Hazards Component Matrix — Q-32976

ComponentArea Class (Zone)Gas GroupT‑ClassProtection Concept (Ex d/e/tb/other)Evidence (Doc + lines)EP Item_IDStatus (Compliant/Partial/RFI)Notes
Tank Shower AssemblyZone 1/2IIB (IIC available)T3Ex d (variant)Reference Examples/Q-32976 - Tecnmont SKIKDA/Datasheet with GAD - EXP-MH-14KS-1500.md, lines 116–123; 440–442EP-ATEX-001/002 (Parked)PartialVariant must be locked (FLP vs non‑FLP)
Immersion HeaterZone 1/2IIB (IIC available)T3Ex d (heater)Reference Examples/Q-32976 - Tecnmont SKIKDA/Datasheet with GAD - EXP-MH-14KS-1500.md, lines 116–123EP-ATEX-001/002 (Parked)PartialConfirm Ex certificate for heater element
Junction Box (local)Zone 1/2IIB/IICT?Ex e or Ex dReference Examples/Q-32976 - Tecnmont SKIKDA/RFQ Files/4439-SS-SS-008006_0.md, lines 1250–1257EP-ATEX-003 (Parked)RFISpec demands IP65 min; need Ex cert and IP proof
Sign/Light BoxZone 1/2IIB/IICT?Ex d (if alarm)EP-ATEX-003 (Parked)RFIIf included, ensure Ex rating and IP66
Flameproof Chiller (optional)Zone 1IIBT4Ex dReference Examples/Q-32976 - Tecnmont SKIKDA/Optional flameproof_chiller_zone_1.md, lines 66–80; 72EP-ATEX-001/002 (Parked)PartialIP66; dual power variants

Weakest‑Link

  • Current weakest_link_flag: true — Pending confirmation of JB/signage Ex/IP; ancillary must not fall below IP65/Zone class.
  • Variant dependency: variant_locked required (FLP Ex d path vs non‑FLP).