7 8 9

1 5 0 0

0 8 8 0

M D

Z S

9 3 4 4

U G

U G

U G

U G

U G

U G

U G

U G

U G

U G

U G

U G

U G

U G

U G

U N N 0 B 1 V

2 7 0

0 8 8

W P

” 4

U G

U G

U G

U G

U G

U G

U G

U G

U G

U G

U G

U G

U G

U G

4”x3”

3”x2”

I

T N E S N O C N E T T R W R O R P T U O H T W

I

I

,

E S O P R U P Y N A R O F S R E H T O Y B D E S U E B T O N N A C D N A Y T R E P O R P S T N O M N C E T S

I

’

I

T N E M U C O D S H T

I

060-XX-001

SS

SAFETY SHOWER AND EYE WASH LABORATORY

” 2 / 1

1 x ” 2

CL

N N 0 A 1 K

9 8 0

0 8 8

W P

” 2

3 0 8 8

O L

L L C C

G U

UG

UG

.

I

N M

RO XXX

3 0 8 8

N N 0 A 1 K

8 8 0

0 8 8

W P

” 2

U G

U G

U G

U G

2”-PW-880-072-V1B0NNU-

UG

UG

8806

UG

UG

UG

UG

2”-PW-880-073-V1B0NNU- UG

UG

UG 8806

6 0 8 8

G U

G U

G U

G U

G U

G U

G U

G U

G U

G U

G U

G U

G U

UG

G U

CL

UG

UG

6 0 8 8

U N N 0 B 1 V

3 7 0

0 8 8

W P

” 4

4”x3”

3”x2”

UG

UG

UG

UG

UG

CL

G U

G U

G U

G U

G U

G U

UG

UG

UG

UG

UG

UG

UG

UG

SS AND EW INSTRUMENT TAG NUMBER

TAG NO.

FSH TAG

FAH TAG

FXL TAG

FXA TAG

FO TAG

060-XX-001

060-FSH-551

060-FAH-551

060-FXL-551

060-FXA-551

060-FO-541

050-XX-001

050-FSH-552

050-FAH-552

050-FXL-552

050-FXA-552

060-FO-542

040-XX-101

040-FSH-553

040-FAH-553

040-FXL-553

040-FXA-553

060-FO-543

930-XX-001

930-FSH-554

930-FAH-554

930-FXL-554

930-FXA-554

060-FO-544

930-XX-002

930-FSH-555

930-FAH-555

930-FXL-555

930-FXA-555

060-FO-545

REFER TO DETAIL “B” FOR EYE WASH HOOK UP

REFER TO DETAIL “A” FOR SAFETY SHOWER HOOK UP

DETAIL “B”

FXA XXXXX

DETAIL “A”

NOTE 1

FXA XXXXX

FAH

XXXXX

FGS

FSH

XXXXX

FXL

XXXXX

FAH

XXX XX

FGS

NOTE 1

FXL

XXXXX

FSH

XXXXX

GENERAL NOTES:

A) ALL INSTRUMENTS TAG NUMBERS ARE PREFIXED BY SECTOR CODE “XXX”. B) SCOPE BREAK BETWEEN VENDOR AND CONTRACTOR IS INDICATED AS VENDOR CONTRACTOR. C) RISER ON TRANSITION FROM UNDERGROUND TO ABOVEGROUND PIPING SHALL BE EQUIPPED WITH PROTECTION FROM PHYSICAL DAMAGE WHERE NECESSARY. D) PIPE CLASSES : K1A0NN - POTABLE WATER PIPE ABOVE GROUND V1B0NNU - POTABLE WATER PIPE UNDERGROUND

BY EPC CONTRACTOR

BY VENDOR

BY EPC CONTRACTOR

BY VENDOR

NOTES:

TO U / G SEWER (NOTE 2)

TO U / G SEWER (NOTE 2)

  1. ACTIVATION OF THE OUTDOOR SAFETY SHOWER WILL ACTUATE A VISUAL AND AUDIBLE ALARM AT THE SHOWER.
  2. SAFETY SHOWER / EYE WASH DRAIN SHALL BE ROUTED TO THE NEAREST U/G SEWER.
  3. LEGEND

SS

SAFETY SHOWER EYE WASH

EW EYE WASH

1 5 0 0

0 8 8 0

M D

Z S

9 3 4 4

1 9 9

G U

G U

G U

G U

G U

G U

G U

G U

G U

UG

CL

G U

UG

G U

UG

UG

CL

3”-PW-880-075-V1B0NNU- UG

UG

UG 8806

3”-PW-880-074-V1B0NNU- UG

UG

UG

3”-PW-880-076-K1A0NN-

UG

UG

G U

UG

UG

UG

UG

UG

UG

8806

8803

G U

3”x2”

2”-PW-880-094-V1B0NNU- UG UG UG 8806

G U

G U

UG

UG

UG

UG

UG

UG

UG

UG

3”x2”

2”-PW-880-095-V1B0NNU-

UG

UG

UG

UG

AG

CLCL

3”-PW-880-077-K1A0NN-

8803

AG

UG

CLCL

L L C C

UG

AG

LO

U G

U G

U G

U G

G U

G U

G U

G U

N N 0 A 1 K

9 7 0

0 8 8

W P

” 2

3 0 8 8

RO XXX

N N 0 A 1 K

8 7 0

0 8 8

W P

” 2

3 0 8 8

CL 2”x1-1/2”

.

I

N M

U G

U G

U G

U G

L L C C

UG

AG

LO

8806

G U

G U

G U

G U

N N 0 A 1 K

1 8 0

0 8 8

W P

” 2

3 0 8 8

RO XXX

N N 0 A 1 K

0 8 0

0 8 8

W P

” 2

3 0 8 8

CL 2”x1-1/2”

.

I

N M

G U

G U

G U

U G

U G

U G

REFERENCES:

4439-VZ-DM-0000-0001 ÷ 0012 PIPING & INSTRUMENTATION DIAGRAM GENERAL NOTES, SYMBOL AND LEGEND PIPING SYMBOLS 4439-SZ-SG-000000001 HSE GENERAL SPECIFICATION 4439-SX-DG-100000001 FIRE PROTECTION GENERAL LAYOUT

2”-PW-880-106-K1A0NN-

8803

RO XXX

MIN.

UG

UG AG CLCL

LO

L C

2”x1-1/2”

2”-PW-880-107-K1A0NN-

8803

SS

930-XX-002

SAFETY SHOWER AND EYE WASH LAB TRUCK LOADING ARMS

HOLDS:

  1. SAFETY SHOWER EYEWASH AND EYEWASH QUANTITY WILL BE UPDATED WHEN RESPECTIVE FF & SAFETY EQUIPMENT, ESCAPE ROUTES AND SAFETY SIGNS LAYOUT IS FINALISED.
  2. TAGS FOR SAFETY SHOWERS AND EYE WASH WILL YO BE INDICDATED AFTER ISSUANCE OF ESCAPE ROUTE LAYOUTS.

2”-PW-880-090-V1B0NNU- UG

UG

UG 8806

2”-PW-880-091-V1B0NNU-

UG

UG

UG

8806

SS

040-XX-001

SAFETY SHOWER AND EYE WASH HAB DRUM FILLING ROOM

SS

930-XX-001

SAFETY SHOWER AND EYE WASH LAB TRUCK LOADING ARMS

2”-PW-880-092-K1A0NN-

8803

RO XXX

MIN.

UG

LO

UG AG CLCL

L C

2”x1-1/2”

2”-PW-880-093-K1A0NN-

8803

EW 050-XX-001

EYE WASH BATTERY ROOM SUBSTATION US-005

0

03/Jan/2025

IFA-Issued for Approval

K.Jeetu

M.Ligouras/G.Acerbi/ E.Magadeev/ H.Aljarrah

M.Ligouras

 Realisation en EPC d'installations de production de

LINEAR-ALKYL-BENZENE <> a SKIKDA ALGERIE CT-EPC/017/SH/EPM/RPC-X/2023

PIPING & INSTRUMENTATION DIAGRAM SAFETY SHOWER SYSTEMS 2

4439-SZ-DM-0880-0052

A1

Echelle :

1/1

1 of 1

Rev :

0