4439 VZ DM 0000 0012_1

I

T N E S N O C N E T T R W R O R P T U O H T W

I

I

,

E S O P R U P Y N A R O F S R E H T O Y B D E S U E B T O N N A C D N A Y T R E P O R P S T N O M N C E T S

I

’

I

T N E M U C O D S H T

I

DETAIL “D”

TYPICAL DETAIL OF PRESSURIZED DUAL (DOUBLE) MECHANICAL SEAL FLUSHING TO PUMPS

L

FI

FT

FG

B1A1

5 °C

PG

3/4” FLUSH FROM PUMPS

FIF MUST BE READABLE FROM VALVE

INBOARD SEAL

PUMP SHAFT

OUTBOARD SEAL

TO SEAL CHAMBER

B1A1

5 °C

3/4” FLUSH TO PUMPS: (EACH SEAL SHALL HAVE ITS OWN INDEPENDENTLY CONTROLLED FLUSH SUPPLY)

DETAIL “DM” PRESSURIZED DUAL (DOUBLE MECHANICAL) SEAL FLUSH SYSTEM

(FURNISHED BY PUMP SUPPLIER)

1” SILICONE

NITROGEN

3/4”

3/4”

SEAL POT

PI

LI

L

L

FREE DRAINING

2

I

I

G N N A R D E E R F

PUMP SEAL SYSTEM DETAILS

DETAIL “DC”

DUAL (DOUBLE) SEAL FLUSHING SYSTEM

                ID PIPING SHALL BE OF THE SAME

METALLURGY TYPE AND CLASS AS SHOWN AT THE PUMP.

DETAIL “DD”

DRY NON-CONTACTING PRESSURIZED DUAL (TANDEM) SEAL FLUSHING SYSTEM

       VALVES AND PIPING SHALL BE OF THE SAME

METALLURGY TYPE AND CLASS AS SHOWN AT THE PUMP

GENERAL NOTES:

3/4” WATER (MIN)

MS-1

5 °C

NITROGEN

1

7

7

1

7

FT

FI

FG

H

L

1

DRY GAS SEAL CONTROL PANEL

FI

PI

H

L

C ° 5

3/4”

3/4”

OWS

DETAIL “FA”

PRESSURIZED DUAL SEAL FLUSHING SYSTEM (FURNISHED BY PUMP SUPPLIER)

(PIPE CLASSES BY CONTRACTOR)

DETAIL “FB”

PRESSURIZED DUAL SEAL FLUSHING SYSTEM (FURNISHED BY PUMP SUPPLIER)

3..

NOTES:

VENT FROM OTHER SEAL POT(S) (AS REQUIRED).

DRAIN FROM OTHER SEAL POT (AS REQUIRED).

THERE ARE FIVE CLOSED DRAIN SYSTEM (CD) FOR STREAMS COMING FROM UNIT 100/200/300 (CDA) FOR STREAMS COMING FROM UNIT 400/500/600 (CDB) FOR STREAMS COMING FROM BENZENE STORAGE (CDD) FOR STREAMS COMING FROM UNIT 700 (CDF) FOR STREAMS COMING FROM FLARE UNIT SELECTION OF CRITERIA FOR REQUIREMENT FOR CLOSED DRAIN IS AS PER UOP CRITERIA AND ALSO FOR STREAMS CONTAINING >12.5% OR MORE C7 THRU C9 AROMATICS THEY ALSO NEED TO GO TO A CLOSED DRAIN SYSTEM.

  1. MAKE CONNECTION ON TOP OF PIPE.

FURNISHED WITH PUMP.

  1. PROVIDE WHEN MAKEUP BARRIER FLUID IS HARD-PIPED.

PROVIDE FOR EACH SEAL (FURNISHED WITH PUMP).

NITROGEN

PG

PG

PRESSURE REGULATOR

5

SEAL POT

PI

LI

L

L

1

1 1/2” MAKEUP BARRIER FLUID

6

6

1

3/4”

1

6

5

SEAL POT

LI

L

HOLDS:

COOLING WATER RETURN

COOLING WATER SUPPLY

EQUIPMENT LIST

3

COOLING WATER RETURN

COOLING WATER SUPPLY

DETAIL “E”

EXTERNAL PRESSURIZED BARRIER FLUID SEAL LUBRICATION SYSTEM FOR API PLAN 54 (FURNISHED BY PUMP SUPPLIER)

PRESSURIZED SEAL LUBRICATION SYSTEM SKID (ONE REQUIRED FOR EACH PUMP)

TI

LI

PI

H

H

L

L

COOLING WATER RETURN

COOLING WATER SUPPLY

1

0

11/Oct/2024

IFH–Issued for HAZOP

25/Jun/2024

IFA-Issued for Approval

K.Jeetu

K.Jeetu

A.Lo Verso/G.Acerbi/ E.Magadeev/ H.Aljarrah

A.Lo Verso/G.Acerbi/ E.Magadeev/ H.Aljarrah

A.Lo Verso

A.Lo Verso

 Realisation en EPC d'installations de production de

LINEAR-ALKYL-BENZENE <> a SKIKDA ALGERIE CT-EPC/017/SH/EPM/RPC-X/2023 CT-EPC/017/SH/EPM/RPC-X/2023

PIPING & INSTRUMENTATION DIAGRAM GENERAL NOTES, SYMBOL AND LEGEND PIPING SYMBOLS 12

4439-VZ-DM-0000-0012

A1

Echelle :

1/1

1 of 1