Infinity

Not logged in
Home

❯

Reference Examples

❯

Q 32859 NMDC Ruwais

❯

RFQ Files

❯

RLNG 000 PR PID 0004_0B

1

2

3

4

5

6

7

8

9

10

11

12

13

SIGNAL SYMBOLS

MEASUREMENT ELEMENTS

RELIEF VALVES

IDENTIFICATION LETTERS OR INSTRUMENT FUNCTIONS

NOTE 2

INSTRUMENT CONNECTION TO PROCESS

GENERAL SYMBOL

XXX

(1)

(2)

(3)

PSV : PRESSURE RELIEF VALVE

FIRST-LETTER

SUCCEEDING LETTERS

 MEASURED OR

INITIATING VARIABLE

MODIFIER

 READOUT OR

PASSIVE FUNCTION

OUTPUT FUNCTION

MODIFIER

A

B

C

D

E

F

G

H

I

J

M

S

S

M

S

S

R O F Y L P P A L L A H S 6 4 1

2 2 N O C

:

O N T N E M E E R G A

/

T C A R T N O C F O S M R E T E H T

.

I

Y T R A P D R H T Y N A O T T N E M U C O D S H T F O E R U S O L C S D Y N A

I

I

ELECTRICAL SIGNAL

SYSTEM LINK (SOFTWARE OR DATA LINK)

PNEUMATIC LINE

CAPILLARY TUBING

HYDRAULIC SIGNAL

INSTRUMENT VALVE SYMBOLS

NOTES 1,3

SPRING DIAPHRAGM ACTUATED VALVE

SPRING DIAPHRAGM ACTUATED VALVE WITH HANDWHEEL

ANGLE CONTROL VALVE

THREE-WAY CONTROL VALVE

LEVEL SYMBOLS

XXX

PRESSURE SYMBOLS

LEVEL ELEMENT XXX DENOTES:

CAP = CAPACITANCE DIS = DISPLACER DP = DIFFERENTIAL PRESSURE GWR = GUIDED WAVE RADAR MG = MAGNETIC RAD = RADAR RES = RESISTANCE US = ULTRASONIC VIB = VIBRATION

XXX

(2)

(3)

XXX (1)

P

NOTE 4

PILOT OPERATED PRESSURE RELIEF VALVE

XXX

(1)

(2)

(4)

(4)

XXX

(1)

PRESSURE AND VACUUM RELIEF VALVE

VACUUM BREAKER

PRESSURE TAP

DIFFERENTIAL PRESSURE TAPS

TEMPERATURE SYMBOLS

NOTE 8

0B

SKIN

(2)

XXX

(1)

RUPTURE DISC FOR PRESSURE OR VACUUM RELIEF

SELF ACTIVATED BACK PRESSURE REDUCING REGULATOR (INTERNAL SENSING)

SURFACE MEASURING POINT

SELF ACTIVATED BACK PRESSURE REDUCING REGULATOR (EXTERNAL SENSING)

SELF ACTIVATED PRESSURE REDUCING REGULATOR (INTERNAL SENSING)

INTRUSIVE MEASURING POINT

FLOW SYMBOLS

SELF ACTIVATED PRESSURE REDUCING REGULATOR (EXTERNAL SENSING)

PISTON ACTUATED VALVE

PISTON ACTUATED VALVE WITH HANDWHEEL

MOTOR OPERATED VALVE

TWO-WAY SOLENOID VALVE

FI

RO

RO

SENSOR

THREE-WAY SOLENOID VALVE

S

SENSOR TYPE

FOUR-WAY SOLENOID VALVE

ORIFICE PLATE

ACTUATOR SYMBOLS

AVERAGING PITOT TUBE

SPRING DIAPHRAGM ACTUATOR

TURBINE OR PROPELLER TYPE

SPRING DIAPHRAGM ACTUATOR WITH HANDWHEEL

PRESSURE BALANCED DIAPHRAGM ACTUATOR

VORTEX

M

MAGNETIC

TM

THERMAL MASS

SINGLE OR DOUBLE ACTING CYLINDER PISTON (PNEUMATIC)

POSITIVE DISPLACEMENT TYPE

MOTOR OPERATED ACTUATOR

HAND ACTUATOR

SINGLE SOLENOID ACTUATOR

SINGLE SOLENOID ACTUATOR WITH MANUAL RESET

CORIOLIS TYPE

ULTRASONIC IN LINE

VENTURI TUBE

FLOW NOZZLE

INSTRUMENTATION VENDOR BREAK

BV

R

1

XXX:

PSV, PVV, PSE OR TSV

(1)

(2)

(3)

SEQUENTIAL NUMBER

SET PRESSURE (BARG)

DESCRIPTION: - INLET ORIFICE DIAMETER - ORIFICE LETTER - OUTLET ORIFICE DIAMETER

(4)

VACUUM SETTING (BARG)

FUNCTION SYMBOLS

NOTE 1

ROTAMETER

FUNCTION

RESTRICTION ORIFICE NOTE 6

SPECIAL RESTRICTION ORIFICE WITH NOISE ATTENUATION NOTE 6

UNIT NUMBER

NOTE 5

HIGH HIGH ALARM OR EMERGENCY ACTION

ZZZ

XXXXXX

YYYY(ZZ)

HH H

L LL

HIGH ALARM

LOW ALARM

INSTRUMENT NUMBER

NOTE 2

LOW LOW ALARM OR EMERGENCY ACTION

NOTE 7

NOTE 7

XXX NOTE 9

FIELD MOUNTED INSTRUMENT

INSTRUMENT MOUNTED ON CENTRAL CONTROL ROOM PANEL OR ANALYSER SHELTER OR IES.

0B

0B

INSTRUMENT FUNCTION MOUNTED ON LOCAL PANEL

COMPUTER FUNCTION ( PRIMARY LOCATION )

INSTRUMENT WITH DUAL FUNCTION OR SERVICE

SHARED DISPLAY, SHARED CONTROL ACCESSIBLE TO OPERATOR THROUGH DCS CONSOLE

SHARED DISPLAY, SHARED CONTROL FUNCTION ACCESSIBLE TO OPERATOR THROUGH PACKAGE PLC (SUPPLIED BY VENDOR)

SAFETY OR LOGIC SYSTEM WITH XX : US FOR CONTROL LOGIC AND UZ FOR SAFETY LOGIC ZZZ : DCS,SIS,FGS,MMS

SAFETY OR LOGIC THROUGH PACKAGE PLC (SUPPLIED BY VENDOR) WITH XX : US FOR CONTROL LOGIC AND UZ FOR SAFETY LOGIC ZZZ : PLC,SPLC,CCS,TGS,MMS

ZZZ

0B

ZZZ

MISCELLANEOUS

OPTICAL AUDIBLE ALARM

OPTICAL SIGNAL

PUSH BUTTON

PRESSURE POINT

XX

XX

R

R

PP

A

B

ANALYSIS

BURNER FLAME

BD

BLOWDOWN

C

D

E

CONDUCTIVITY (ELECTRICAL)

DENSITY (MASS) OR SPECIFIC GRAVITY

VOLTAGE (EMF)

ESD

EMERGENCY SHUTDOWN

F

G

H

I

J

K

L

M

FLOW RATE

GAGING (DIMENSIONAL)

HAND (MANUALLY INITIATED)

CURRENT (ELECTRICAL)

POWER

TIME OR TIME SCHEDULE, KEYPHASOR

LEVEL

MOISTURE ,HUMIDITY OR MOTOR LOOP

MO

MOTOR OPERATED

ALARM

USER’S CHOICE

USER’S CHOICE

USER’S CHOICE

CONTROL

DIFFERENTIAL

EMERGENCY

RATIO (FRACTION)

SCAN

SENSOR (PRIMARY ELEMENT)

GLASS,GAUGE

INDICATE

CONTROL STATION

LIGHT(PILOT),STATUS

HIGH

LOW

MIDDLE OR INTERMEDIATE

O

P

Q

R

S

USER’S CHOICE

PRESSURE OR VACUUM

QUANTITY, EVENT OR FIRE & GAS DETECTION

RADIOACTIVITY OR RESTRICTION, RUNNING

INTEGRATE OR TOTALIZE

  ORIFICE

(RESTRICTION)

POINT (TEST CONNECTION) , PROBE

RECORD OR PRINT

SPEED OR FREQUENCY

SAFETY

SWITCH

SD

SHUT DOWN

T

U

V

W

X

Y

Z

TEMPERATURE

MULTIVARIABLE

VIBRATION

WEIGHT OR FORCE

ON/OFF

USER’S CHOICE

POSITION

FOR SIS IDENTIFIER

MULTIFUNCTION

WELL

TRANSMIT

MULTIFUNCTION

VALVE, DAMPER OR LOUVER

MULTIFUNCTION

UNCLASSIFIED

UNCLASSIFIED

UNCLASSIFIED

RELAY, COMPUTEOR SOLENOID DRIVER, ACTUATE, UNCLASSIFIED FINAL CONTROL ELEMENT OR SAFETY RELATED INSTRUMENT

VALVES DESIGNATION

NOTE 2

BDV DV ESDV FV/HV/LV/PV/TV MOV SDV ASV XV

BLOWDOWN VALVE DELUGE VALVE EMERGENCY SHUTDOWN VALVE ANALOG OR ON/OFF CONTROL VALVES MOTOR OPERATED VALVE SHUTDOWN VALVE ANTI SURGE VALVE ON/OFF VALVE

FUNCTION BLOCKS

REFER TO LIST BELOW FOR INDICATION

DESIGNATION

SIGNAL

14

NOTES:

15

16

FUNCTION SYMBOLS ARE BASED ON ANSI/ISA-S5.1. FUNCTION LABELS AND IDENTIFICATION ARE BASED ON DOCUMENT: N° RLNG-000-IC-PP-0001(INSTRUMENT & CONTROL NUMBERING PROCEDURE). TYPE OF VALVE BODY FOLLOWING SELECTION CRITERIA. REMOTE SENSING LINE (IF REQUIRED). ALL INSTRUMENT TAGS ARE PRECEDED BY THE UNIT NUMBER (SHOWN ON PID BY GENERAL NOTE). UNIT NUMBER WILL BE SHOWN ON INSTRUMENT TAGS, ONLY IN CASE OF UNIT NUMBER IS DIFFERENT OF PID UNIT NUMBER. A STRAIGHT RUN OF 10 HOLE DIAMETERS IS REQUIRED AFTER ANY R.O. PLATE OR AFTER THE LAST R.O. IN MULTIPLATE INSTALLATION. WHERE THE HOLD SIZE IS 10% N.P.S. AN ELBOW MAY BE INSTALLED IMMEDIATELY DOWNSTREAM. FOR ON-LINE ANALYSER AND TRANSMITTER, THE TYPE OF ANALYSIS IS DEFINED OUTSIDE THE SYMBOL: GC: GAS CHROMATOGRAPH O2: OXYGEN ANALYSER FID: FLAME IONISATION DETECTION ANALYSER H2O: MOISTURE ANALYSER FREE CL2: FREE CHLORINE ANALYSER

ALL TEMPERATURE ELEMENT WILL BE RTD TYPE UNLESS IDENTIFIED AS TERMOCOUPLE (TC) TYPE ON P&ID. FIELD INSTRUMENT LOCATION SHALL BE MENTIONED IN P&ID WITH BUILDING TAG.

0B

A

B

C

D

E

F

G

SUM/ADD

DIVIDE/RATIO

X

MULTIPLY

HIGH SELECTOR

LOW SELECTOR

DIFFERENCE

INPUT/OUTPUT THE FOLLOWING:

n

AVERAGE

INTEGRAL

n

ROOT EXTRACT

M

K

-K

nn

X X

f(x) f(x)

MIDDLE SIGNAL SELECT

PROPORTIONAL

REVERSE PROPORTIONAL

HIGH LIMITER

LOW LIMITER

EXPONENTIAL

VARIABLE FUNCTION (PRESSURE, TEMPERATURE…)

POSITIVE BIAS

NEGATIVE BIAS

ABBREVIATIONS

A/M ASC

ASD BTEX BV C

CCS DCS ESD

FGS GC HHV IES IGV LCP

AUTO/MAN ANTI-SURGE CONTROL SYSTEM

0B

0B

ADJUSTABLE SPEED DRIVE BENZENE TOLUENE XYLENE ANALYSIS BY VENDOR CLOSE

COMPRESSOR CONTROL SYSTEM DISTRIBUTED CONTROL SYSTEM EMERGENCY SHUTDOWN

FIRE AND GAS SYSTEM CHROMATOGRAPHY HIGHER HEATING VALUE INSTRUMENTED EQUIPMENT SHELTER INLET GUIDE VANE LOCAL CONTROL PANEL

0B

LOR MCC MMS MW O PLC

PST PV RTD

S/D

SCS SIS SK

SP

LOCAL OFF REMOTE MOTOR CONTROL CENTER MACHINE MONITORING SYSTEM MOLECULAR WEIGHT OPEN PROGRAMMABLE LOGIC CONTROLLER

0B

PARTIAL STROKE TEST PROCESS VARIABLE RESISTANCE TEMPERATURE DEVICE

SHUTDOWN

0B

SPCS

SPLC

TC TGS TSO UCP VFD XOOY

SAMPLE CONDITIONING SYSTEM SAFETY INSTRUMENTED SYSTEM SKIN

SET POINT

A D E I H O P R MV

ANALOG DIGITAL VOLTAGE CURRENT HYDRAULIC ELECTROMAGNETIC PNEUMATIC RESISTANCE MILLIVOLT

0B

0A

0

12-Feb-2025

18-Oct-2024

05-Jul-2024

REV

DATE

SCALE:

DRAWN:

IFD - Issued for Design

VCH

AK/SB/JGO

ADE

IFH - ISSUED FOR HAZOP

VCH

AK/SB/JGO

ADE

ICR - ISSUED FOR CLIENT REVIEW

VCH

AK/SB/JGO

ADE

DESCRIPTION

CHKD:

DRAWN

CHKD

APPRD

APPRD:

NONE

VCH

AK/SB/JGO

ADE

H

CONTRACTOR

PROJECT TITLE

SAMPLE PRE CONDITIONING SYSTEM

SAFETY PROGRAMMABLE LOGIC CONTROLLER

THERMOCOUPLE TANK GAUGING SYSTEM TIGHT SHUT-OFF UNIT CONTROL PANEL (PLC PACKAGE) VARIABLE FREQUENCY DRIVE X OUT OF Y VOTING SYSTEM

RUWAIS LNG PROJECT

DRAWING TITLE

PIPING & INSTRUMENTATION DIAGRAM UNIT 000 GENERAL INSTRUMENTATION SYMBOLS

UNIT:

000 CONTR. PROJ. No.

PLANT:

RUWAIS

215122C

DOC. CLASS:

1.5 CONT. DWG. No.:

DOC. CAT:

2

215122C-000-PID-0090-0004

ADNOC GAS AGREEMENT No.

4700022871

OC DWG. No.:

ADNOC GAS PROJ. No.

ADNOC GAS DWG. No.

22-146

RLNG-000-PR-PID-0004

SHEET

REV.

0B 01/01 SHEET SIZE : A1

I

J

i

I

d p . B 0 _ 4 0 0 0

D P R P

0 0 0

G N L R

: .

O N D A C

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Project: Q-32859 - NMDC - Ruwais Folder: RFQ Files


Loading authentication...

Graph View

Backlinks

  • 00 Index

Created with Infinity Constructor © 2025

  • Elynox | Go Further