SR No.

MISC. ITEM

SS-05

IES-03

DESCRIPTION

BOG SUBSTATION

LNG STORAGE & BOG COMPRESSION INSTRUMENT EQUIPMENT SHELTER

SS05-TR-C-001A

11kV/6.9kV, 11/13.75 MVA, POWER TRANSFORMER A

SS05-TR-C-001B

11kV/6.9kV, 11/13.75 MVA, POWER TRANSFORMER B

SS05-TR-A-001A

SS05-TR-A-001B

088-EG-201

SS05-TR-D-001

077-DS-002

132kV/11.5kV, 55/68.75 MVA, POWER TRANSFORMER A

132kV/11.5kV, 55/68.75 MVA, POWER TRANSFORMER B

EMERGENCY DIESEL GENERATOR (BOG SUBSTATION)

6.6kV/720V, 1250 kVA, DISTRIBUTION TRANSFORMER

DELUGE SKID FOR BOOSTER COMPRESSOR AREA / BOOSTER COMPRESSOR SUCTION DRUM / BLOW DOWN DRUM

SS05-CAP-C-001A

5500 kVAR, CAPACITOR BANK A

SS05-CAP-C-001B

5500 kVAR, CAPACITOR BANK B

077-DS-021

077-DS-022

DELUGE SKID FOR SS05 TRANSFORMER

DELUGE SKID FOR SS05 TRANSFORMER

PLANT NORTH 0°

TRUE NORTH 0°

135°

N

PREVAILING WIND DIRECTION

UTM COORDINATES E. : 669072.943 N. : 2671135.627

46220

51525

3350

74405

I

D A O R E D W M 4 1 F O C

L

0 0 0 4 5

B

A

0 0 0 9

0 5 8 4 2

0 5 1 1 5

0 0 5 2 6

0 0 7 8 3

0 0 8 2 4

8 0 8 8

G W D S H

0 2 0

G N L R

I

I

T U O Y A L T N E M P U Q E Y T E F A S D N A N O T C E T O R P E R F G N W A R D N O T A U N T N O C

I

I

I

I

C OF 14M WIDE ROAD L

24”

HB 1

4

DUCT BANK

4

12”

D21-PS-013 D21-PS-012

HB 1

4

24”

1

24”X12”

0 0 5

0 0 0 9

086-P-205A/B

086-U-205

086-U-208

16000

8200

12580

1 1 0

S P

1 2 D O T 1 0 0

S P

1 2 D

FGL EL.+100.000

I

T M I L Y R E T T A B

G30-STR-001 PLTF TOS EL.+103.000

G30-PS-001 TO G30-PS-028

G30-PR-005

G30-PR-006

G30-PR-007

SUNSHADE BY VENDOR

17700

2 Z 1 1

Z 0 2 0

1 Z 1 1

Z 0 2 0

2 0 0

V

0 6 0

1 0 0

S P

0 3 G

0 5 5 . 5 5 7 2 :

5 2 1 . 2 1 5 1 :

.

.

E

N

R O T C A R T N O C

R O D N E V

1 0 0

Z

1 6 0

CROSS OVER (BY VENDOR)

C OF 8M WIDE ROAD L

0 0 2 . 3 2 1 + . L E S O T F T L P

A E R A E C N A N E T N A M

I

D25-PR-001 PLTF TOS EL.+117.500

x2

D25-PR-002 PLTF TOS EL.+117.500

E

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

O

F

O

F

O

F

O

F

O

F

O

F

F

A

N

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

F

F

F

F

A

A

N

N

/

/

C B A 1 0 0

E

0 6 0

N

N

A

A

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

F

A

N

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

O

F

O

F

O

F

O

F

O

F

O

F

F

A

N

F

A

N

F

A

N

F

A

N

F

A

N

F

A

N

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

O

F

F

A

N

I

I

I

I

)

(

)

(

T

T

T

T

Y

A

F

F

Y

A

F

F

E

E

P

C

R

D

P

C

R

D

N

O

N

O

N

O

N

O

/

/

C B A 2 0 0

E

0 6 0

O

N

O

N

O

N

O

N

D

R

C

P

D

R

C

P

E

E

F

F

A

Y

F

F

A

Y

T

T

T

T

(

)

(

)

I

I

I

I

D

I

R

E

C

T

I

(

T

Y

O

N

P

)

O

F

F

A

N

AIR COOLER BAY DROP ZONE 12m x 4m

DROP ZONE OF DAVIT ARM 1m x 1m

BATTERY LIMIT

E

1

1

D25-PR-003

077-DS-002

077-DS-021

077-DS-022

4 0 0

R P

5 2 D

HB 1

4

A E R A E C N A N E T N A M

I

1

4

060-V-001-STR-001 PLTF TOS EL.+113.415 PLTF TOS EL.+108.015 PLTF TOS EL.+103.400 060-V-001-STR-002 PLTF TOS EL.+106.115

FP

060-V-001 E. : 2764.200 N. : 1514.000

MAINTENANCE AREA

060-K-001C-V01

060-K-001-STR-001

1 060-K-001C x2

E

1 060-K-001B-V01

060-K-001B E x2

1 060-K-001A-V01

060-K-001A x2

E

PLTF TOS EL.+112.300

PLTF TOS EL.+107.500

1

060-J-001

x2

1

FP

4

2x 060-K-XXX

060-K-001C-Z01

060-K-XXX

060-K-001B-Z01

060-K-XXX

060-K-001A-Z01

2x

0 0 2 . 0 0 1 + . L E P P H

x2

1

MAINTENANCE AREA

4

HB 1

C OF 14M WIDE ROAD L

RESERVED SPACE FOR ROOF MAINTENANCE AREA

1

SS05-TR-C-001A/B

S S E C C A M 4 F O LC

BUILDING SPRINKLER SYSTEM

SS05-TR-D-001

8”

FGL EL.+100.000

HB 2

2

1

24”

4

HB 1

5 0 0

R P

5 2 D

6 0 0

R P

5 2 D

D25-PR-007

CA

3 0

S E

I

C OF 4M ACCESS L

CA

SS05-TR-A-001A/B

SS-05

CA

I

T M I L Y R E T T A B

RESERVED SPACE FOR ROOF

CLEAN AGENT ROOM

S S E C C A M 4 F O C

L

1

MAINTENANCE AREA

R E L L I H C

I

T N U

HVAC ROOM

C OF 4.0M ACCESS L

CA

T N E G A N A E L C

M O O R

1

SS05-CAP-C-001A/B

SS05-TR-C-002A/B

DAY TANK

NER

1 0 2

G E

8 8 0

M W

1

2

C OF 14M WIDE ROAD L

I

D A O R E D W M 4 1 F O C

L

01

02

03

04

05

06

07

08

09

10

11

12

13

CONTINUATION DRAWING FIRE PROTECTION AND SAFETY EQUIPMENT LAYOUT - RLNG-000-HS-DWG-8811

87500

C OF 8M WIDE ROAD L N. : 1606.500

24”X16”

24”

24”

24”X16”

G30-PS-101

G30-PS-108

G30-PS-102

G30-PS-103

4 0 1

S P

0 3 G

G30-PS-107

G30-PS-106

5 0 1

S P

0 3 G

DITCH (TYP)

HB 2

4

24”

UTM COORDINATES E. : 669335.943 N. : 2671135.627

8 2 0

S P

0 3 G

E C N E F A P C C G N I T S I X E

I

9 0 8 8

G W D S H

1 2 0

G N L R

I

I

T U O Y A L T N E M P U Q E Y T E F A S D N A N O T C E T O R P E R F G N W A R D N O T A U N T N O C

I

I

I

I

UTM COORDINATES E. : 669072.943 N. : 2670852.627

CONTINUATION DRAWING FIRE PROTECTION AND SAFETY EQUIPMENT LAYOUT TRAIN 2 - RLNG-211-HS-DWG-0101

DRAWING LIMIT

0 0 5 . 8 3 8 2 . E

UTM COORDINATES E. : 669335.943 N. : 2670852.627

SR No.

EQUIPMENT No.

DESCRIPTION

01

02

03

04

05

06

07

08

060-E-001A

060-E-002A

060-E-001B

060-E-002B

060-E-001C

060-E-002C

058-EH-001

060-J-001

060-K-001A

BOG COMPRESSOR A INTERCOOLER

BOG COMPRESSOR A AFTERCOOLER

BOG COMPRESSOR B INTERCOOLER

BOG COMPRESSOR B AFTERCOOLER

BOG COMPRESSOR C INTERCOOLER

BOG COMPRESSOR C AFTERCOOLER

FUEL GAS HEATER

CRANE FOR BOG SHELTER

BOG COMPRESSOR A

060-K-001A-Z01

BOG COMPRESSOR A LUBE OIL SYSTEM

09

060-K-XXX

LUBE OIL AIRCOOLER

060-K-001A-V01

BOG COMPRESSOR LUBE OIL RUN DOWN TANK

060-K-001B

BOG COMPRESSOR B

10

060-K-001B-Z01

BOG COMPRESSOR B LUBE OIL SYSTEM

060-K-XXX

LUBE OIL AIRCOOLER

060-K-001B-V01

BOG COMPRESSOR LUBE OIL RUN DOWN TANK

060-K-001C

BOG COMPRESSOR C

11

060-K-001C-Z01

BOG COMPRESSOR C LUBE OIL SYSTEM

060-K-XXX

060-K-001C-V01

086-P-205 A/B

086-U-205

086-U-208

060-V-001

060-V-002

061-Z-001

020Z-11Z1

020Z-11Z2

12

13

14

15

16

17

18

19

LUBE OIL AIRCOOLER

BOG COMPRESSOR LUBE OIL RUN DOWN TANK

FIRST FLUSH BASIN PUMP - BOG AREA

FIRST FLUSH BASIN - BOG AREA

OILY WATER STORMCEPTOR - BOG AREA

BOG COMPRESSOR SUCTION DRUM

BOG COMPRESSOR BLOW DRUM

BOG FLARE PACKAGE

BOG FLARE IGNITION PACKAGE

BOG FLARE PROPANE BOTTLE RACK

GENERAL NOTES : A. ALL COORDINATES AND ELEVATIONS ARE IN METERS UNLESS OTHERWISE

NOTED.

B. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE. C. MAXIMUM DISTANCE BETWEEN HYDRANTS SHALL BE 50M FOR PROCESS AND 60M FOR NON-PROCESS AREAS. HYDRANTS SHALL BE LOCATED NOT LESS THAN 1.5 M FROM EDGE OF ROAD SHOULDER AND AT LEAST 10 M FROM CROSSINGS, ROAD TURNS, BUILDINGS AND OTHER STRUCTURES.

D. MONITORS ARE LOCATED AS MINIMUM 15 M FROM THE PROTECTED EQUIPMENT

AND MAXIMUM 50 M FOR PERFORMANCE COVERAGE.

E. HYDRANT SHALL BE READILY ACCESSIBLE FROM ROADS AND BE LOCATED IN

SUCH WAY THAT POSSIBLE DAMAGE BY ROAD TRAFFIC WILL BE MINIMISED AND SHALL BE PROVIDED WITH A GUARD POST AND CONCRETE DRAINAGE AREA.

F. POST INDICATOR VALVE SHALL BE INSTALLED IN VALVE PIT / CHAMBER. G. FIRE ZONES FOR THE LNG PLANT ARE SHOWN IN “OVERALL FIRE ZONE DRAWING

DOC. NO.: RLNG-000-HS-DWG-0001.

H. DELUGE SKIDS SHALL BE LOCATED A MINIMUM OF 30 M FROM THE NEAREST

PROTECTED EQUIPMENT OR HAZARD, OR COMPENSATORY MEASURES SHALL BE PROVIDED. EXACT LOCATION OF HOSE BOX/FIRE POINT/FIRE EXTINGUISHERS SHALL BE ADJUSTED AS PER FIELD CONDITIONS.

I.

J. OUTDOOR EXTINGUISHERS SHALL BE STORED INSIDE POSTED FIBRE GLASS BOXES AND WHEELED EXTINGUISHERS SHALL BE PROTECTED FROM DIRECT WEATHER CONDITIONS BY MEANS OF HEAVY-DUTY WRAPPERS.

K. MAXIMUM TRAVELLING DISTANCES : PORTABLE EXTINGUISHER - 15 M WHEELED EXTINGUISHER - 50 M

L. HOSE BOX SHALL BE PROVIDED AT EVERY ALTERNATE HYDRANTS.

NOTES :

  1. FOR HYDRANT LOCATION ON SOUTH SIDE, REFER TO RLNG-211-HS-DWG-0101.
  2. FIRE FIGHTING SYSTEMS INSIDE BUILDINGS (SS-05 & IES-03) AND EDG WILL BE

DESIGNED BY BUILDING CONTRACTOR.

HOLD: A. LOCATION FOR DELUGE SKIDS WILL BE FINALIZED AFTER FIRE AND EXPLOSION

RISK ASSESSMENT DOC. NO.: RLNG-000-HS-RPT-1013.

SYMBOL

DESIGNATION

QUANTITY

LEGEND

2

4

HB 1

HB 2

HYDRANT (2 X 2 1/2” OUTLETS WITH PRV) WITH 4” PUMPER CONNECTION

FOUR WAY HYDRANT (4 X 2 1/2” OUTLETS WITH PRV) WITH 4” PUMPER CONNECTION

HOSE BOX-TYPE 1 : 2 NOS. X 2 1/2” CONSTANT FLOW COMBINATION FOG/STRAIGHT STREAM NOZZLE 4 NOS. X 2.1/2” X 30 M LAY-FLAT DOUBLE JACKET, RUBBER LINED FIRE HOSE C/W COUPLINGS 2 X COUPLING SPANNERS 2 X DIVIDING BREECHINGS WITH ADAPTOR TO SUIT.

HOSE BOX-TYPE 2 : 2 NOS. X 2 1/2” CONSTANT FLOW COMBINATION FOG/STRAIGHT STREAM NOZZLE 4 NOS. X 2.1/2” X 30 M LAY-FLAT DOUBLE JACKET, RUBBER LINED FIRE HOSE WITH COUPLINGS 6 NOS. X 20 L FOAM CONCENTRATE DRUMS 2 X FOAM BRANCH PIPE 2 X COUPLING SPANNERS 2 X DIVIDING BREECHINGS WITH ADAPTOR TO SUIT.

FIRE POINT : CONTENTS OF HOSE BOX TYPE 1 + ADDITIONAL FOLLOWING ITEMS 4 X 50KG CAPACITY, WHEELED DRY POWDER UNITS 8 X 9KG CAPACITY, DRY POWDER HAND EXTINGUISHERS 1 NO. FIRE BLANKET 3 NOS. FIRE RESISTANT FACE SHIELDS 3 X 92 M FIRE HOSES, 2 1/2” PROVIDED WITH SUITABLE HANGING BRACKETS 2 NOS. X 2 1/2” CONSTANT FLOW COMBINATION FOG/STRAIGHT STREAM NOZZLE

FP

1

POST INDICATOR VALVE

077-DS-XXX

DELUGE VALVE SKID

PROTECTED BY WATER SPRAY SYSTEM

PROTECTED BY SPRINKLER SYSTEM

CA

CLEAN AGENT SYSTEM

WM

WATER MIST SYSTEM

12 KG, POTASSIUM BICARBONATE B:C DRY CHEMICAL PORTABLE FIRE EXTINGUISHER

50 KG, POTASSIUM BICARBONATE B:C DRY CHEMICAL WHEELED FIRE EXTINGUISHER

E

12 KG, POTASSIUM BICARBONATE B:C DRY CHEMICAL PORTABLE FIRE EXTINGUISHER ELEVATED

5 KG, CO2 EXTINGUISHER

FOAM WHEELED FIRE EXTINGUISHER (50 L)

SAFETY SHOWER AND EYE WASH

FIRE WATER PIPE - UNDERGROUND

FIRE WATER PIPE - ABOVEGROUND

1

2

9

5

2

1

2

1

21

3

AS SHOWN

AS SHOWN

AS SHOWN

AS SHOWN

20

3

8

3

1

2

1

THIS DRAWING NOT TO BE USED AS PLOT PLAN

0

10

20

30

40

50M

REFERENCE DOCUMENTS

DRAWING NO.

TITLE

RLNG-D21-PI-DWG-8000

UNIT PLOT PLAN BOG COMPRESSOR & FLARE

RLNG-000-HS-PP-0101

ACTIVE FIRE PROTECTION PHILOSOPHY

RLNG-000-HS-NC-0101

FIRE WATER DEMAND CALCULATION NOTE

RLNG-077-HS-PID-8801

RLNG-077-HS-PID-8861

RLNG-077-HS-PID-8875

RLNG-077-HS-PID-8858

PID - FIREWATER - BOG COMPRESSOR AND BOG FLARE AREA

PID - FIREWATER - DELUGE DISTRIBUTION - SS05 - 01/02

PID - FIREWATER - DELUGE DISTRIBUTION - SS05 - 02/02

PID - FIREWATER - DELUGE DISTRIBUTION SYSTM - BOG COMPRESSORS

RLNG-000-HS-DWG-0105

TYPICAL INSTALLATION FIRE PROTECTION EQUIPMENT

1

PLANT NORTH 0°

TRUE NORTH 0°

N

135° PREVAILING WIND DIRECTION

KEY PLAN

THIS DRAWING

1:20 SLOPE

1:20 SLOPE

/17V-50B /01701-STRC_UG-CWS-003 /01701-STRC_UG-PAV =67127078/73820 =67127078/74494 =67127078/74842 =67127078/89964 =67127078/89868 =67127078/90045 /PLT_17V51B-2 /PLT_17V51A-2 /Copy-of-PLT_17V51B-1 /PLT_17V51B-1 =67127078/90290 =67127078/82069 =67127078/88890 =67127078/88638 =67127078/88386 =67127078/89631 =67127078/89379 =67127078/91113 =67127078/91090 =67127078/89127 =67127078/90890 /DIESEL-17Z-51T1 =67127078/90989 /AIR_COOLER_2 /AIR_COOLER_1 /17Z-93 /17Z-66 /17Z-65 /17Z-64 /17Z-63 /17Z-61 /17Z-50/Z2 /17Z-50/Z1 /17Z-50A /17Z-50B /17Z-51 /17V-51B /17V-51A /17T-7 /17T-6 /17T-8 /17T-11 /17P-51B /17P-51A /17P-50A /17P-50B /17P-4B /17P-4A /17P-41B /17P-41A /17V-50A /17V-50B /17Z-62 =67127078/80376 /ROAD /17MUL-TWR-002 /01701-STRC_B/TB /01701-STRC_UG-CWS-002 /01701-STRC_UG-CWS-005 /01701-STRC_UG-FT-CWS-005 /01700-STRC_UG_EMBK_RD /01700-STRC_UG_RD /01700-STRC_UG_FGL /01700-STRC_UG_EMBK_RD /01700-STRC_UG_RD /01700-STRC_UG_FGL =67127078/74842 =67127078/74494 =67127078/73820 =67127078/80376 /ROAD /MARINE_TOWER /01701-STRC_B/TB /01701-STRC_B/SB

/PAVING /17E-41A /17E-41B /17E-41C /17E-41D /17E-41E /17E-41F /17E-41G /17E-41H /17E-41I /17E-41J /17E-41K /17E-41L /17E-42A /17E-42C /17E-42B /17E-42D /17F-44 /17F-56 /17F-57 /17V-56 /17V-57 /17V-60 /MERCURY_ADSORBER_PLATFORM /PROPANE_MOISTURE_GUARD_BEDS_PLATFORM =67127083/23038 =67127083/23131 /ETHYLENE_bullets_PLATFORM-1 /ETHYLENE_bullets_PLATFORM-2

1

0A

0

23-Apr-2025

10-Feb-2025

13-Dec-2024

REV

DATE

SCALE:

DRAWN:

IFC - Issued For Construction

ICR - Issued for Client Review

RS

RS

DS

DS

JM/MV

JM/MV

J

ICR - ISSUED FOR CLIENT REVIEW

DSD/KN DS

JM/MV

DESCRIPTION

CHKD:

DRAWN

CHKD

APPRD

APPRD:

1:500

RAJASEKHAR

DILIP SHAH

J.MENDEZ REPISO

ADNOC Gas

CONTRACTOR

PROJECT TITLE

DRAWING TITLE

RUWAIS LNG PROJECT

Fire Protection & Safety Layout BOG Compressor & Flare

A

B

C

D

E

F

G

H

I

K

L

G W D . 1 _ 7 0 8 8

G W D S H

0 6 0

G N L R

: .

O N D A C

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

ADNOC GAS PROJ. No. 22-146

ADNOC GAS DWG. No.

RLNG-060-HS-DWG-8807 17

16

SHEET 01/01

REV. 1

SHEET SIZE : A0

SCALE 1 : 500

UNIT:

060

PLANT:

RUWAIS

DOC. CLASS:

CONTR. PROJ. No.

215122C

CONT. DWG. No.:

ADNOC GAS AGREEMENT No.

4700022871

OC DWG. No.:

DOC. CAT:

2 215122C-060-DW-1933-8807

A

B

C

D

E

F

G

H

I

J

K

L

R O F Y L P P A L L A H S 6 4 1

2 2 N O C

:

O N T N E M E E R G A

/

T C A R T N O C F O S M R E T E H T

.

I

Y T R A P D R H T Y N A O T T N E M U C O D S H T F O E R U S O L C S D Y N A

I

I

Project: Q-32859 - NMDC - Ruwais Folder: RFQ Files


Loading authentication...

Graph View

Backlinks

  • 00 Index

Created with Infinity Constructor © 2025

  • Elynox | Go Further