Infinity

Not logged in
Home

❯

Reference Examples

❯

Q 32859 NMDC Ruwais

❯

RFQ Files

❯

RLNG 020 HS DWG 8840_0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

PLANT NORTH 0°

TRUE NORTH 0°

P R E V AILIN DIR G WIN E CTIO

D

N

30°

N

A

B

C

D

E

F

G

H

I

J

K

L

UTM COORDINATES E. 668742.943 2671135.627

: : : :

… .

N N E E

2671155 UTM COORDINATES 668742 UTM COORDINATES 2671155 668742

7 3 7 3 4 2 4 2 .9 .6 .9 .6

80420 80420

℄ OF 14M ROAD

42000

107580

100000

CONTINUATION HAZARDOUS AREA CLASSIFICATION DRAWING

  • OFFSITE NORTH RLNG-000-HS-DWG-8842

UTM COORDINATES E. 669072.943 N. 2671135.627

1 0 3 5

G W D S H

7 7 0

G N L R R E T A W E R F

I

I

1 0 3 5

G W D S H

4 8 0

G N L R N O T A T S B U S L A C R T C E L E N A M

I

I

0 0 5 1 9

I

I

I

I

G N W A R D N O T A C F S S A L C A E R A S U O D R A Z A H N O T A U N T N O C

I

I

0 0 5 5 8

MATCH LINE N. 1475.000

I

I

I

I

G N W A R D N O T A C F S S A L C A E R A S U O D R A Z A H N O T A U N T N O C

I

I

0 0 0 6 0 1

UTM COORDINATES E. 668742.943 N. 2670852.627

℄ OF 4.8M ROAD

086-P-204A/B 086-U-204 NOTE 2 R=1.5M

086-U-207 NOTE 3

R=1.5M

D A O R M 8 4 F O ℄

.

R=3.0M

R=15.0M

D A O R M 8 4 F O ℄

.

FGL +100.000m

AS-03 HOLD 2

R1=3.0M

086-P-201A/B 086-U-201

DROP ZONE PLTF TOS EL. +115.000

R1=3.0M

R1=3.0M

077-HX-001

R1=1.5M

077-DS-001

NOTE 5

NOTE 1

G30-PR-001

G30-PR-002

G30-PR-003

G30-PR-004

G30-PR-005

4 0 0

R P

1 1 D

PLTF TOS EL.+111.000

R1=3.0M

DROP ZONE

PLTF TOS EL. +119.500

R1=1.5M

R1=3.0M

℄ OF 8M ROAD

R1=3.0M

CRANE PARKING

R=0.5M

PLTF TOS EL.+114.000

PLTF TOS EL.+117.500

7 0 0

R P

1 1 D

DROP ZONE

℄ OF 8M ROAD

CRANE PARKING

D11-PR-002

M R A T V A D

I

D11-PR-003

D11-PR-005

DAVIT ARM

D11-PR-006

DROP ZONE

1 0 0

R P

1 1 D

PLTF TOS EL.+119.500

R=0.5M

R=0.5M

D A O R M 4 1 F O ℄

A 1 0 0

P

0 2 0

B 1 0 0

P

0 2 0

C 1 0 0

P

0 2 0

D 1 0 0

P

0 2 0

020-T-001-STR-001 IN-TANK PUMPS PLATFORM

PLTF TOS EL.+152.910

℄ OF 8M ROAD

020-T-001

℄ OF 4.8M ROAD

020-T-001-STR-002 PSV PLATFORM

PLTF TOS EL.+145.000

NOTE 4

R=4.5M

℄ OF 14M ROAD

CONTINUATION HAZARDOUS AREA CLASSIFICATION DRAWING

  • TRAIN 1 RLNG-111-HS-DWG-0301

R1=3.0M

R1=3.0M

R1=3.0M

8 0 0

R P

1 1 D

9 0 0

R P

1 1 D

0 1 0

R P

1 1 D

1 1 0

R P

1 1 D

2 1 0

R P

1 1 D

NOTE 5

83000

76000

6000

76000

MATCH LINE N. 1316.300

R1=3.0M

A 2 0 0

P

0 2 0

B 2 0 0

P

0 2 0

C 2 0 0

P

0 2 0

D 2 0 0

P

0 2 0

020-T-002-STR-001 IN-TANK PUMPS PLATFORM

PLTF TOS EL.+152.910

020-T-002

℄ OF 8M ROAD

NOTE B

D A O R M 4 1 F O ℄

020-T-002-STR-002

PSV PLATFORM

PLTF TOS EL.+145.000

NOTE 4

℄ OF 4.8M ROAD

R=4.5M

0 0 0 4 5

0 0 0 9

0 0 5 8 2

0 0 5 5 8

0 0 0 6 0 1

9 3 8 8

G W D S H

0 6 0

G N L R E R A L F & R O S S E R P M O C G O B

I

I

I

I

G N W A R D N O T A C F S S A L C A E R A S U O D R A Z A H N O T A U N T N O C

I

I

E N I L H C T A M

0 0 5 . 2 8 5 2

.

E

CONTINUATION HAZARDOUS AREA CLASSIFICATION DRAWING - TRAIN 2 RLNG-211-HS-DWG-0301

UTM COORDINATES E. 669072.943 N. 2670852.627

89000

NOT TO BE USED AS PLOT PLAN

0

10

20

30

40

50

60M

SCALE 1 : 600

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

EQUIPMENT LIST

ITEM NO.

DESCRIPTION

020-P-001 A/B/C/D

LNG IN-TANK PUMPS (TANK 1)

020-P-002 A/B/C/D

LNG IN-TANK PUMPS (TANK 2)

086-P-201A/B

LNG IMPOUNDMENT BASIN PUMPS - LNG STORAGE

020-T-001

020-T-002

086-U-201

LNG TANK 1

LNG TANK 2

LNG IMPOUNDMENT BASIN - LNG STORAGE

086-P-204A/B

FIRST FLUSH BASIN PUMP - LNG STORAGE

086-U-204

086-U-207

FIRST FLUSH BASIN - LNG STORAGE

OILY WATER AOC STORMCEPTOR - LNG STORAGE

077-HX-001

HI-EX FOAM DELUGE VALVE SKID

AS-03

077-DS-001

LNG EXPORT-ANALYZER SHELTER

DELUGE SKID FOR TANK PUMP PLATFORM

KEY PLAN

X 2

Y 2

2Z

6 8

85

4 8

2U

V 2

W 2

3 8

2 8

1 8

R 2

2S

T 2

80

9 7

78

N 2

2P

Q 2

77

6 7

75

7 1

6 1

5 1

14

E

I

F

I

6

I

v 2

w 2

4 7

73

2 7

I5

IG

H

I

2s

t

2

u 2

4

I

C 2

19

8 1

2m

2n

p 2

q 2

r 2

1 7

0 7

69

B 2

A 2

L P

PM

20

68

7 6

65

64

3 6

2 6

G P

H P

J P

61

X X 2

0 6

9 5

K P

f

2

2g

2h

j

2

k 2

8 5

57

6 5

F F 2

a 2

b 2

2c

d 2

e 2

K 2

2L

M 2

5 5

4 5

53

2G

H 2

J 2

2 5

1 5

0 5

49

8 4

47

D 2

E 2

2F

6 4

45

2A

4 4

B 2

C 2

1X

Y 1

Z 1

3 4

42

1 4

U 1

V 1

1W

40

9 3

8 3

7 3

6 3

35

R 1

S 1

T 1

4 3

3 3

2 3

N 1

1P

Q 1

t

1

s 1

47 70

1u

1v

1w

211 470 94 47 39 5 9 9 3 8 1 3

157

29

0 3

1 3

WALKWAY TYPE-4

D R A U E G P O R

Y T E F A S

HANDRAIL

A

I

IB

I1

2

I

C

I

ID

8 2

3

I

BERTHING LINE

80

m 1

1n

E

G LIN HIN T R E B

p 1

WALKWAY

4

E P Y T

1q

51 7 3 5 8 9313 9 9 8 157 47

7 2

6 2

r 1

UP

423 470

D R A U E G P O R

SAFETY

HANDRAIL

80

B 1

A 1

C 1

2 1

PE

PF

PG.

3 1

1E

D 1

9

8

11

10

7

6

5

4

3

2

1

PLANT NORTH 0° TRUE NORTH 0°

N

PREVAILING WIND DIRECTION

THIS DRAWING

j

2

0111

1f

g 1

80 47 70 78470 176 98 20 1 5 5313 S 18 9 8 6 3 0 8

PC

PB

PD

Y T E F A

17

8 1

h 1

k 1

1

P U

6 1

D R A U E G P O R

HANDRAIL

A P

BERTHING LINE

4

E P Y Y T A W K L A W

BERTHING LINE

137 8047 157 188 599878470 313 98 59 39

58

Double QRH (2x1500kN.)

FENDER SCN-1600

D R A U E G P O R

Y A W TYPE-4 K L A W

HANDRAIL SAFETY

1b

14

a 1

13

5 1

d 1

e 1

c 1

3

E P Y

WALKWAY T

2 1

11

0 1

1K

L 1

M 1

9 0

08

7 0

G 1

1H

J 1

06

5 0

4 0

D 1

1F

E 1

03

2 0

1 0

49

1A

B 1

C 1

GENERAL NOTES

A. B.

C.

D.

E.

F.

ALL DIMENSIONS ARE IN MILLIMETER UNLESS NOTED OTHERWISE. HAZARDOUS AREA DRAWING IS BASED ON EI15 CODE. IN ADDITION, EXTENT OF LFL CONSEQUENCE CONTOUR FROM 25 MM LEAK SIZE OR LFL CONTOUR FOR 1E-04/YR, WHICHEVER IS HIGHER, SHALL BE USED TO DEFINE THE EXTENT OF PROCESS AREA BOUNDARY IN TERMS OF HAZARDOUS AREA CLASSIFICATION. ALL OUTDOOR EQUIPMENT EXCEPT TRANSFORMERS AND COMPRESSOR E-HOUSE HVAC EQUIPMENT LOCATED WITHIN PROCESS AREA DEFINED ABOVE SHALL BE RATED AS MINIMUM ZONE 2, AND ANY OF THESE EQUIPMENT THAT ARE INTENDED TO BE OPERATED DURING EMERGENCY SHALL BE RATED AS MINIMUM ZONE 1. IN CASE OF FIRE AND GAS RELEASE IN PROCESS AREA, ALL EQUIPMENT NOT SUITABLE FOR ZONE 1 WILL BE ELECTRICALLY ISOLATED. IN ADDITION, IN CASE OF CONFIRMED GAS RELEASE, UNCLASSIFIED EQUIPMENT LOCATED WITHIN THE EXTENT OF 0.5 LFL CONSEQUENCE CONTOUR BASED ON 25 MM LEAK SCENARIO SHALL BE DE-ENERGIZED. ALL INSTRUMENT EQUIPMENT AND BULKS LOCATED IN PROCESS AND UTILITY AREAS OUTSIDE OF PRESSURIZED EQUIPMENT BUILDINGS SHALL BE RATED FOR ZONE 1, GAS GROUP IIB AND TEMPERATURE CLASS T3 AS MINIMUM. FOR ALL THE RATED EQUIPMENT, MINIMUM GAS GROUP OF IIB AND TEMPERATURE CLASS OF T3 SHALL BE CONSIDERED.

NOTES

IMPOUNDING BASIN IS CONSIDERED AS SECONDARY GRADE RELEASE, WITH ZONE 1 INSIDE THE BASIN. IN ADDITION, FOR ZONE 2, A HORIZONTAL EXTENT OF 15 M AND A VERTICAL EXTENT OF 3 M AROUND THE BASIN SHALL BE CONSIDERED. CLASSIFICATION INSIDE FIRST FLUSH BASIN SHALL BE CONSIDERED AS ZONE 0. ZONE 1 IS CONSIDERED UP TO 1.5 M FROM THE BASIN AND ZONE 2 UP TO 3.0 M. CLASSIFICATION INSIDE OILY WATER AOC STORMCEPTOR SHALL BE CONSIDERED AS ZONE 0. ZONE 2 IS CONSIDERED UP TO 1.5 M FROM THE BASIN. ZONE 1 IS CONSIDERED AROUND 1.5 M FROM THE RELIEF VALVE OUTLET. NO SOURCE OF RELEASE (I.E. FLANGES, VALVES) SHALL BE INSTALLED ON THE BRIDGE ABOVE ROAD.

HOLDS

LFL CONTOURS TO BE CONFIRMED. HAZARDOUS AREA CLASSIFICATION FOR ANALYZER SHELTER.

SYMBOL AND LEGEND

SYMBOL

DESCRIPTION

ZONE 0, GAS GROUP IIB, TEMPERATURE CLASS T3

ZONE 1, GAS GROUP IIB, TEMPERATURE CLASS T3

ZONE 2, GAS GROUP IIB, TEMPERATURE CLASS T3

PROCESS AREA BOUNDARY IN TERMS OF HAZARDOUS AREA CLASSIFICATION

0.5 LFL CONSEQUENCE CONTOUR FROM 25 MM LEAK

RLNG-000-HS-DWG-0301

HAZARDUOUS AREA CLASSIFICATION DRAWING - KEY PLAN

RLNG-111-HS-DWG-0301

HAZARDOUS AREA CLASSIFICATION DRAWING -TRAIN 1

RLNG-211-HS-DWG-0301

HAZARDOUS AREA CLASSIFICATION DRAWING -TRAIN 2

RLNG-084-HS-DWG-5301

RLNG-077-HS-DWG-5301

RLNG-000-HS-DWG-8842

RLNG-060-HS-DWG-8839

HAZARDOUS AREA CLASSIFICATION DRAWING -MAIN ELECTRICAL SUBSTATION HAZARDOUS AREA CLASSIFICATION DRAWING -FIRE WATER HAZARDOUS AREA CLASSIFICATION DRAWING -OFFSITE NORTH HAZARDOUS AREA CLASSIFICATION DRAWING -BOG COMPRESSOR & FLARE

RLNG-D11-PI-DWG-8000

UNIT PLOT PLAN LNG STORAGE TANK 1 & 2

RLNG-000-HS-NM-0301

HAZARDOUS AREA CLASSIFICATION SCHEDULE

RLNG-000-HS-PP-0301

HAZARDOUS AREA CLASSIFICATION PHILOSOPHY

REFERENCE DOCUMENTS

0

19-Dec-2024

ICR-ISSUED FOR CLIENT REVIEW

TV

AKM/DS JMR/MV

REV

DATE

SCALE:

DRAWN:

DESCRIPTION

CHKD:

DRAWN

CHKD

APPRD

APPRD:

1:600

TV

AKM/DS

JMR/MV

ADNOC Gas

CONTRACTOR

PROJECT TITLE

DRAWING TITLE

RUWAIS LNG PROJECT

HAZARDOUS AREA CLASSIFICATION DRAWING LNG STORAGE TANK AREA

A

B

C

D

E

F

G

H

I

J

K

L

UNIT:

020

PLANT:

RUWAIS

DOC. CLASS:

CONTR. PROJ. No.

215122C

CONT. DWG. No.:

ADNOC GAS AGREEMENT No.

4700022871

OC DWG. No.:

DOC. CAT:

2 215122C-020-DW-1920-8840

ADNOC GAS PROJ. No. 22-146

ADNOC GAS DWG. No.

RLNG-020-HS-DWG-8840 17

16

SHEET

REV.

01/01

0

SHEET SIZE : A0

G W D . 0 _ 0 4 8 8

G W D S H

0 2 0

G N L R

: .

O N D A C

0 . 0 °

Project: Q-32859 - NMDC - Ruwais Folder: RFQ Files


Loading authentication...

Graph View

Backlinks

  • 00 Index

Created with Infinity Constructor © 2025

  • Elynox | Go Further