“All cable glands shall be IP65 according to IEC 60529. All junction boxes shall be in stainless 316L SS with a minimum ingress protection code IP65 according to IEC 60529.” (4439-SS-SS-008006_0, §9.5, lines 1250–1257)
Partial
EXP-MH-14KS-1500; FLP Chiller
116–123; 72
EP-EL-001; EP-SPEC-001 (Parked)
Validate outdoor IP66 if required by project baseline; ensure JB/signage at or above min.
R-0002
“… all field instruments … shall be certified to ATEX and suitable for Zone 2, Gas Group IIC, T1, as minimum.” (4439-SS-SS-008006_0, §9.1, lines 1062–1066)
Partial
EXP-MH-14KS-1500
116–121
EP-ATEX-001/002/003 (Parked)
Lock component protection concept Ex d/e/tb; collect declarations/certs.
R-0003
“ATEX Zone 1 & 2. Gas groups IIA & IIB. Temp Class T3 (IIC available). Non-flameproof models also available. 240V, single phase, 50/60Hz (110V optional).” (EXP-MH-14KS-1500 Datasheet, lines 116–123)
Pending
EXP-MH-14KS-1500
116–123
—
Decision: variant_locked = true (FLP Ex d selected); power_decided = true (240V 1Ph 50/60Hz).
R-0004
“INGRESS PROTECTION … IP 66 … ELECTRICAL POWER SUPPLY … 220–240V/1Ph/50hz … 380–420V/3Ph/50hz or 440–480V/3Ph/60h.” (Optional flameproof_chiller_zone_1.md, lines 72; 75–80; 267–275)
Partial
FLP Chiller Unit
72; 75–80; 267–275
EP-ATEX-001/002 (Parked)
If included, ensure CPQ covers chosen power variant and Ex d JB/signage.