation of action limit for classified/unclassified employee ionizing radiation exposure
Characterization of radiation exposures that can contribute to exceedances of occupational exposure limits as per the Standard
2
APPENDIX 4
- CHECKLIST
Item No
Description
Compliance
Comments
YES
NO
N/ A
/h by Radiation Protection Officer (RPO) in appropriate Dose records (i.e., Emergency or due to Accidents, during normal work)
Investigation of any employee exposures above action level
Implementation of assessment, demarcation and monitoring of site-specific Controlled areas and supervised areas
Implementation of radiation control strategies to reduce exposure to radiation sources in the workplace. E.g. Installation of shields, etc.
Implementation of daily checks for nucleonic devices stored in temporary storage area by site RPO
Implementation of Radiation Protection management program
Updating of Radioactive Material/Equipment Register to reflect changes in the sources inventory
Development of contingency/emergency plan for work with Ionizing radiation
Implementation of review process for the contingency plan for its effectiveness
Implementation of health surveillance examination for all classified workers as per ADNOC Group Medical Fitness Guidelines
Identification of NORM sources in the facility
Implementation of NORM area classification for unclassified workers
Implementation of NORM Survey Types as mentioned in the Standard
Implementation of NORM Inspection program
Characterization of baseline levels of radiation at each facility including Naturally Occurring Radioactive Material (NORM)
Implementation of NORM management guidelines handling, storage, transportation and disposal of NORM.
for
Implementation of basic NORM contamination controls
Implementation of awareness and training for the personnel working with NORM on the associated health hazards by trained RPO
Identification of non-ionizing radiation hazards, health effects and documentation in ADNOC Health Hazard Risk Register
Implementation of methodology for measuring Non-Ionizing Radiation
Section 7.7 – Hyperbaric Pressure
Implementation of control measures for noise/fatigue under hyperbaric conditions as mentioned in the Standard
Implementation of risk assessment where there is a likelihood of an employee being exposed to hyperbaric pressures by competent person
Recording of the assessment containing a plan showing prioritized actions for dealing with the high and high-medium risk, as well as a time schedule of actions/deliverables and responsibilities for closing out the actions
3
APPENDIX 5
- STANDARD
Standard Number and Version
HSE-OH-ST12
Standard Title
Indoor Air Quality
- COMPLIANCE CHECK DETAILS
Completed by (Name)
Group Company
Location of check
Contractor Location (If applicable)
- CHECKLIST
Item No
Description
Completed by (Signature)
Date
Compliance
Comments
YES
NO
N/ A
Section 7.1 – Causes of Poor Indoor Air Quality
Identification of the causes of poor indoor air quality in case of employee manifests symptoms, employee complaints
Section 7.2 – Recognition of Agents in Indoor Environment & Health Effects
Identification of the indoor environment stressors using Appendix 8: Baseline Indoor Air Quality Audit Template
Review of the chemical components of the building materials as well as cleaning products by OH/IH SME at all phases of the building project, its operation and maintenance. Documentation in ADNOC Health Hazard Risk Register
including
Section 7.3 – Investigating Indoor Environments
Investigation of Indoor Environment as per the Logic Flow Diagram provided in the Standard
Adoption of Indoor Air Quality Investigation methodology in Group Company Procedure
Conduct of baseline assessment if indoor air quality testing has not been performed; or routine monitoring of indoor air quality parameters depending on risk level using Appendix 6: Indoor Air Quality Measurement Report Template
Communication of the results and the controls to ADNOC Group employees and contractors
Section 7.4 – Evaluation of Indoor Air Quality Parameters
Implementation of the guideline values for general indoor environment and documentation in Group Company procedure
Qualitative and Quantitative Risk Level Evaluation of Indoor Air Quality Parameters and documentation in ADNOC Health Hazard Risk Register
Section 7.5 – Controlling the Indoor Environment
Implementation of applicable control measures controlling indoor air contaminants
for
Evaluation of the effectiveness of existing HVAC Systems to maintain the comfort standards as mentioned in the Standard using Appendix 7: HVAC Checklist
Maintenance of the recommended indoor temperature range (20-24°C) as mentioned in the Standard
Checking of humidifier controls, cleanliness and operation to maintain the recommended indoor humidity level in the range of 30% - 60% as mentioned in the Standard
Implementation of guidelines for the prevention and control of moulds in buildings as mentioned in the Standard
Section 7.6 – Maintenance of the Indoor Environment
1
APPENDIX 5
Compliance
Comments
YES
NO
N/ A
- CHECKLIST
Item No
Description
Implementation of Planned Preventative Maintenance (PPM) programmes (e.g., HVAC systems) for controlling the indoor potential symptoms and complaints with poor environments. Appendix 7 HVAC Checklist to be used as guidance.
Implementation of cleaning methods in building, as well as determination of appropriate frequency and materials used as mentioned in the Standard
Implementation of measures to minimize microbiological contamination as mentioned in the Standard
Implementation of mitigative measures to reduce exposure to radon gas, if applicable
Installation of mitigation systems by experienced contractors to reduce exposure to radon gas, if applicable