RFQ at a Glance — Q-32705 (Saipem COMP3)
Client_Profile: Other (Qatar Energy; Saipem EPC)
Anchors
- Offer:
example-documentation-md/Q-32705 - Saipem COMP3/Q-32705-1 Priced Commercial Offer.md
- Datasheets: Tank —
example-documentation-md/Q-32705 - Saipem COMP3/Safety Shower Datasheet EXP-MH-14KS-1500.md
; Chiller —example-documentation-md/Q-32705 - Saipem COMP3/Chiller Unit Datasheet Zone-1.md
- Project Specs (EMC/IP/Power):
example-documentation-md/Q-32705 - Saipem COMP3/RFQ Files/200-51-IN-SPC-00054_00.md
,.../200-91-EL-SPC-00034_B.md
,.../200-91-EL-SPC-00031_B.md
Counts & Complexity
- Files reviewed: 4 primary (offer + 2 datasheets + 1 spec), 3 auxiliary specs queued
- Complexity: M (cross‑references across EPC specs; no single MR)
Key Claims (evidence)
- Tank DS: ATEX Zone 1 & 2; IIA/IIB; T3; 240V 1Φ (lines 105–111)
- Chiller DS: ATEX Zone 1; Ex II 2G IIB T4; IP66; 220‑240V 1Φ or 380‑420V 3Φ (lines 52–67; 60)
- Offer: “Electrical items suitable for Zone 2, Instrumentation suitable for Zone 1. IIB T3.” and dual supplies (lines 46–52)
Missing Docs / Integrity
- No MR; rely on EPC specs. Validate if a package MR exists. If not, specs above are the governing references.
TQ/RFI Candidates
- Confirm power topology: Offer states separate 230V 1Φ for heater and 3Φ for chiller (offer lines 50–52). EPC drawings show 230/240V 1Φ prevalent; confirm acceptance of dual feeds.
- Confirm IIC requirement: Datasheet offers IIC available; EPC lights list shows IIC occurrences; clarify if IIC mandated for this package.
Next Best Action
- Proceed to CF02 extraction for HazArea/EMC/IP/Power, then curator view of High‑Risk.