Project: Q-TEST-2 | Customer/EPC: NMDC | Date: 2025-08-13 To: EPC Buyer Subject: Request for Information — Q-32859 Ruwais LNG

Items

  • Topic: Standards Baseline & Test Scope
    • Observation: Instrumentation baseline and explicit test scope (IFAT/CIT/SIT) not present in current subset.
    • Evidence: Quote Rev.1 Note - Compliance.md indicates time constraints.
    • Question: Please confirm applicable instrumentation/testing standards and inclusion of FAT/SAT/IFAT/CIT/SIT in scope.
  • Topic: Hazardous Area Class/T‑class (per component)
    • Observation: Offered classification per component (switches/alarms/JBs) not explicit in subset.
    • Evidence: Offer Q-32859-1.md; Chiller datasheet Q-32859 Chiller Datasheet.md.
    • Question: Please confirm class/T‑class for each component and provide certificates.
  • Topic: Ingress Protection
    • Observation: IP ratings by subcomponent (motors/instruments) not fully explicit.
    • Evidence: Offer Q-32859-1.md; Chiller datasheet.
    • Question: Please confirm IP for all external components meeting site requirements.
  • Topic: Quantity Reconciliation
    • Observation: MR not included in shared subset.
    • Evidence: Offer Q-32859-1.md.
    • Question: Please provide MR totals or confirm offered quantities by category.