CONTINUATION DRAWING FIRE PROTECTION AND SAFETY LAYOUT - TRAIN 1 RLNG-111-HS-DWG-0101
OF 12M ROAD N. 982.000
349500
CONTINUATION DRAWING FIRE PROTECTION AND SAFETY LAYOUT - TRAIN 2 RLNG-211-HS-DWG-0101
24”
0 5 7 . 5 8 4 2
.
E
B11-PR-005
B11-PR-006
B11-PR-007
B11-PR-008
B11-PR-009
B11-PR-010
8”
B11-PR-011
2
PE 2533.300 PN 946.300
OF 6M ROAD N. 936.600
IES-04
B13-STR-001
086-P-103A/B
086-U-108
086-U-103
010-AS-04
4
010-Z-001
MAINTENANCE AREA
HAVC OUTDOOR SPACE
MAINTENANCE AREA
4
010-F-001B
010-F-001A
2 1 0
R P
1 1 B
BARRIER WALL
PIG RECEIVING TROLLEY
I
K C A R E P P E R U T U F
2
D A O R M 6 F O
0 0 5 . 3 8 5 2 .
E
4
10”
JIB CRANE
D A O R M 6 F O
0 0 7 . 8 8 6 2 .
E
8”
FP
10”
8”
24”
HB 1
2
4
OF 12M ROAD N. 855.000
24”
HB 1
4
010-V-001
0 0 5 . 3 3 7 2 E
E C N A N E T N A M
I
A E R A
4
D A O R M 6 F O
0 0 5 . 9 1 7 2 .
E
EQUIPMENT LIST ITEM NO. 010-V-001 010-F-001A/B 010-Z-001 086-U-108 086-U-103 086-P-103A/B
DESCRIPTION PIG RECEIVER INLET GAS FILTER LNG PLANT INLET GAS METERING STATION OILY WATER STORMCEPTOR - INLET FACILITY AREA FIRST FLUSH BASIN - INLET FACILITY AREA FIRST FLUSH BASIN PUMP - METERING AREA
BUILDING LIST ITEM NO. IES-04 010-AS-04
DESCRIPTION INSTRUMENT EQUIPMENT SHELTER ANALYZER SHELTER
A. B. C.
D.
E.
F.
G.
H.
I.
J.
K.
GENERAL NOTES
ALL COORDINATES ARE IN METERS UNLESS NOTED OTHERWISE. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE. MAXIMUM DISTANCE BETWEEN HYDRANTS SHALL BE 50M AND HYDRANTS SHALL BE LOCATED NOT LESS THAN 1.5M FROM ROAD EDGE AND AT LEAST 10M FROM CROSSINGS, ROAD TURNS, BUILDINGS AND OTHER STRUCTURES. HYDRANT SHALL BE READILY ACCESSIBLE FROM ROADS AND BE LOCATED IN SUCH WAY THAT POSSIBLE DAMAGE BY ROAD TRAFFIC WILL BE MINIMISED AND SHALL BE PROVIDED WITH A GUARD POST AND CONCRETE DRAINAGE AREA. MONITORS ARE LOCATED AS MINIMUM 15M FROM THE PROTECTED EQUIPMENT AND MAXIMUM 50M FOR PERFORMANCE COVERAGE. POST INDICATOR VALVE SHALL BE INSTALLED IN VALVE PIT / CHAMBER. IT SHALL BE LOCATED SUCH SINGLE IMPAIRMENT WILL NOT INVOLVE MORE THAN SIX FIRE FIGHTING EQUIPMENT. FIRE ZONES FOR THE MAIN LNG PLANT ARE SHOWN IN, FIRE ZONE LAYOUT DRAWING NO. RLNG-000-HS-DWG-0001. EXACT LOCATION OF FIRE EXTINGUISHER SHALL BE ADJUSTED AS PER FIELD. MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER SHALL BE NOT MORE THAN 15 M WITHIN AREA OR AROUND PROTECTED EQUIPMENT. OUTDOOR FIRE EXTINGUISHERS SHALL BE PLACED INSIDE POSTED FIBERGLASS BOXES. WHEELED EXTINGUISHERS SHALL BE PROTECTED FROM DIRECT WEATHER CONDITIONS BY MEANS OF CANOPY OR HEAVY DUTY WRAPPERS. FIRE FIGHTING SYSTEMS INSIDE BUILDINGS WILL BE DESIGNED BY BUILDING SUB-CONTRACTOR.
REFERENCE DOCUMENTS
RLNG-000-HS-RP-0101
ACTIVE FIRE PROTECTION PHILOSOPHY
RLNG-000-HS-NC-0101
FIRE WATER DEMAND CALCULATION NOTE
RLNG-010-PI-DWG-5001
UNIT PLOT PLAN INLET FACILITIES-1
A
B
C
D
KEY PLAN
PLANT NORTH 0°
TRUE NORTH 0°
N
PREVAILING WIND DIRECTION
/42LA-01A_X /42LA-01A /42LA-01A_SVU /42LA-01A /42LA-01A_X /42LA-01A_SVU
/42LA-01B_X /42LA-01B /42LA-01B_SVU /42LA-01B /42LA-01B_X /42LA-01B_SVU
/42LA-02_X /42LA-02 /42LA-02 /42LA-02_X
/42LA-01C_X /42LA-01C_SVU /42LA-01C /42LA-01C_SVU /42LA-01C_X /42LA-01C
/42L-3403 /42L-3403 /42L-3403
/04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B
/04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B
/04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B
/04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B
/04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B
/04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B /04204-CAPSTAN-B1M5-B
E
PE 2846.500 PN 982.000
24”
HB 1
4
24”
I
T M I L G N W A R D
I
24”
TIE-IN WITH CPY N. 905.000 E. 2780.000 BOP EL.+102.000
24”
D A O R M 2 1 F O
0 0 5 . 8 3 8 2 .
E
8”
4
8”
E S U O H E T A G O T
/20K-9A-E1 /20K-9C-E2 /20K-9A-E2 /20K-9B-E1 /20K-9B-E2 /20K-9C-E1 /20K-9C-E2 /20K-9A-E1 /20K-9A-E2 /20K-9B-E1 /20K-9B-E2 /20K-9C-E1
/20K-9A
/20-EB-01_TR-BAY_VOL /20-EB-01_TR-BAY_VOL
/20IB-01 /20IB-01
/01701-STRC_UG-CWS-003 /17V-50B /01701-STRC_B/SB /01701-STRC_B/TB /MARINE_TOWER /ROAD =67127078/80376 =67127078/73820 =67127078/74494 =67127078/74842 /01700-STRC_UG_FGL /01700-STRC_UG_RD /01700-STRC_UG_EMBK_RD /01700-STRC_UG_FGL /01700-STRC_UG_RD /01700-STRC_UG_EMBK_RD /01701-STRC_UG-FT-CWS-005 /01701-STRC_UG-CWS-005 /01701-STRC_UG-CWS-002 /01701-STRC_B/TB /17MUL-TWR-002 /ROAD =67127078/80376 /17Z-62 /17V-50B /17V-50A /17P-41A /17P-41B /17P-4A /17P-4B /17P-50B /17P-50A /17P-51A /17P-51B /17T-11 /17T-8 /17T-6 /17T-7 /17V-51A /17V-51B /17Z-51 /17Z-50B /17Z-50A /17Z-50/Z1 /17Z-50/Z2 /17Z-61 /17Z-63 /17Z-64 /17Z-65 /17Z-66 /17Z-93 /AIR_COOLER_1 /AIR_COOLER_2 =67127078/90989 /DIESEL-17Z-51T1 =67127078/90890 =67127078/89127 =67127078/91090 =67127078/91113 =67127078/89379 =67127078/89631 =67127078/88386 =67127078/88638 =67127078/88890 =67127078/82069 =67127078/90290 /PLT_17V51B-1 /Copy-of-PLT_17V51B-1 /PLT_17V51A-2 /PLT_17V51B-2 =67127078/90045 =67127078/89868 =67127078/89964 =67127078/74842 =67127078/74494 =67127078/73820 /01701-STRC_UG-PAV
/ETHYLENE_bullets_PLATFORM-2 /PAVING /ETHYLENE_bullets_PLATFORM-1 =67127083/23131 =67127083/23038 /PROPANE_MOISTURE_GUARD_BEDS_PLATFORM /MERCURY_ADSORBER_PLATFORM /17V-60 /17V-57 /17V-56 /17F-57 /17F-56 /17F-44 /17E-42D /17E-42B /17E-42C /17E-42A /17E-41L /17E-41K /17E-41J /17E-41I /17E-41H /17E-41G /17E-41F /17E-41E /17E-41D /17E-41C /17E-41B /17E-41A
24”
4
24”
HB 1
4
24”
THIS DRAWING
PE 2497.000 PN 847.000
CONTINUATION DRAWING FIRE PROTECTION AND SAFETY LAYOUT - REFRIGERANT STORAGE RLNG-077-HS-DWG-5102
DRAWING LIMIT
FOR FUTURE EXPANSION
PE 2846.500 PN 847.000
SYMBOL AND LEGEND
SYMBOL
DESCRIPTION
QTY.
4
2
4
FP
HB 1
FOUR WAY HYDRANT (4 x 2 1/2” OUTLETS WITH PRV) WITH 4” PUMPER CONNECTION
TWO WAY HYDRANT (2 x 2 1/2” OUTLETS WITH PRV) WITH 4” PUMPER CONNECTION FOUR WAY HYDRANT (4 x 2 1/2” OUTLETS WITH PRV) WITH MONITOR AND 4” PUMPER CONNECTION
POTASSIUM BICARBONATE (PURPLE K) DRY CHEMICAL PORTABLE FIRE EXTINGUISHER (12 KG)
POST INDICATOR VALVE
FIRE POINT
1 x HOSE BOX, 4 x 50 KG WHEELED DRY CHEMICAL FIRE EXTINGUISHER, 8 x 9 KG DRY CHEMICAL FIRE EXTINGUISHER, 1 x FIRE BLANKET, 3 x FIRE RESISTANT FACE SHIELDS, 3 x 30 M FIRE HOSES 2 1/2” PROVIDED WITH SUITABLE HANGING BRACKETS 2 x FIRE WATER / FOAM NOZZLES, SPRAY/STRAIGHT STREAM
HOSE BOX - TYPE 1
2 x 2 1/2” (65 mm) CONSTANT FLOW COMBINATION FOG / STRAIGHT STREAM NOZZLE 4 x 2 1/2” (65 mm) x 30 m LAY-FLAT DOUBLE JACKET, RUBBER LINES FIRE HOSE C/W COUPLINGS 2 x COUPLING SPANNERS
06
04
04
09
08
01
05
PROTECTED BY OSCILLATING MONITOR
FIRE WATER DISTRIBUTION (UG)
FIRE WATER DISTRIBUTION (AG)
AS SHOWN
AS SHOWN
AS SHOWN
1
2
3
4
5
6
7
8
9
10
11
12
13
-10
0
10
20
30
40
50
60
SCALE 1:600
METERS
0
13-Dec-2024
ICR - Issued for Client Review
A.PATNI K.NITTA T.SAKAMOTO
REV
DATE
SCALE:
DRAWN:
DESCRIPTION
CHKD:
DRAWN
CHKD
APPRD
APPRD:
1:600
A. PATNI
K. NITTA
T. SAKAMOTO
ADNOC Gas
CONTRACTOR
PROJECT TITLE
DRAWING TITLE
RUWAIS LNG PROJECT
FIRE PROTECTION AND SAFETY LAYOUT INLET FACILITIES - 1
UNIT:
077
PLANT:
RUWAIS
DOC. CLASS:
CONTR. PROJ. No.
215122C
CONT. DWG. No.:
ADNOC GAS AGREEMENT No.
4700022871
OC DWG. No.:
DOC. CAT:
2 215122C-077-DW-1933-5101 DL-077-12412-5101
ADNOC GAS PROJ. No. 22-146
14
ADNOC GAS DWG. No.
RLNG-077-HS-DWG-5101
15
SHEET
REV.
01/01
0
SHEET SIZE : A1 1 / 1
PLANT NORTH 0°
TRUE NORTH 0°
N
PREVAILING WIND DIRECTION
PE 2497.000 PN 982.000
I
G N W A R D N O T A U N T N O C
I
I
E G A R O T S T N A R E G R F E R
I
T U O Y A L Y T E F A S D N A N O T C E T O R P E R F
I
I
0 0 0 5 3 1
2 0 1 5
G W D S H
7 7 0
G N L R
0 0 0 . 7 9 4 2
.
E
HB 1 2
D A O R M 2 1 F O
18”
24”
24”
A
B
C
D
E
F
G
H
I
J
R O F Y L P P A L L A H S 6 4 1
2 2 N O C
:
O N T N E M E E R G A
/
T C A R T N O C F O S M R E T E H T
.
I
Y T R A P D R H T Y N A O T T N E M U C O D S H T F O E R U S O L C S D Y N A
I
I
J-DMS 16-Dec-2024 UNCONTROLLED WHEN PRINTED
F
G
H
I
J
G W D . 1 0 1 5
G W D S H
7 7 0
G N L R
: .
O N D A C
Project: Q-32859 - NMDC - Ruwais Folder: RFQ Files