Hazardous-Area Component Matrix — Q-32859

Client_Profile: ADNOC

ComponentClaimed Area ClassGas GroupT‑ClassEvidence (doc+line)
Tank Shower Electrical/Instr. (base)Zone 1 & 2IIA/IIB (IIC available)T3Datasheet EXP‑MH‑14KS/1500, lines 105–111
Chiller Unit (package)Zone‑1IIBT3Chiller Datasheet, lines 103–105
Chiller Control Panel IP———IP66 (panel) — Chiller Datasheet, line 116
Chiller Instruments IP———IP65 (instruments) — Chiller Datasheet, line 116
Chiller Pump Motor IP———IP55 (motor) — Chiller Datasheet, line 117
Proximity Switch(es)Zone 1 & 2IIA/IIB—Offer Q‑32859‑1 p.2, lines 156–169
SS316 Junction Box (alarm)Zone 1——Offer Q‑32859‑1 p.2, lines 173–181
SS316 Junction Box (heater/light)Zone 1——Offer Q‑32859‑1 p.2, lines 200–211

Weakest‑Link Consolidation (per unit)

  • Area Class: For non‑H₂ service, Zone‑1 IIB T3 via chiller. For H₂ service, configure IIC T3 end‑to‑end (tank shower IIC variant + chiller certification to be matched in submittals).
  • IP Baseline: IP55 due to pump motor; check MR minimums for instruments/motors; deviation only if motor IP65 mandated.

Auto‑Flags

  • Weakest_Link_Flag: TRUE (Area Class = IIB via chiller for non‑H₂; IIC configured for H₂; IP weakest = IP55 motor).
  • Dual Power: TRUE candidate — Offer indicates 415 VAC 3Φ chiller plus 230/240 VAC shower feed (Offer p.4 lines 364–366; Datasheet lines 109–113).