Deviation Report — Draft (Q-32705, Saipem COMP3)
Dev_ID | Source Requirement (verbatim + source) | Offered Provision (quote + page/line) | Justification | Impact | Proposed Client Wording | CPQ Implication |
---|
D-001 | ”ATEX Zone 1 & 2. Gas groups IIA & IIB. Temp Class T3 (IIC available)” (Safety Shower Datasheet EXP‑MH‑14KS‑1500, lines 105–111) | Configure IIC variants across assembly if IIC mandated by EPC; chiller DS is EX II 2G IIB T4 (lines 52–56). | Aligns to EPC IIC occurrences where required; maintain end‑to‑end classification coherency. | Cost/schedule only if IIC variant required | ”For units in IIC service, supply IIC‑certified components across assembly; provide matching IECEx/ATEX certificates.” | Select IIC‑certified components where required |
D-002 | Power topology acceptance (EPC utilities generally 230/240V 1Φ; 3Φ available) | Offer specifies separate 230V 1Φ heater feed and 3Φ chiller feed (Q‑32705‑1, lines 50–52). | Standard packaged integration; avoids additional internal distribution. | None (topology confirmation) | “Accept separate external feeds: 230/240V 1Φ for heater; 3Φ for chiller.” | None |