Deviation Report — Draft (Q 32705, Saipem COMP3)

Deviation Report — Draft (Q-32705, Saipem COMP3)

Dev_IDSource Requirement (verbatim + source)Offered Provision (quote + page/line)JustificationImpactProposed Client WordingCPQ Implication
D-001”ATEX Zone 1 & 2. Gas groups IIA & IIB. Temp Class T3 (IIC available)” (Safety Shower Datasheet EXP‑MH‑14KS‑1500, lines 105–111)Configure IIC variants across assembly if IIC mandated by EPC; chiller DS is EX II 2G IIB T4 (lines 52–56).Aligns to EPC IIC occurrences where required; maintain end‑to‑end classification coherency.Cost/schedule only if IIC variant required”For units in IIC service, supply IIC‑certified components across assembly; provide matching IECEx/ATEX certificates.”Select IIC‑certified components where required
D-002Power topology acceptance (EPC utilities generally 230/240V 1Φ; 3Φ available)Offer specifies separate 230V 1Φ heater feed and 3Φ chiller feed (Q‑32705‑1, lines 50–52).Standard packaged integration; avoids additional internal distribution.None (topology confirmation)“Accept separate external feeds: 230/240V 1Φ for heater; 3Φ for chiller.”None