INSTRUMENT AND CONTROL EQUIPMENT NUMBERING FOR LABK COMPLEX

UUU-AAAAA-XXXDD

UNIT/SECTION NUMBER (3 DIGITS)

IDENTIFICATION LETTER (MAX. 5 UPPERCASE LETTERS TO IDENTIFY PROCESS VARIABLE & FUNCTION AS PER ISA 5.1 TABLE 4.1)

SEQUENCE NUMBER

SUFFIX (NO 2 DIGIT WHERE NECESSARY)

GENERAL INSTRUMENTS

FIELD-MOUNTED INSTRUMENT

BEHIND CONTROL BOARD INSTRUMENT (RACK OR BEHIND PANEL)

FRONT CONTROL BOARD PRIMARY LOCATION INSTRUMENT (CONSOLE OR PANEL)

AUXILIARY LOCATION INSTRUMENT (LOCAL PANEL)

SHARED INSTRUMENTS, NOT NORMALLY ACCESSIBLE TO OPERATOR

SHARED INSTRUMENTS, BEHIND-THE-PANEL DEVICES OR FUNCTIONS NORMALLY INACCESSIBLE

SHARED INSTRUMENTS, NORMALLY ACCESSIBLE TO OPERATOR

SHARED INSTRUMENTS, AUXILIARY OPERATOR’S INTERFACE DEVICES

DUAL FUNCTION OR INSTRUMENTS SHARING COMMON HOUSING

BEHIND AUXILIARY LOCATION (BEHIND LOCAL PANEL)

H

L

CRITICAL SOFTWARE ALARM

CRIT

CRITICAL SHUTDOWN ALARM

COMPUTER, NOT NORMALLY ACCESSIBLE TO OPERATOR

COMPUTER, BEHIND-THE-PANEL DEVICES OR FUNCTIONS NORMALLY INACCESSIBLE

COMPUTER, NORMALLY ACCESSIBLE TO OPERATOR

COMPUTER, AUXILIARY LOCATION

ESD FUNCTION. ALARM SIGNAL SHALL BE REPEATED IN DCS.

IS

GENERIC INTERLOCK OR OTHER FUNCTION

TANK GAUGING SYSTEM

GS

(OPERATOR ACCESIBLE)

FIRE AND GAS DETECTION SYSTEM

PROGRAMMABLE LOGIC CONTROLLER FUNCTION

FGS

PLC

MMS

NUMBERING CRITERIA AND SYMBOLOGY FOR INTERLOCK/LOGIC

I XXX

YYY

XXX SEQUENTIAL NUMBER

ID XXX

DCS LOGIC FUNCTION (NORMALLY NOT ACCESSIBLE)

MMS: MACHINE MONITORING SYSTEM

PLC: PROGRAMMABLE LOGIC COMPUTER

FGS: FIRE AND GAS

YYY:

AS: ANTISURGE CONTROLLER

CC: CAPACITY CONTROL SC: SPEED CONTROLLER TGS: TANK GAUGING SYSTEM

COMPLETE LOGIC NUMBERS WILL BE PREFIXED BY UNIT NUMBER: e.g. UUU-ID-XXX

(IN CASE OF LOGIC AFFECTING MORE THAN ONE UNIT, THE MOST IMPORTANT SHALL BE USED

AS A REFERENCE)

NOTE:

LOGICS ON P&ID SHALL BE REPRESENTED IN THE MOST SIMPLE WAY, MINIMIZING THE QUANTITY OF INTERCONNECTING LINES.

OTHER DEVICES

R

1

FO

PILOT LIGHT FIELD-MOUNTED

PILOT LIGHT ON CONTROL BOARD

PILOT LIGHT ON LOCAL PANEL

RESET FOR LATCH-TYPE ACTUATOR

DIAPHRAGM SEAL

FLOW RESTRICTION ORIFICE

FLOW METER GENERAL

VORTEX FLOW METER

CORIOLIS TYPE FLOW METER

ULTRASONIC FLOW METER

ORIFICE PLATE

PITOT TUBE

AVERAGING PITOT TUBE

VENTURI METER

FLOW NOZZLE

FG

ROTAMETER

TURBINE FLOW METER

POSITIVE DISPLACEMENT FLOW METER

STRAIGHTENER FOR TURBINE FLOW METER

WEIR FLOW METER

PURGING WITH NITROGEN OR ANOTHER GAS

RADIOACTIVE SOURCE

WASHING CONNECTION

WEDGE FLOW METER

SIGHT GLASS

THERMAL MASS

P

W

SG

T

M

MAGNETIC FLOW METER

PREFABRICATED METER RUN *1 *1 - STATING THAT STRAINER TO BE ADDED AT THE INLET OF THE PREFABRICATED METER RUN

INSTRUMENTATION LINES

INSTRUMENT SUPPLY OR CONNECTION TO PROCESS PNEUMATIC SIGNAL

ELECTRICAL SIGNAL

SOFTWARE OR DATA LINK

CAPILLARY TUBE (FILLED SYSTEM)

ELECTROMAGNETIC, SONIC, LIGHT BEAM OR RADIOACTIVE SIGNAL (NOT GUIDED)

HYDRAULIC SIGNAL

MECHANICAL LINKAGE

1

FUNCTION IDENTIFICATION

REFER TO LIST BELOW FOR IDENTIFICATION

<

HIGH SELECTOR

LOW SELECTOR

HIGH LIMITER

LOW LIMITER

BIAS

K

Σ

∆

X

PROPORTIONAL

Σ n

AVERAGING

SUMMING

DIFFERENCE

MULTIPLYING

SQUARE ROOT

÷

S

dtd

-K

DIVIDING

INTEGRAL

DERIVATIVE

REVERSE PROPORTIONAL

POWER FUNCTION

UNSPECIFIED FUNCTION

INPUT/OUTPUT OF THE FOLLOWING

  • DISIGNATION

SIGNAL

A

B

D

E

H

I

O

P

R

ANALOG

BINARY

DIGITAL

VOLTAGE

HYDRAULIC

CURRENT

ELECTROMAGNETIC

PNEUMATIC

RESISTANCE

NOTE 1

1

1

VALVE ACTUATORS

1

D

ROTARY MOTOR

DIGITAL

ELECTRO HYDRAULIC

SPRING DIAPHRAGM WITH POSITIONER

ACTUATOR

ACTUATOR WITH HANDWHEEL

HAND

ON/OFF CYLINDER OR PISTON

P

AIR MOTOR

M

E

H

S

WITH HANDWHEEL

GENERIC DIAPHRAGM

SOLENOID

CYLINDER/PISTON WITH HANDWHEEL

INSTRUMENTS IDENTIFICATION LETTERS

(Refer to ISA 5.1 Table 4.1for complete details)

FIRST LETTER

SUBSEQUENT LETTERS

MEASURED VARIABLE

MODIFIER 1

READOUT OR

OUTPUT

MODIFIER 2

GENERAL NOTES:

USER’S CHOICE

USER’S CHOICE

CONTROL

CLOSE

DEVIATION

NOTE 22

1

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

ANALYSIS

BURNER, COMBUSTION USER’S CHOICE

USER’S CHOICE DENSITY

VOLTAGE

FLOW, FLOW RATE

USER’S CHOICE

HAND (MANUAL)

CURRENT

(ELECTRICAL) POWER

TIME, SCHEDULE

LEVEL

USER’S CHOICE

(MOTORIZED VALVE) USER’S CHOICE

USER’S CHOICE

PRESSURE, VACUUM

QUANTITY

RADIATION

SPEED, FREQUENCY

TEMPERATURE

MULTIVARIABLE

VIBRATION, MECH ANALYSIS

WEIGHT, FORCE

UNCLASSIFIED

EVENT, STATE, PRESENCE

POSITION

COMPENSATED

DIFFERENCE, DIFFERENTIAL

RATIO (FRACTION)

TIME RATE OF CHANGE

INTEGRATE, TOTALIZE

SAFETY

X-axis

Y-axis

Z-axis, Safety Instrument System

ALARM

USER’S CHOICE

SENSOR, PRIMARY ELEMENT

GLASS, GAUGE VIEWING DEVICE

INDICATE

SCAN

LIGHT

ORIFICE, RESTRICTION

POINT (TEST CONN)

INTEGRATE, TOTALIZE

RECORD

MULTIFUNCTION

WELL, PROBE ACCESSORY DEVICE, UNCLASSIFIED

USER’S CHOICE

USER’S CHOICE

CONTROL STATION

SWITCH

TRANSMITTER

MULTIFUNCTION

VALVE, DAMPER, LOUVER

PRESSURE SAFETY VALVE NUMBERING FOR LABK COMPLEX

UUU-PSV-XXXD

UNIT/SECTION NUMBER (3 DIGITS)

CODE OF PRESSURE SAFETY VALVE (INCLUDING THERMAL RELIEF VALVE)

SEQUENCE NUMBER

REFERENCE LETTER (AS A REFERENCE FOR IDENTICAL PSV’S I.E. A,B,C INVOLVED FOR THE SAME SERVICE INCLUDING SPARES).

PRESSURE RELIEVING DEVICES

HIGH

LOW

MIDDLE, INTERMEDIATE

USER’S CHOICE

OPEN

RUN (START)

STOP

NOTES:

GENERIC CONTROL VALVE SYMBOL (DIAPHRAGM WITH POSITIONER) WILL BE USED. ACTUAL ACTUATOR TYPE SHALL BE DEFINED ON PIDs.

1

WHEN MODIFIER 2 IS APPLICABLE A NOTE WILL BE SPECIFIED STATING THE FUNCTIONALITY.

HOLDS:

UNCLASSIFIED

UNCLASSIFIED

AUXILIARY DEVICE (RELAY, COM PUTE, CONVERT,…)

DRIVER, ACTUATOR, UNCLASSIFIED FINAL CONTROL ELEMENT

POSITION

EQUIPMENT LIST

SOLENOID ACTUATORS

PRESSURE SAFETY VALVE:

VACUUM RELIEF VALVE:

S

S

S

2-WAY SOLENOID WITH SINGLE ACTUATOR

3-WAY SOLENOID WITH SINGLE ACTUATOR

S R

SOLENOID VALVE LOCAL MANUAL RESET WHEN INITIATED

barg

PSV SET@ IN: ORIFICE: OUT:

VALVE NUMBER SET PRESSURE INLET:SIZE-RATING-FLG. TYPE ORIFICE TYPE OUTLET:SIZE-RATING-FLG.TYPE

barg

PSV SET@ IN: ORIFICE: OUT:

VALVE NUMBER VACUUM RELIEF INLET:SIZE-RATING-FLG. TYPE ORIFICE TYPE OUTLET:SIZE-RATING-FLG.TYPE

SELF ACTUATED REGULATOR

PRESSURE & VACUUM SAFETY VALVE:

PRESSURE-REDUCING VALVE (SELF-CONTAINED)

PRESSURE-REDUCING VALVE WITH EXTERNAL PRESSURE TAP

BACK-PRESSURE VALVE (SELF-CONTAINED)

BACK-PRESSURE VALVE WITH EXTERNAL PRESSURE TAP

LCV

barg

PSV SET@ IN: ORIFICE: OUT:

VALVE NUMBER SET PRESSURE INLET:SIZE-RATING-FLG. TYPE ORIFICE TYPE OUTLET:SIZE-RATING-FLG.TYPE

RUPTURE DISKS:

RD- BARG

RUPTURE DISK NUMBER BURST PRESSURE

T

STEAM TRAP - BALL FLOAT TYPE

PRESSURE

VACUUM

1

0

IFH–Issued for HAZOP

25/Jun/2024

IFA-Issued for Approval

K.Jeetu

K.Jeetu

A.Lo Verso/G.Acerbi/ E.Magadeev/ H.Aljarrah

A.Lo Verso/G.Acerbi/ E.Magadeev/ H.Aljarrah

A.Lo Verso

A.Lo Verso

 Realisation en EPC d'installations de production de

LINEAR-ALKYL-BENZENE <> a SKIKDA ALGERIE CT-EPC/017/SH/EPM/RPC-X/2023 CT-EPC/017/SH/EPM/RPC-X/2023

PIPING & INSTRUMENTATION DIAGRAM GENERAL NOTES, SYMBOL AND LEGEND PIPING SYMBOLS 3