Hazardous‑Area Component Matrix — Q-21699 (Saipem COMP2)

ComponentArea Class (Zone)Gas GroupT‑ClassProtection Concept (decided)Evidence (Doc + lines)EP Item_IDStatus
Tank Shower Assembly (EXP‑MH‑14KS/1500)Zone 1/2IIA/IIB (IIC available)T3FLP selected — Ex dReference Examples/Q-21699 - Saipem COMP2/Rev 1 Quote Sent/Datasheets and CoCs.md, lines 212–218; 468–471 • Reference Examples/Q-21699 - Saipem COMP2/RFQ Files/Instrumentation/200-51-IN-SPC-00021_00.md, lines 1771–1780EP‑002Pending Evidence — Variant locked (FLP Ex d); attach ATEX/IECEx CoCs (RFI‑FLP/BOM)
Immersion HeaterZone 1/2IIA/IIB (IIC option)T3Ex d (per spec default for field instruments)Reference Examples/Q-21699 - Saipem COMP2/RFQ Files/Instrumentation/200-51-IN-SPC-00021_00.md, lines 1771–1780Pending Evidence — Vendor heater Ex certificate required (RFI‑FLP/BOM)
Junction Box (JB)Zone 1IIB min per specT3Ex d (per spec default)Reference Examples/Q-21699 - Saipem COMP2/RFQ Files/Instrumentation/200-51-IN-SPC-00021_00.md, lines 1771–1780Pending Evidence — Provide JB Ex d certificate + IP66/67 proof (RFI‑IP + RFI‑FLP/BOM)
Sign/Light Box (if provided)Zone 1IIBT3Ex d (pending vendor confirmation)Spec 200-51-IN-SPC-00021_00, lines 1771–1780; Datasheets pack — no detailPending Evidence — Provide cert + IP66 evidence (RFI‑IP)
Local Control/TerminalsZone 1IIBT3Ex d (per spec default)Spec 200-51-IN-SPC-00021_00, lines 1771–1780Pending Evidence — Vendor to confirm

Weakest‑Link Assessment

  • With variant locked (FLP Ex d) and power decision addressed in Decision Table, the current weakest links are (a) missing IP66/67 certificates for field enclosures (JB/sign box/chiller) and (b) EMC/ATEX register not attached.
  • Flag: weakest_link_flag == true.